INSTALLATION INSTRUCTIONS
For Juno Trac Adapter*

WARNING Read all of these installation instructions before installing.
SAVE THESE INSTRUCTIONS

FIXTURE INSTALLATION Step 1 Find the latch and the polarity line. Align parts as shown and insert the adapter box into the track. (Fig. 1)

Fig. 1
LATCH

POLARITY LINE

Fig. 2

Coming Soon

Step 2 Pull down the latch while rotating the adapter box 90 degrees clockwise. (Fig. 2)

Step 3 Final Position: Latch snaps into place between extrusion rails. Arrows on latch point toward the polarity line. (Fig. 3)

Fig. 3

SECOND CIRCUIT POSITIONING
Step 1 Raise the contact marked "P" (on switch side) by inserting a thin screwdriver blade under contact. Pull up into position as shown. (Fig. 4)

(INSERT)

(PULL)

(ROTATE)

Fig. 4
"P" CONTACT

(LIFT)

Step 2 Insert contact support (supplied with 2-circuit Trac section) by tilting and snapping into position under the "P" contact as shown. (Fig. 5)

Fig. 5

Step 3 Ensure contact support is snapped and locked into position. (Fig. 6) Follow instructions for inserting into track.

CONTACT SUPPORT

Fig. 6

FINAL POSITION OF CONTACT SUPPORT

*Juno Trac adapter size and style may vary.

One Lithonia Way · Conyers, GA 30012 · 1-800-705-SERV (7378) · www.acuitybrands.com

©2020 Acuity Brands Lighting, Inc.

P6300 Rev 10/2022

1 of 2

Coming Soon

INSTALLATION INSTRUCTIONS
For Juno Trac Adapter*

TROUBLESHOOTING

Problem
Fixture doesn't turn on

Cause Track not energized Adapter switch is in the
"Off" position
Fixture installed incorrectly

Remedy Ensure track has power
Ensure the power switch on the track fixture adapter is in the "On" position, see Fig. 9
Ensure fixture is installed correctly, with the arrows on the latch pointing towards the polarity line as shown in Fig. 3
Ensure contacts aren't bent from installing the fixture incorrectly, see Fig. 7

Fig. 7

"P" Contact adjusted incorrectly

Ensure "P" contact isn't bent from adjusting incorrectly, see Fig. 8
Bent contact from adjusting the wrong contact, see Fig. 4, 5, & 6 for proper adjustment method

Correct

Single Circuit Position
Used with T, TU, and R Series Track

Incorrect

Bent Contact

Raised Contact

Fig. 8

Correct

Two Circuit Position
Used with TU Series Track

Incorrect

Bent Contact

Raised Contact

Fig. 9

Move Switch To "On" Position

Off

On

One Lithonia Way · Conyers, GA 30012 · 1-800-705-SERV (7378) · www.acuitybrands.com