INSTALLATION AND OPERATION INSTRUCTIONS
4400 SERIES POWER PAKS

MODELS

4400 Series

4404

4404W

4410

4410W

4414

4414W

4414-230

4420W

4420

C

US

IMPORTANT INFORMATION
To register your product, visit our web site at www. perlick.com. Click on Commercial, then Service. You will see the link to Warranty Registration Form. You must complete and submit this form or the installation date will revert back to the ship date.
Permanently mount the enclosed Warning/Safety Instruction label in a visible location near the CO2 regulator.
This manual has been prepared to assist you in the installation of your Century Remote Beer System and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, your dealer can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.

Table of Contents Sizes & Specifications ............................................ 2-3
Air-Cooled Models ................................................. 2 Water-Cooled Models............................................ 3
General Information.......................................... 4 Installation ........................................................ 5 Connecting Power Pak to Trunk Housing.............. 6 Connecting to Trunk Housing ................................ 7 Power Pak Start-Up................................................... 8 LEDS ......................................................................... 9 Preventative Maintenance ......................................... 9 Replacement Parts .................................................. 10 Wiring Diagrams ...................................................... 11
Form No. Z2020 Rev. 04.15.2015

8300 West Good Hope Road · Milwaukee, WI 53223 · Phone 414.353.7060 · Fax 414.353.7069 Toll Free 800.558.5592 · E-Mail perlick@perlick.com · www.perlick.com

4400 SERIES POWER PAKS - AIR COOLED
Operation/Installation Manual

MODEL NOS.

4404

4410

4414

4414-230

4420

DIMENSIONS: EXTERIOR (mm)

Length "A" Width "B"

241/4" (616) 171/4" (438)

241/4" (616) 171/4" (438)

241/4" (616) 171/4" (438)

263/4" (679) 201/4" (519)

263/4" (679) 201/4" (519)

Height "C"

251/2" (648)

251/2" (648)

251/2" (648)

31" (782)

31" (782)

A minimum of six inches of clearance should be allowed around the entire unit for proper performance. Additional clearance should be considered for above the unit and in front of the unit for servicability.

ELECTRICAL

Voltage

120 V

120 V

120 V

208/230 V**

208/230 V**

Frequency

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

Phase

1 Ø

1 Ø

1 Ø

1 Ø

1 Ø

SINGLE PUMP

RLA (Rated Load Amps)

15.1

15.7

17.1

10.5

21.9

MCA (Min. Circuit Ampacity)

17.2

18.0

19.6

12.2

26.4

MOCP (Max. over Current Protection)

25

25

25

15

40.0

DUAL PUMPS (add -2 to model #)

RLA (Rated Load Amps) MCA (Min. Circuit Ampacity)

N/A

21.8

22.7

13.3

24.7

N/A

24.1

25.2

15.0

29.2

MOCP (Max. over Current Protection)

N/A

30.0

35.0

20.0

45.0

TRIPLE PUMPS (add -3 to model #)

RLA (Rated Load Amps) MCA (Min. Circuit Ampacity)

N/A

N/A

N/A

16.1

27.5

N/A

N/A

N/A

17.8

32.0

MOCP (Max. over Current Protection)

N/A

N/A

N/A

20.0

50.0

COMPRESSOR

1/3 HP

1/2 HP

3/4 HP

3/4 HP

1.5 HP

EVAPORATOR RATING @ 20°F (BTUH)

3420

3800

6000

6300

12000

HEAT REJECTION (MAX)

4080

6080

9600

10080

19200

REFRIGERANT

R-134a

R-134a

R-134a

R-134a

R-134a

SHIPPING WEIGHT LBS (kg)

140 (64)

153 (69)

180 (82)

205 (93)

255 (116)

