Instruction Manual for b d models including: 12-100 Series Structural Fixing Detail for Shutter Openings, 12-100 Series, Structural Fixing Detail for Shutter Openings, Fixing Detail for Shutter Openings, Shutter Openings

PDF preview unavailable. Download the PDF instead.

165026 00-shutter-noggin-details
6,8,10 & 12/100 Series Structural fixing detail for shutter openings

Please follow diagram for correct installation of shutters up to:

6800mm high x 7000mm wide

A1/A2

G

B

CEILING

E

· Fixing (shown shaded) steel.
· Material for wind rated doors MUST comply with the DTC drawings, which can be found on the B&D website.
· Depending on door size and weight, steel will be required. All masonry must be solid bricks or core filled. Steel must be of a suitable thickness. If unsure consult with your engineer or B&D representative.
· If floor rebate is required it must extend at least 100mm more than the opening on each side and back from the fixing face at least 100mm.

OPENING HEIGHT

C

B

A1/A2

OPENING

D

F

FLOOR REBATE

SOLID RETURN

installation
Spring Balanced
Springless Direct Drive
Springless Direct Lift
Chain Drive

height (mm) up to 3000 3001 - 3900 3901 - 5100 5101 - 6500 6501 - 6800 up to 3000 3001 - 3900 3901 - 5100 5101 - 6000 up to 3000 3001 - 3900 3901 - 5100 5101 - 6500 6501 - 6800

width (mm)
up to 7000
5405- 7000 up to 4200 up to 6000 up to 5700 up to 6000
up to 7000
5405- 7000

dimension panel

A

BC

A1* A2

390

440

200 150 150 460

476

492

696

200 N/A 100 710 754

790

696

710

250 N/A 100 760

790

830

D E* F 100 700 700 100 700 700 200 1000 600

G 590 640 660 675 692
1040
744 765 831 885 915

*A1 recommended sideroom based on the opener being installed. A2 recommended sideroom without opener.
*E recommended sideroom length based on the opener being installed

Doc: 165026_00 Released: 02/03/2023 All references are taken from inside looking out.

Roll-A-Shutter Structural fixing detail for shutter openings

2

Please follow diagram for correct installation of shutters up to:

10000mm high x 12000mm wide

A1/A2

G

B

CEILING

E

· Fixing (shown shaded) steel.
· Material for wind rated doors MUST comply with the DTC drawings, which can be found on the B&D website.
· Depending on door size and weight, steel will be required. All masonry must be solid bricks or core filled. Steel must be of a suitable thickness. If unsure consult with your engineer or B&D representative.
· If floor rebate is required it must extend at least 100mm more than the opening on each side and back from the fixing face at least 100mm.

OPENING HEIGHT

C

B

A1/A2

OPENING

D

F

FLOOR REBATE

SOLID RETURN

installation
Spring Balanced
Springless Direct Drive
Springless Direct Lift
Chain Drive

height (mm) up to 2400 2401 - 3000 3001 - 3900 3901 - 5100 5101 - 6500 up to 3000 3001 - 3900 3901 - 5100 5101 - 6500 6501 - 6800 up to 3000 3001 - 4200 4201 - 5400 5401 - 6500 6501 - 7500 7501 - 9000 9501 - 10000

width (mm) 7000 - 10000 7000 - 9000 7000 - 8500 7000 - 8000 7000 - 7500 7000 - 9000 7000 - 8500 7000 - 8500 7000 - 7500 7000
7000 - 12000

dimension panel

A A1* A2

B

C

390

440

200 150 150 460

476

492

700

768

200 N/A 100 820

850

860

720

768

820

250 N/A 100 850

860

890

910

D E* F 100 700 700 100 700 700
200 1000 600

G 590 640 660 676 692
1040
780 852 930 975 990 1010 1040

*A1 recommended sideroom based on the opener being installed. A2 recommended sideroom without opener.
*E recommended sideroom length based on the opener being installed


Adobe PDF Library 17.0 Adobe InDesign 18.2 (Windows)