Owner's Manual for MEAN WELL models including: NTS-300 series, NTS-300 series 300W High Reliable True Sine Wave Inverter, NTS-300 series, 300W High Reliable True Sine Wave Inverter, High Reliable True Sine Wave Inverter, True Sine Wave Inverter, Sine Wave Inverter, Wave Inverter, Inverter

NTS-300-20241030

wangj

NTS-300 series

[PDF] NTS-300 series - MEAN WELL

NTS-300 is a 300W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined ...


File Info : application/pdf, 8 Pages, 2.23MB

PDF preview unavailable. Download the PDF instead.

NTS-300-spec
300W High Reliable True Sine Wave DC-AC Power Inverter DC input side

NTS-300 series

User's Manual

Video

AC output side

E13

IEC62368-1 CSA/UL62368-1 BS EN/EN62368-1 Please refer to page3 for more details.
 Features

TPTC004 AS/NZS 62368.1

 Applications

Compact size and light weight

Mobile device

True sine wave output (THD<3%)

Home and office appliance

High surge power up to 600W

Power tools

Fanless design

Portable equipment

AC output voltage and frequency selectable by DIP S.W

Vehicle

No load disspation <1.5W max. at standby saving mode

Yacht

-25~+65 wide operating temperature Power ON-OFF remote control

Off-grid solar power system Wireless network

Front panel indicator for operation status

Telecom or datacom system

Protections :

Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage

Output : Short circuit / Overload / Over temp. Battery over discharge protection(Low voltage disconnect) Suitable for lead-acid or li-ion batteries

 GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Carry handle accessory available(Order NO.: Carry handle, sold separately)

Conformal coating

3 years warranty

 Description
NTS-300 is a 300W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, 600W peak power, adjustable AC output voltage and frequency, -25~+65 wide operating temperature range, complete protections features, and etc. combined with batteries, the NTS-300 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.

 Model Encoding
NTS - 300 - 1 12 US
AC output socket (Type US, EU, CN, AU, UK, UN, GFCI outlet) DC input voltage (12: 12Vdc, 24: 24Vdc, 48: 48Vdc) AC output voltage (1: 100/110/115/120Vac, 2:200/220/230/240Vac) Rated wattage Series name
File Name:NTS-300-SPEC 2024-11-25

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 series

SPECIFICATION

MODEL NO.

NTS-300-112 NTS-300-124 = US, GFCI, UN

NTS-300-148

NTS-300-212 NTS-300-224 = EU, CN, AU, UK, UN

NTS-300-248

RATED POWER(Continuous) 300W

OVER RATED POWER(3 Min.) 345W

PEAK POWER(10 Sec.)

450W

SURGE POWER(30 Cycles) 600W

AC VOLTAGE AC OUTPUT
FREQUENCY WAVEFORM AC REGULATION

Default setting set at 110VAC 100 / 110 / 115 / 120Vac selectable by DIP S.W Default setting set at 60Hz±0.1Hz 50/60Hz selectable by DIP S.W Note.1 True sine wave (THD<3%) ±3.0% at rated output voltage

Default setting set at 230VAC 200 / 220 / 230 / 240Vac selectable by DIP S.W Default setting set at 50Hz±0.1Hz 50/60Hz selectable by DIP S.W

FRONT PANEL LED

Please refer to page5

DC VOLTAGE

12V

24V

48V

12V

24V

48V

VOLTAGE RANGE (Typ.)

10 ~ 16.5Vdc

20 ~ 33Vdc

40 ~ 66Vdc

10 ~ 16.5Vdc

20 ~ 33Vdc

40 ~ 66Vdc

DC INPUT

DC CURRENT (Typ.)

30A

15A

8A

30A

15A

8A

NO LOAD NON-SAVING MODE 10W

10W

12W

10W

10W

12W

DISSIPATION

(Typ.)

