Owner's Manual for ECOWATER SYSTEMS models including: ETF2300SM10, ETF2302SM10C, ETF2300SM10 Eco ProTech Anti Scale System, ETF2300SM10, Eco ProTech Anti Scale System, Anti Scale System, Scale System, System
ETF2302SM10CC – EcoWater Systems
File Info : application/pdf, 9 Pages, 944.06KB
DocumentDocumentOWNER'S MANUAL How to install, operate and maintain your EcoProTechT Anti-Scale System Model ETF2300SM10 EcoProTechT Plus 2-Tank Anti-Scale System with Carbon Filtration Model ETF2302SM10C Point-of-entry systems tested and certified by NSF International for NSF/ANSI/CAN Standard 372, and are not certified for material safety, contaminant reductions, or structural integrity by NSF International. Designed, Engineered & Assembled in the U.S.A. EcoWater Systems LLC P.O. Box 64420, St. Paul, MN 55164-0420 www.ecowater.com 7358959 (Rev. J 1/30/24) ECOWATER SYSTEMS Table of Contents, Specifications & Dimensions TABLE OF CONTENTS Page Specifications . . . . . . . . . . . . . . . . . . . . . . . . 2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Before Starting Installation . . . . . . . . . . . . . . 3 Typical Installation Illustrations . . . . . . . . . 4-5 Installation Instructions . . . . . . . . . . . . . . . . . 6 Adding PPT Anti-Scale Media . . . . . . . . . . . 7 Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . 8 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SPECIFICATIONS Model ETF2300SM10 ETF2302SM10C Nominal Mineral Tank 10" dia. x 35" tall 10" dia. x 35" tall Size (1) (2) Amount of PTT Anti-Scale Media Amount of Activated Carbon Amount of HDPE Pellets 4.3 lbs. (1.95 kg) 3 lbs. (1.36 kg) 4.3 lbs. (1.95 kg) 14 lbs. (6.35 kg) 6 lbs [3 lbs./ tank] (2.72 kg) Service Flow Rate 10 gpm (37.8 L/min.) Maximum Flow Rate 15 gpm (56.8 L/min.) Supply Water Pressure Limits (min./max.) 20 - 125 psi (137.9 - 861.8 kPa) Water Temperature Limits (min./max.) 40 - 120 °F (4 - 49 °C) Model ETF2300SM10 1144--11//44"" OOUUTT 33"" IINN TTOOPP VVIIEEWW 1133--55//88"" DIMENSIONS 1144--11//44"" OOUUTT 33"" IINN Model ETF2302SM10C 1133--55//88"" OOUUTT 33"" IINN TTOOPP VVIIEEWW 1133--55//88"" ININ--OOUUTT ININ--OOUUTT 39-B1/2" 4A5" 39-B1/2" Carbon Tank Anti-Scale Media Tank 4A5" SSIIDDEE VVIIEEWW FFRROONNTT VVIIEEWW SSIIDDEE VVIIEEWW 2 FFRROONNTT VVIIEEWW FIG. 1 ECOWATER SYSTEMS HOW THE ANTI-SCALE SYSTEM WORKS Hard water forms "scale" deposits in plumbing. These deposits are composed of calcium carbonate (CaCO3) and magnesium carbonate (MgCO3). As scale builds up over time, it can clog plumbing and coat the heating element in your water heater, significantly reducing its efficiency and life. Unlike a traditional water softener which uses ion exchange media to remove calcium and magnesium ions from the water, the EcoProTechT system converts them into a crystalline form that is less prone to forming scale. This system does not require water for backwashing and does not discharge water to the drain. Since the EcoProTechT system does not require the addition of salt or chemicals, it is practically maintenance free. The system may benefit from having PTT anti-scale media added every few years by your EcoWater dealer, based on your water use and water conditions. INSPECT SHIPMENT The parts required to install the Anti-Scale System are included with the unit. Thoroughly check the system for possible shipping damage and parts loss. Remove and discard (or recycle) all packing materials. SAFETY GUIDES = Follow the installation instructions carefully. Failure to install the system properly voids the warranty. = Before you begin installation, read this entire manual. Then obtain all the materials and tools you will need to make the installation. = Check local plumbing codes. The installation must conform to them. = Use only lead-free solder