CABINET

Stainless Steel

CIRCULATING PUMP

100 GPH/130 PSIG

RESERVOIR CAPACITY

1.75 gal

1.75 gal

1.75 gal

1.75 gal

1.75 gal

REFRIGERATION

Constant Pressure Expansion Valve, Condensing Unit with Service Valves

REFRIGERANT CHARGE (grams)

14.0 oz/397 g

12.0 oz/340 g

9.5 oz/269 g

11.0 oz/312 g

16.0 oz/453 g

GLYCOL CONCENTRATION

30%

30%

30%

30%

30%

OPTIONAL ACCESSORIES

4430 115V pump kit for 4410 Power Pak (field installed) 4431 115V pump kit for 4414 Power Pak (field installed) 4432 208/230V pump kit for 4414/230V and 4420 Power Paks (field installed) 4435 BLM Receptacle 4408SS Wall Bracket for 4404 & 4410 only C21499BSS Stainless Steel Table Stand

61790 Dual Tier Rack 61791+1 Triple Tier Rack 61792+2 Quad Tier Rack C22296A-20 Cord Kit for 120V single pump Power Paks only (Field installed)

**Requires four wires (2 hot, 1 neutral and 1 ground).

C

US

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
2

4400 SERIES POWER PAKS - WATER COOLED
Operation/Installation Manual

MODEL NOS.

4404W

4410W

4414W

DIMENSIONS: EXTERIOR (mm)

Length "A" Width "B"

241/4" (616) 171/4" (438)

241/4" (616) 171/4" (438)

263/4" (679) 201/4" (519)

Height "C"

251/2" (648)

251/2" (648)

31" (782)

A minimum of six inches of clearance should be allowed around the entire unit for proper performance. Additional clearance should be considered for above the unit and in front of the unit for servicability.

ELECTRICAL

Voltage

120 V

120 V

120 V

Frequency

60 Hz

60 Hz

60 Hz

Phase

1 Ø

1 Ø

1 Ø

SINGLE PUMP

RLA (Rated Load Amps)

15.4

17.1

17.4

MCA (Min. Circuit Ampacity)

17.7

19.9

20.4

MOCP (Max. over Current Protection)

25.0

30.0

30.0

DUAL PUMPS (add -2 to model #)

RLA (Rated Load Amps) MCA (Min. Circuit Ampacity)

21.5

23.2

23.0

23.8

26.0

26.0

MOCP (Max. over Current Protection)

30.0

35.0

35.0

TRIPLE PUMPS (add -3 to model #)

RLA (Rated Load Amps) MCA (Min. Circuit Ampacity)

N/A

N/A

28.6

N/A

N/A

31.6

MOCP (Max. over Current Protection)

N/A

N/A

40.0

COMPRESSOR

1/3 HP

1/2 HP

3/4 HP

EVAPORATOR RATING @ 20°F (BTUH)

3420

4080

6870

HEAT REJECTION (MAX)

2050

2450

4122

REFRIGERANT

R-134a

R-134a

R-134a

SHIPPING WEIGHT LBS (kg)

141 (64)

143 (65)

205 (93)

CABINET

Stainless Steel

CIRCULATING PUMP

100 GPH/130 PSIG

RESERVOIR CAPACITY

1.75 gal

1.75 gal

1.75 gal

REFRIGERATION

Constant Pressure Expansion Valve, Condensing Unit with Service Valves

REFRIGERANT CHARGE (grams)

14.5 oz / 410 g

14.5 oz / 410 g

22.0 oz / 623 g

GLYCOL CONCENTRATION

30%

30%

30%

PLUMBING REQUIREMENTS

INLET & OUTLET

All employ 1/2" O.D. Quick Connect Fittings

FLOW RATE (gpm) @ 75°F

0.5

0.6

0.9

PRESSURE DROP (psig)