SAVING MODE

Default disable, 1.2W ~ 1.5W by models @ auto detec AC output load 10W will be changed to saving mode

1.2W

1.3W

1.5W

1.2W

1.3W

1.5W

OFF MODE CURRENT DRAW 1mA

EFFICIENCY (Typ.) Note.1 90%

92%

92%

92%

93%

93%

BATTERY TYPES

Lead Acid or li-ion

DC INPUT

FUSE (Internal)

ALARM

LOW

SHUTDOWN

RESTART

ALARM

HIGH

SHUTDOWN

RESTART

BAT. POLARITY

30A*2

30A*1

11±0.3Vdc

22±0.5Vdc

10±0.3Vdc

20±0.5Vdc

12.5±0.3Vdc

25±0.5Vdc

15.5±0.3Vdc

31±0.5Vdc

16.5±0.3Vdc

33±0.5Vdc

15±0.3Vdc

30±0.5Vdc

By internal fuse open

10A*2 44±1Vdc 40±1Vdc 50±1Vdc 62±1Vdc 66±1Vdc 60±1Vdc

30A*2 11±0.3Vdc 10±0.3Vdc 12.5±0.3Vdc 15.5±0.3Vdc 16.5±0.3Vdc 15±0.3Vdc

30A*1 22±0.5Vdc 20±0.5Vdc 25±0.5Vdc 31±0.5Vdc 33±0.5Vdc 30±0.5Vdc

10A*2 44±1Vdc 40±1Vdc 50±1Vdc 62±1Vdc 66±1Vdc 60±1Vdc

PROTECTION

OVER TEMPERATURE

Protection type : Shut down o/p voltage, re-power on to recover

AC OUTPUT

OUTPUT SHORT

Protection type : Shut down o/p voltage, re-power on to recover

OVER LOAD (Typ.)

105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover

GFCI PROCTECTION

Design refer to UL458 (Only for "GFCI" AC socket , by request)

None

FUNCTION REMOTE CONTROL WORKING TEMP. WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY

Power ON-OFF remote control by front panel dry contact connector (by RELAY); Open : Normal work ; Short ,Remote off -25 ~ +65(Refer to "Derating curve") 20% ~ 90% RH non-condensing -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH non-condensing

VIBRATION

10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

CB IEC62368-1,CSA/UL62368-1,Dekra BS EN/EN62368-1,E13,EAC TP TC 004 approved;Design refer to AS/NZS 62368.1 (Please refer to next page"AC output socket" table for more details) ; Design refer to UL458(By request)

WITHSTAND VOLTAGE

DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac

Parameter

Standard

Test Level / Note

SAFETY &
EMC
(Note.4)

EMC EMISSION

Radiated

FCC for 112,124,148 only(expect for Type-UN)

Class A

BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) Class A

Harmonic Current BS EN/EN61000-3-2

-----

Voltage Flicker

BS EN/EN61000-3-3

-----

BS EN/EN55024, BS EN/EN55035

Parameter

Standard

Test Level / Note

EMC IMMUNITY

ESD Radiated

BS EN/EN61000-4-2 BS EN/EN61000-4-3

Level 3, 8KV air ; Level 2, 4KV contact Level 2, 3V/m

OTHERS

MTBF DIMENSION PACKING

Magnetic Field

BS EN/EN61000-4-8

845.6K hrs min. Telcordia TR/SR-332 (Bellcore) ;

210*130*55mm (L*W*H)

1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT

85.3K hrs min.

Level 1, 1A/m MIL-HDBK-217F (25)

NOTE

1.Efficiency, AC regulation and THD are tested by 300W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage. 2.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting. 3.Internal pre-start circuit, the setup time is 8s. 4.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

 Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:NTS-300-SPEC 2024-11-25

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 series

AC Output Socket
MODEL NO. NTS-300-112 NTS-300-124 NTS-300-148

NTS-300-212

NTS-300-224

NTS-300-248

Socket type Country Certificate

TYPE-US In Stock
USA

TYPE-GFCI By request
USA

TYPE-UN In Stock UNIVERSAL

TYPE-EU In Stock EUROPE

TYPE-CN In Stock CHINA

None

E13

TYPE-UK By request
U.K

TYPE-AU By request AUSTRALIA
E13

TYPE-UN In Stock UNIVERSAL
E13

LOAD (%)