and flux for all sweat-solder connections as required by state and federal codes. = Use care when handling the system. Do not turn upside down, drop, or set on sharp protrusions. = Recommended maximum allowable inlet water pressure is 125 psi. Use a pressure reducing valve if necessary. = This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Before Starting Installation WHERE TO INSTALL THE SYSTEM = Place the system as close as possible to the pressure tank (well system) or water meter (city water). = Connect the system to the main water supply pipe upstream of the water heater. Do not run hot water through the system. The temperature of water passing through the system must not be above 120°F. Damage caused by hot water is not covered by the warranty. = Do not install the system where freezing temperatures could occur. Damage caused by freezing is not covered by the warranty. = Keep outside faucets on untreated water to conserve media capacity. = Put the system in a place water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage. = If installing in an outside location, you must take the steps necessary to assure the system is as well protected from the elements, contamination, vandalism, etc., as when installed indoors. = Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to nonmetallic parts. TOOLS, PIPE & FITTINGS, OTHER MATERIALS YOU WILL NEED = Plastic inlet and outlet fittings included with the system allow water flow equivalent to 1 inch nominal pipe. To maintain full valve flow, 1" pipes to and from the system fittings are recommended. Do not reduce the pipes to less than 3/4" size. = Use copper, brass or PEX plastic pipe and fittings. = ALWAYS install the included bypass valve, or 3 shut-off valves. Bypass valves let you turn off water to the system for repairs if needed, but still have water available to the house pipes. PLAN HOW YOU WILL INSTALL THE SYSTEM You must first decide how to run in and out pipes to the system. Look at the house main water pipe at the point where you will connect the system. Is the pipe soldered copper, glued plastic, or threaded brass/galvanized? What is the pipe size? Now look at the typical installation illustrations on pages 4 & 5. Use them as a guide when planning your particular installation. Be sure to direct incoming, untreated water to the "UPFLOW INLET" port. For 2-tank Model ETF2302SM10C, you must install the carbon tank UPSTREAM of the anti-scale media tank, as shown on page 5. 3 ECOWATER SYSTEMS Typical Installation Illustrations Model ETF2300SM10 INSTALLATION USING INCLUDED BYPASS VALVE Untreated Water IN Untreated Water to Outside Faucets MAIN WATER PIPE 1" Female NPT Pipe Adapter (2) not included Treated Water OUT Model ETF2300SM10 INSTALLATION USING 3-VALVE BYPASS MAIN WATER PIPE Plumbing Adapter (2)* UPFLOW INLET Bypass Valve* For treated water (service): -Open the inlet and outlet valves For untreated (bypass): -Close the inlet and outlet valves -Open the bypass valve * Included with system - Pipe and fittings supplied by installer. UPFLOW INLET BYPASS Valve INLET Valve Plumbing Adapter (2)* OUTLET Valve NOTE: System shown without top cover, faceplate or support for clarity. FIG. 2 1" Female NPT Pipe Adapter (2) not included FIG. 3 BYPASS VALVE OPERATION SERVICE BYPASS (water flows through Anti-Scale System, (water flows to house plumbing and then to house plumbing) without going through Anti-Scale System) FIG. 4 4 ECOWATER SYSTEMS Typical Installation Illustrations 2-Tank Model ETF2302SM10C INSTALLATION USING INCLUDED BYPASS VALVES Untreated Water IN MAIN WATER PIPE Untreated Water to Outside Faucets NOTE: System shown without top covers, faceplates or supports for clarity. 