0.1

0.2

0.4

MAX SUPPLY PRESSURE

All Models: Incoming Water Pressure not to exceed 150 psig

OPTIONAL ACCESSORIES

4430 115V pump kit for 4410 Power Pak (field installed) 4431 115V pump kit for 4414 Power Pak (field installed) 4435 BLM Receptacle 4408SS Wall Bracket for 4404 & 4410 only 57782 Set of four adjustable legs 54838 Water hammer arrestor (add if incoming water is under 65°F) 61790 Dual tier rack 61791+1 Triple tier rack 61792+2 Quad tier rack C22296A-20 Cord Kit for 120V single pump Power Paks only (Field Installed) C21499BSS Stainless Steel Table Stand

4420W 263/4" (679) 201/4" (519) 31" (782)
208/230 V*** 60 Hz 1 Ø 20.8 25.3 40.0 23.6 28.1 45.0 26.4 30.9 45.0
1-1/2 HP 13,800 6500 R-134a 255 (116)
1.75 gal
22.0 oz / 623 g 30%
1.2 0.5

C

US

WATER INLET WATER OUTLET

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
3

Form No. Z2020 Rev. 04.15.2015

4400 SERIES POWER PAKS - GENERAL INFORMATION
Operation/Installation Manual

Accessories

PRODUCT DESCRIPTION

Power Cord Kit C2296A-20--12/3 Cord, 20A, Nema Plug 5-20P, Dedicated Circuit Models - See above electrical specifications
Power Pak Racks 61790, 61790+1, 61790+2 - All Models
Power Pak Wall Mounting Brackets 4408 - For Models 4404 & 4410 only
Coolant Solution-63299-1 One gallon Perlick Coolant solution, 30% DowFrost HD/70% Distilled Water
Coolant Connector Kit 63335 - All Models
Leg Set - All Models 57782 . . . Set of four, 5 3/4"-71/2" adjustable legs
Pump Kits 4430 - Pump kit, 115V, 6.1 A, 100 gph, 130 psig Models 4410, 4410W 4431 - Pump kit, 115V, 5.6 A, 100 gph, 130 psig Models 4414, 4414W 4432 - Pump kit, 230V, 2.8 A, 100 gph, 130 psig Models 4414-230, 4420

Power Paks have always been an integral part of a Perlick Century Beer System. The 4400 Series Power Pak product line has been expanded to satify longer beer runs. A Power Pak circulates coolant solution (food grade propylene glycol with distilled water) from walk-in cooler to the dispensing station(s) and back, maintaining the desired dispensing temperature at the faucet. The 4400 series Power Pak incorporate a 1/3 hp ball bearing, maintenance free motor with a 100 gallon per hour 150 psig positive displacement pump for optimum performance. The 4400 series Power Pak product line employs a direct expansion form of refrigeration increasing the units' efficency as well as making the units more compact. These units also employ an electronic temperature control with digital readout. This state of the art control controls the performance of the unit as well as giving the user a visual indication of the how the unit is working as well as giving the user a visual indication of the how the unit is working as well as early indication if something may be going wrong through the use of internal alarms.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
4

4400 SERIES POWER PAKS - INSTALLATION
Operation/Installation Manual

INSTALLATION
IMPORTANT SAFETY WARNINGS! · Follow all National and Regional Codes. · Read Installation and Operating Instructions
carefully before attempting to install, operate or maintain the product. · Protect yourself and others by observing all safety information. · Electrical hazards exist and can cause injuries if not serviced by properly trained personnel. · Failure to comply with instructions could result in personal injury and/or property damage! · Retain instructions for future reference. · Never operate the circulating pump without coolant in the reservoir.

· Place the Power Pak and Ensure that it is level to provide proper overflow protection. REMINDER: Allow a minimun of six inches of clearace on the louvered ends of the cabinet for proper airflow. Allow accessibility room on the top of the cabinet for serviceability.
· Remove the top panels (2). · Ensure Power Switches for Condensing Unit and
Pump(s) are in the OFF position. Make the electrical connections per ther illustrations. NOTE: Electrical circuit shold be a dedicated circuit for use only with the Power Pak. The circuit should be sized in accordance with the electrical requirements of each unit as well as in compliance with all National and Local Codes. · Plumb overflow port to a suitable reservior/drain.

