AKIMist Dry Fog Humidifying System Hanging-Down (NP) Kit Installation Manual

Instruction Manual

OIL-FREE HANGING-DOWN (NP) KIT (WITHOUT PLATE)

for AKIMist® Dry Fog Humidifying System

Thank you for purchasing AKIMist Humidifier with Hanging-down (NP) Kit (w/o plate). To properly use the installation kit, please read this instruction manual.

Check the contents of the box.

Contents:

  • AKIMist with connection kit
  • AKIMist Instruction Manual
  • and this manual

Parts Description

For order of spare parts, use specific description and code number below.

Diagram showing the components of the Hanging-Down (NP) Kit. Numbered parts correspond to the table below, illustrating valves, regulators, couplers, and tubing fittings. The diagram shows a central manifold with connections for air and water lines, featuring red and blue valves, a pressure regulator with a gauge, various couplers, and tube fittings.
Section Part No. Description Material* Code No.
Air Line 1 Valve (Red) S304 #289481
2 Pressure Regulator (with pressure gauge) POM, aluminum #265941
3 Male-female Socket #115787
4 Coupler (Socket) #193606
5 Coupler (Plug) #12234
Water Line 6 Valve (Blue) S304 #289482
7 Socket S304 #147408
8 Tube Fitting (Elbow) #130693
9 Tube Nylon #18582
10 Tube Fitting (Elbow) #130693
11 Liquid Coupler (Socket) Polyacetal #157467
12 Liquid Coupler (Plug) S303 #216627

*Materials S303/S304/S316's "S" means stainless steel in this manual.

Note: Parts No.5 and No.12 are provided in the AKIMist humidifier, not in the kit.

How to Install

The valves of this kit are Rc 1/4" (1/4 female) threaded. Please prepare R 1/4 threaded joints on the pipe side.

⚠️ Caution

  • Connect the air pipe and water pipe correctly.
  • Be careful not to drop anything during installation at high places.
  • For inquiry/order, use the specific part name and code number on the previous page.

The part numbers mentioned in the instructions below correspond to the parts listed on the previous page.

  1. Disconnect air couplers (socket #4 from plug #5) and liquid couplers (socket #11 from plug #12). To disconnect the liquid couplers, push the black cover (sleeve) of the socket (#11) down towards the plug (#12) as shown in Figure 1.
  2. Connect air and water tubes to valves (#1 and #6) respectively. Rc 1/4" threaded connection for both air and water. (Recommended torque: 15 N-m)
  3. Connect air and water couplers respectively. Insert each plug into each socket until it clicks. For liquid couplers, push the coupler into the black cover part until it clicks into place. The joint part will be hidden under the black cover (see Figure 2).
  4. Open valves (#1 and #6) and set the air pressure with pressure regulator (#2).
Figure 1 illustrates the disconnection of a liquid coupler. It shows a black sleeve on the socket being pushed downwards to release the plug.
Figure 2 shows a connected joint part for liquid couplers. The connection is secured and hidden beneath the black sleeve of the socket.

For installation and operation of AKIMist, refer to the enclosed Instruction Manual for AKIMist Dry Fog Humidifier.