1" Female NPT Pipe Adapter (4) not included Plumbing Adapter (4)* UPFLOW INLET Treated Water OUT CARBON TANK NOTE: Install the carbon tank UPSTREAM of the anti-scale media tank. Bypass Valve (2)* ANTI-SCALE MEDIA TANK * Included with system - Pipe and fittings supplied by installer. FIG. 5 Untreated Water IN 2-Tank Model ETF2302SM10C INSTALLATION USING 3-VALVE BYPASS MAIN WATER PIPE Untreated Water to Outside Faucets NOTE: System shown without top covers, faceplates or supports for clarity. INLET VALVE Plumbing Adapter (4)* UPFLOW INLET BYPASS VALVE Treated Water OUT OUTLET VALVE For treated water (service): -Open the inlet and outlet valves For untreated (bypass): -Close the inlet and outlet valves -Open the bypass valve CARBON TANK NOTE: Install the carbon tank UPSTREAM of the anti-scale media tank. 1" Female NPT Pipe Adapter (4) not included ANTI-SCALE MEDIA TANK * Included with system - Pipe and fittings supplied by installer. FIG. 6 5 ECOWATER SYSTEMS Installation Instructions 1. TURN OFF WATER SUPPLY a. Close the main water supply valve near the well pump or water meter. b. Shut off the electric or fuel supply to the water heater. c. Open high and low faucets to drain all water from the house pipes. 2. INSTALL BYPASS VALVE AND/OR PLUMBING ADAPTERS: a. If installing a single bypass valve, thread the bypass valve, with lubricated o-ring seals in place, onto the head inlet and outlet ports (See Figs. 2 & 5). Tighten the collars by hand for a leak-tight seal. - OR - b. If installing a 3-valve bypass system, thread the included plumbing adapters, with lubricated o-ring seals in place, onto the head inlet and outlet ports (See Figs. 3 & 6) Tighten the collars by hand for a leak-tight seal. 3. COMPLETE PLUMBING TO AND FROM THE SYSTEM Using the "Typical Installation Illustrations" on pages 4 and 5 as a guide, observe all of the following cautions while you connect inlet and outlet plumbing: = For 2-tank Model ETF2302SM10C, you must install the carbon tank UPSTREAM of the antiscale media tank (See Page 5). = Be sure incoming, untreated water is directed to the UPFLOW INLET port. It may be necessary to plumb a crossover if the water pipe's flow is from right to left. = Be sure to install bypass valve(s). = If making a soldered copper installation, do all sweat soldering before connecting pipes to the included plastic adapters. Torch heat will damage plastic parts. = Use pipe joint compound on all external pipe threads. = When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread. = Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the head adapters. 4. COLD WATER PIPE GROUNDING The house cold water pipe (metal only) is often used as a ground for the house electrical system. The 3valve bypass type of installation, shown in Figures 3 and 6, will maintain ground continuity. If you use the plastic bypass, continuity is broken. To restore the ground, do the following: Ground Wire Clamp (2) FIG. 7 a. Install a #4 copper wire across the removed section of main water pipe, securely clamping at both ends (See Figure 7). Parts not included. 5. FLUSH PIPES AND TEST FOR LEAKS CAUTION: To avoid water or air pressure damage to system inner parts, be sure to do the following steps exactly as listed: a. Fully open two treated water faucets, one cold and one hot, nearby the system. b. Place bypass valve(s) into BYPASS position. On a single valve, turn both handles perpendicular to water flow (See Fig. 4). On a 3 valve system, close the inlet and outlet valves, and open the bypass valve (See Figs. 3 & 6). c. Fully open the house main water pipe shutoff valve. Observe a steady flow from both opened faucets. d. Close both faucets. e. Check your plumbing work for leaks and, if any are found, fix right away. Be sure to observe previous caution notes. f. Turn on the gas or electric supply to the water heater. Light the pilot, if applicable. 