NOTE: Air-cooled Power Paks must be installed in areas with adequate ventilation to maintain ambient temperatures of less than 105°F to achieve optimum performance and satisfy warranty requirements.
INSTALLING THE POWER PAK Prior to installing a 4400 Series Power Pak, it is imperative that the method of connecting it to the electrical service has been determined. Ensure that the electrical service to power the Power Pak will handle the load requirements. Perlick has a Power Cord specifically designed for a Power Pak, which has a RLA of 16 amps or less, and a MCA of 20 amps or less. All units with RLA greater than 16 amps and a MCA of greater than 20 amps should have the Power Pak hard-wired to electrical service.
ALL MODELS · Determine the ideal placement of the Power Pak.
Locate the connection point to the truck housing and place the Power Pak as close to this point as possible. NOTE: If the Power Pak is to be located on top of the walk-in cooler, it is imperative that proper ventilation is provided to prevent system failure due to overheating. Inadequate ventilation will void warranty.

WATER-COOLED MODELS · In addition to the above installation instruction: · Care should be exercised in locating the Power
Pak so that the unit will never be exposed to temperatures below freezing. · If the Power Pak is installing more than 5 feet higher than the remote outlet drain point (i.e., location of the floor drain) of the condenser, a vacuum breaker or open vent line should be provided to prevent the discharge line from creating a partial vacuum condition in the condenser water system. · If a water-circulating pump is used it should be placed on the water supply side of the condenser, so water is being pushed through the condenser. · A potable water supply is required as well as a drain or reclamation system. Make water supply connection to fitting labeled as the water inlet. Make outlet connection to fitting labeled as the water outlet connection. Both the inlet and outlet fittings supplied with the Power Pak are 1/2" Quick Connect fittings.

4400 SERIES POWER PAKS - INSTALLATION
Operation/Installation Manual

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
5

Form No. Z2020 Rev. 04.15.2015

4400 SERIES POWER PAKS - GENERAL INFORMATION
Operation/Installation Manual

CONNECTING POWER PAK TO TRUNK HOUSING 400 Series Power Paks require rigid fittings with a minimum pressure rating of 150 psig. Use Coolant Connector Kit #63335 to connect Power Pak to Trunk Housing. · Inspect pump outlet port for debris. Insert barbed
fitting #63307 into pummp outlet port. · Inspect Glycol Return Manifold inlet for debris.
Insert barbed fitting #63307 into return manifold inlet port. · Cut supplied coolant tubing, #54588, to required length to reach from Power Pak to Trunk Housing connection point. · Cut tubular insulation sleeve, #C12700, in half and install over previously cut coolant tubing. · Take Oetiker clamps, #54871-210, and install over coolant tubing ends. · Push coolant lines, one each over pump outlet barbed fitting #63307 and return manifold barbed fitting #63307. · Position Oetikers over barbed fitting and clamp securely. · Slide tubular insulation sleeves tightly against connection points. Use insulation tape as necessary to ensure an air tight seal to prevent excessive heat gain or condensation problems. · Drill a 3-1/2" diameter hole in walk-in cooler to accommodate coolant lines. · Install insulation donuts over hole (both inside and outside of cooler walls. · Slide large insulation sleeve, #57478, over remaining coolant tubing exposed to warm air conditions including inside walk-in cooler from Power Pak to Trunk Housing connection point. Seal and tape all seams to prevent excessive heat gain or condensation problems. · Slide coolant lines through 3-1/2" donut hole previosly cut in walk-in cooler wall.

