Owner's Manual for SUNCO LIGHTING models including: T8, T8 LED Tube Light with Emergency Battery, LED Tube Light with Emergency Battery, Tube Light with Emergency Battery, Light with Emergency Battery, Emergency Battery, Battery
T8 LED Tube with Emergency Battery, 4ft, Clear, Bypass, Type B, 18W, D – Sunco Lighting
Installation Guides, Manuals, and Specs | Sunco – Sunco Lighting
EMERGENCY TUBE LIGHT In the Charging Full Battery Test Emergency Function Button Hidden Switch Button FEATURES · Emergency tube over 120mins, AC input voltage (100-277VAC) · A grade ternary lithium battery, 2*2.6Ah 3Ah, 3.7V Ultralong emergency time limit, minimum level 2 hours · Built-in certified emergency driver, lifespan, high safety performance · With automatic monthly inspection function, fault alarm function, more intelligent · With emergency test button/indicator/battery power switch, appearance coordination, beautiful and textured · Emergency brightness over 1100lm, meets most office demands SUITABLE APPLICATIONS · Office lighting · Meeting room lighting · Store lighting · Restaurant lighting DESCRIPTION: The Emergency LED Tubes can work directly plug and play with old tube fixtures, emergency time over 120 minutes with over 1100lm of emergency brightness. Electric Characteristic Specification/Model Input Power Luminous Flux Emergency Luminous Flux Lumen Efficacy CRI Color Temperature Input Voltage Light Distribution Type Work Current Work Frequency LDS-EMT8-18WBC-50K 18W 2200lm±5% 1100lm±5% 115LM/W 80 5000K 100-277VAC 120° 0.182A@90VAC:0.090A@277VAC 47-63Hz Battery Characteristic Power Factor Charging Time Emergency Time Emergency Power Battery Type PF THD LED Type 0.99@90VAC:0.91@277VAC >10hrs 120mins 5-8W Polymer Lithium-lon Battery (11.1V, 2AH) 0.9 20% SMD2835LED LS-EMT8-A.0 1 of 4 Emergency Tube Light Distribution Diagram LDS-EMT8-18WBC-50K Dimension -120 -90 90 150 300 -60 450 600 750 AVERAGE BEAM ANGLE (50%): 150° Test Number: LDS-EMT8-18WBC-50K Lumens: 2200LM Test Number: 18W Test Number: 5000K UNIT:CD C0/180,110.9 C30/210,110.5 C60/240,109.3 C90/270,109.1 Maximum overall length (mm) A B C D E 4ft 1212mm 1198mm 1138mm 28.5mm 32.5mm Tips: 1. About automatic detection: as long as the test switch (Test) is pressed, or the mains is re-supplied, the internal program will restart the timer. After 12 hours, the first automatic test will be performed, and the emergency state will be activated for 1 minute. After confirming that the emergency function is normal will return to normal state automatically. If the emergency function is abnormal within 1 minute, the program will automatically resume charging for 1 hour and then re-test. When confirmed it's not normal for the second time, the green indicator will start to flash to alarm, confirming that the internal device is abnormal and cannot work normally, stop using it immediately, Ask a professional to repair or replace it. 2. Monthly inspection function: When the product continues to work normally for 30 days, the internal program will automatically start an emergency function test. 3. Special situation: When the product lasts for more than 12 hours and the ON/OFF switch is not turned on, the internal program will determine there is a fault, and the green light will flash an alarm. At this time, Need to turn on the ON/OFF switch first, and then press the TEST test button or mains is re-supplied. then can back to normal use. LS-EMT8-A.0 2 of 4 Emergency Tube Light Function Introduction 1. ON/FF: Black hidden switch to active emergency function. Remark: This switch is default closed before leaving factory, by use a small sharped object into the hole to press it, as long as the noise heard means the swichis turned on. At the same time the tube will start emergency function if haven't install into the fixture. When the tube's indicators (red, green) flashing alternately after installing into the fixture which means the internal switch is not turned on, please repress it. 2. Test: The red button is for testing the emergency function if normal when the tube is working. When pressed, the lamp immediately starts the emergency state and lights up, and returns to normal after release it. Each time this button is pressed, the internal program time is cleared, and the automatic detection time will be restarted. 3. Full: The green indicator "steady on" means "the intemal battery is fully charged" 4. Charge: The red indicator "steady on" means the battery is being charged and will automatically turn of when fully charged. Note: When the red and the green indicator flashing alternately, it means that the ON/OFF switch is not turned on, please press again. When the emergency function is activated the green and red indicators will go out at the same time. Installation Method Installation Guide · Before installation, check if the connected voltage, frequency, etc. are consistent with the product parameters. · Ensure that the input voltage and frequency are within the specified range before installation. · It should be installed by qualified electricians and ensure that the power is completely turned off before installation. · When installing, make sure that the "hidden battery switch button" is in the pressed status, and the traffic lights. · When installing, make sure that the "hidden battery switch button" is in the pressed status, and the traffic lights do not flash alternately · No need for starter and ballast, or please confirm that the above components are disconnected; the lamp connection and installation wiring diagram is divided into TYPE-B and TYPE-C as shown below · After installation, please check carefully and then test it. Install the Wiring Diagram Figure 1. Wiring diagram without a HOT line: DEFAULT MODE : TYPE B LS-EMT8-A.0 3 of 4 Emergency Tube Light Figure 2. Wiring diagram with a HOT line: TYPE C Precaution · After installation, please check carefully and then test it after confirming that it is correct. · The installation accessories need to be installed firmly. · After the installation and wiring of the light is completed, the power is tested again to guard against electric shock. · Please do not open the light and change the electrical structure, Otherwise the damage caused is not covered by the warranty. LS-EMT8-A.0 4 of 4Corel PDF Engine Version 17.4.0.887