DERATING CURVE
100 80 50 40

-25

0

10

20

30

40 50 60

65 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100 80 60 40 20

10Vdc 20Vdc 40Vdc

10.5Vdc 21Vdc 42Vdc

16.5Vdc 33Vdc 66Vdc

File Name:NTS-300-SPEC 2024-11-25

LOAD (%)

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 series

Remote ON-OFF Control

Remote ON-OFF Open Short

AC Output Status power inverter ON power inverter OFF

AC Output VoltageFrequencyPower saving mode selectable by DIP SW Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.
Status DC input Load R.C SW
1 2
Type-US

AC OUTPUT

AC Output Voltage FrequencyPower saving mode selectable by DIP SW

SW1 SW2

SW3

SW4

OFF OFF : 100Vac or 200Vac OFF ON : 110Vac or 220Vac

ON : 50Hz

ON : Saving mode

ON OFF : 115Vac or 230Vac ON ON : 120Vac or 240Vac

OFF: 60Hz

OFF: Non-Saving mode

File Name:NTS-300-SPEC 2024-11-25

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 series

LED STATUS Normal work:
Status
DC Input
Load
Abnormal status : LED Indicator Status DC Input Load Status DC Input Load Status DC Input Load Status DC Input Load Light Light off Flash

Green System check Inverter OK
Green 12.5~15.5Vdc 25~31Vdc 50~62Vdc
Green <40% load

Orange Remote off Saving mode
Orange 11~12.5Vdc 22~25Vdc 44~50Vdc
Orange 40~80% load

Abnormal Indication Output overload or AC output short circuit

Abnormal DC voltage

Over temperature or Fan lock Inverter fail

Red
Abnormal Status
(See below table)
Red <11Vdc or >15.5Vdc <22Vdc or >31Vdc <44Vdc or >62Vdc
Red >80% load

File Name:NTS-300-SPEC 2024-11-25

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 series

MECHANICAL SPECIFICATION
(Unit: mm , tolerance ± 1mm)

210

55

45

120

Case No. 282A

ON
OFF
Chassis Bonding Lug

16 9
119 130

DC INPUT
- +
Reverse Polarity Will Damage The Unit.
(DC input side)

AC OUTPUT

AC OUTPUT

7

Status DC input Load R.C SW
1 2
Status DC input Load R.C SW
1 2

Type-EU Type-CN

AC OUTPUT

AC OUTPUT

Status
DC input Load
R.C SW
1 2

Type-US

Status DC input Load R.C SW
1 2
(AC output side)

Type-UN

R.C Connector : JST B-XH or equivalent

Remote Control

Mating Housing

Pin 1,2 Open: Normal work Pin 1,2 Short: Remote off

JST XHP or equivalent

Terminal
JST SXH-001T or equivalent

File Name:NTS-300-SPEC 2024-11-25

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 series

Accessory List
 Carry handle (Optional accessory, Power inverter and Pull handle should ordered seperately)

MW's Order No.

Item

Quantity

1

Handle

Carry Handle

2 Foot pad

27mm

1

10mm

180mm

4

1 Handle

3 Screw

2 M4*2

2 Foot pad

File Name:NTS-300-SPEC 2024-11-25

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 series

TYPICAL APPLICATION

3 2
1

5

4

3

1 Battery Bank 2 Off-Grid DC/AC Solar Inverter (NTS series) 3 AC Outlet

1 Utility Input (Shore)

2 AC/DC Battery Charger (PB/NPB/NPP series)

3 Battery Bank

4 Off-Grid DC/AC Power Inverter (NTS series)

2

1 5 AC Outlet

4 4

2

3

4

1

INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html

1 AC/DC Battery Charger (PB/NPB/NPP series) 2 Battery Bank 3 Off-Grid DC/AC Inverter (NTS series) 4 AC Outlet
File Name:NTS-300-SPEC 2024-11-25



References

Acrobat Distiller 9.0.0 (Windows)