· Position Trunk Housing coolant lines and Coolant Connector kit lines in horizontal position, to alleviate condensation runoff into Trunk Housing.
· Cut Trunk Housing coolant lines with tubing cutter to ensure clean burr free ends.
· Take Oetikers clamps #54871-210, and install over coolant connector kit tubing ends.
· Slide coolant connector kit tubing over the trunk housing coolant lines and secure using the Oetikers.
· Complete the insulation process by ensuring that all coolant lines are well insulated including all seams to prevent excessive condensation and heat gain.
· Seal donut hole to ensure an air tight seal to prevent walk-in cooler problems as well as condensation.
CONNECTING TRUNK HOUSING COOLANT LINES TO DISPENSING HEAD · Position the trunk housing so that beverage lines
can be connected with a minimum cutting. · Split trunk housing approximately 12 inches from
the end to allow working room for the connections. · Cut and deburr copper coolant lines coming from
trunk housing and dispensing head. Stagger the lengths. · Connect trunk housing coolant lines to dispensing head coolant lines using clamps, hose and 3/8" x 1/2" union, included in Head connecting kit, #63486. Ensure that coolant lines are fully clample to guarantee a leak free connection.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
6

4400 SERIES POWER PAKS - INSTALLATION
Operation/Installation Manual

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
7

Form No. Z2020 Rev. 04.15.2015

4400 SERIES POWER PAKS - START-UP
Operation/Installation Manual

SYSTEM START-UP Use only Perlick Approved Coolant Solution, #632991, all other solutions and mixtures will void the Perlick warranty. The Coolant Solution has been pre-mixed for optimum performance and wear protection. The Power Pak resevoir holds approximately 1.75 gallons of solution. It takes approximately 1 gallon of Coolant Solution to fill every 60 feet of Perlick Trunk Housing. · Never operate the circulating pumps without coolant
in the resevoir. · Fill Power Pak resevoir with Perlick Coolant Solution. · Turn condensing unit switch and pump switch to the
ON position. Coolant solution level will begin to drop in resevoir. · Continue adding Perlick Coolant Solution until no air bubbles are apparent from the Coolant return line. NOTE: Never allow for the Coolant level in the resevoir to drop below the heat exchanger tube inlet. Allowing the level to drop below the inlet will allow air into the lines. · Fill Power Pak reservoir until both the return line fitting port and the overflow tube port are submersed under Coolant Solution. Watch return line fitting port for additional Coolant Solution may need to be added. · Thoroughly check all field connection points for leaks. · Monitor Power Pak Temperature read-out to ensure Power Pak is working properly. Dependent on length of trunk housing run(s) and surrounding ambient conditions, these factors will determine how long it takes for the Power Pak to cut-out on the temperature control.

DIGITAL TEMPERATURE CONTROLLER The 4400 Series Power Pak comes equipped with a Factory Programmed Electronic Thermostat with display. The Thermostat has numerous factory settings, which should never be adjusted or tampered with to ensure proper operation of the Power Pak. The Thermostat has been factory programmed to cut-out at 30°F with a hysteresis/differential of 4°F.
Front Panel Commands­Normal Operation SET: To display target set point. DEFROST: To start a manual defrost. (This feature is available, however, the parameters for actuation are programmed, such that, no defrost is available).
Front Panel Commands­Programming Mode SET: Selects a parameter or confirms an operation. UP ARROW: Browses the parameter codes or increases the displayed value. DOWN ARROW: Browses the parameter codes or decreases the displayed value.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
8

POWER PAKS - LEDS & PREVENTATIVE MAINTENANCE
Operation/Installation Manual

Meaning of LEDS

LED SNOWFLAKE

MODE ON

FUNCTION Compressor Enabled

SNOWFLAKE Phase (flashing with DEFROST)

FLASHING

DEFROST

FLASHING

Phase (flashing

with SNOWFLAKE)

Programing
Anti-short cycle delay enabled Programming
Drip time in progress

DISPLAY MESSAGE MEANINGS

MESSAGE POF

MEANING Keyboard is locked out. No parameters can be adjusted without unlocking the keyboard.

ALARM EE
P1

MEANING ACTION

Data or

Consult Factory

memory failure

Room probe Numerous - see

failure

note 1

NOTE 1: Faulty probe, loose connection, broket wire. (Power Pak will continue to operate with a faulty probe. The controller has been factory programmed to continue operation with the compressor cycling on and off in 5 minute intervals.

How to see the SETPOINT · Press and immediately release the SET key: the
display will show the Set point value. · Press and immediately release the SET key or wait
for 5 seconds to display the probe value again.
How to change the SETPOINT · Press and hold the SET key for more than 2
seconds to change the Set point value. · The value of the set point will be displayed and the
SNOWFLAKE LED starts blinking. · To change the Set value, press the UP or DOWN
ARROWS, dependent on the new set point value. · To memorize the new set point value, press the SET
key again or wait 15 seconds.
WARNING: IF MESSAGE OR INFORMATION SHOWN ON READOUT IS UNFAMILIAR, ALLOW CONTROL TO SIT FOR A MINIMUN OF 15 SECONDS AND CONTROLLER SHOULD RETURN TO DISPLAY PROBE TEMPERATURE.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
9

Form No. Z2020 Rev. 04.15.2015

4400 SERIES POWER PAKS - REPLACEMENT PARTS
Operation/Installation Manual

Replacement Parts
COMPONENT/MODEL Condensing Unit
Compressor

4404 572FG5108AA
(C22652)
262FG92UB.2

4410 559HG5110HA
(C22667)
269HG9290AF

4414
C22634 AJ250AT-188-J7

Cond Fan Motor Fan Blade Start Components Water Regulator Pump Motor Heat Exchanger Gasket, Heat Exchanger Grille Front Panel Contactor Relay, Pump

1450076 2455003 US-PBNE6210Z1
N/A 63292 63303A 61758A 64197-1SS 64407-1SS
N/A N/A

1450095 2455003 US-PBNEK6214Z1
N/A 63292 63300A 61758A 64197-1SS 64407-1SS
N/A N/A

COMPONENT/MODEL Condensing Unit
Compressor
Cond Fan Motor Fan Blade Start Components Water Regulator Pump Motor Heat Exchanger Gasket, Heat Exchanger Grille Front Panel Contactor Relay, Pump

4404W C22640 ARE51C4ECAA-901
N/A N/A
510-0049-00 63292 63300A 61758A
64197-1SS 64407-1SS
N/A N/A

4410W C22641 RRT62C1EIAA-901
N/A N/A
510-0049-00 63292 63300A 61758A
64197-1SS 64407-1SS
N/A N/A

TFM351 51541-1
N/A 63293 63301A 61758A 64197-1SS 64407-1SS
N/A N/A
4414W C22642 RRT10K1EPKA-959
N/A N/A
510-0049-00 63293 63301A 61758A
64197-1SS 64407-1SS
N/A N/A

4414-230
C22645 RRT10K1E-
PFV-959 950-0344-00
N/A 63293 63301A 61758A 64285-1SS 64285-1SS 63359 63358
4420W C22666 CS18K6EPKV-970
N/A N/A
510-0049-00 63293 63302A 61758A
64285-1SS 64286-1SS
63359 63358

Common Components

COMPONENT/MODEL

ALL MODELS

Expansion Valve Pump V-Clamp Pump Insulation Zip Tie, Pump Insul Temp Control Kit

63826 63291-1 63291-2 64425 57551 67177

COMPONENT/MODEL
Controller, Digital Compression Fitting Switch Drier Coolant Solution

ALL MODELS
67139 63296-3 63303 63297 63299-1

4420
C22668 ZS19KAEPFV-818 950-0265-00 083-0033-01
N/A 63293 63301A 61758A 64286-1SS 64286-1SS 63359 63358

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
10

4400 SERIES POWER PAKS - WIRING DIAGRAMS
Operation/Installation Manual

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
11

Form No. Z2020 Rev. 04.15.2015