6. START UP PROCEDURE a. Place bypass valve(s) into SERVICE position, EXACTLY as follows: = Single Bypass Valve: Turn the outlet (marked downflow inlet on head) handle parallel to water flow. SLOWLY, turn the upflow inlet handle parallel to water flow, pausing several times to allow the system to pressurize slowly. = 3 Valve Bypass: Fully close the bypass valve and open the outlet valve. SLOWLY, open the inlet valve, pausing several times to allow the system to pressurize slowly. b. Check all connections for leaks. c. Fully open a cold water faucet, downstream from the system, and allow 50 gallons of water to pass through the system. This should take at least 20 minutes. Close the faucet. 6 ECOWATER SYSTEMS Adding PPT Anti-Scale Media PROCEDURE FOR ADDING PPT ANTISCALE MEDIA 1. Bypass the system by turning both bypass handles perpendicular to the flow of water (See Fig. 8). 2. Slowly loosen the installation collars between the bypass valve and in/out head (See Fig. 9), allowing pressure to escape from system. 3. When both installation collars between bypass and in/out head are completely loosened from the in/out head, pull the system away from the bypass valve. 4. Holding the tank neck adapter with a strap wrench, unscrew the in/out head from the tank neck adapter (See Fig. 10). Once the in/out head is completely unscrewed, check to see whether the riser pipe (See Fig. 10) is still inserted in the in/out head. Remove it by lifting the in/out head enough to grasp the riser pipe and pull it free from the head. 5. Using a hose or tube that is 3/4" O.D. or less, siphon the water from the mineral tank through the riser pipe. This will prevent the top-bedding HDPE from floating out of the tank as the water rises when adding media. 6. Remove clips and clamps (See Fig. 11), and lift tank neck adaptor and top distributor from the tank neck. Be careful not to lose the o-rings. 7. Plug, cap or tape the open top of the riser pipe (See Fig. 11) to prevent media from entering the riser pipe. IMPORTANT: Media entering the riser pipe will restrict fow and increase system pressure drop significantly. 8. Use a funnel that either fits around the riser pipe or alongside of it and fits inside of the tank neck. 9. Add PPT anti-scale media to the tank. Systems are shipped from the factory with 4.3 lbs. of media. Replacement media is supplied in 1.5 lb. containers (P/N 7353755). 10. Uncover the riser pipe and reassemble the system in reverse order, making sure that all o-rings are in place. NOTE: The riser pipe (See Fig. 10) may have been pulled up from the bottom of the mineral tank. If this has happened, the in/out head may not engage the threads of the neck adapter. To correct this, apply air or water pressure to the riser pipe. This will move the media at the bottom of the tank, allowing the riser pipe to be lowered to the bottom of the mineral tank. Turn handles to bypass Bypass Valve Unscrew collars to remove In/Out Head Unscrew In/Out Head to remove Riser Pipe Tank Neck Adapter Disengage Clips & Clamps Lift out Top Distributor with O-Ring Riser Pipe 7 FIG. 8 FIG. 9 FIG. 10 Tank Neck Adapter Add Media through Tank Neck FIG. 11 ECOWATER SYSTEMS Repair Parts SYSTEM EXPLODED VIEW 1 4 3 2 7 8 6 19 20 5 15 16 9 11 10 17 12 13 14 SYSTEM PARTS LIST Key No. Part No. Description 1 7358802 Top Cover 2 7351753 Head, In/Out 3 7346805 Bypass Valve Assembly, includes o-rings (See Key No. 5) 4 7346790 Adapter, Plumbing, 1" NPT, pack of 2, includes o-rings (See Key No. 5) 7311127 O-Ring, 1-1/16" x 1-5/16", single 5 7336410 O-Ring, 1-1/16" x 1-5/16", pack of 20 6 7342788 Adapter, Tank Neck 7331177 Tank Neck Clamp Kit (includes 2 ea. of Key Nos. 7 & 8) 7 á Clamp Section 8 á Retainer, Clamp 7112963 Distributor O-Ring Kit (includes Key Nos. 9 & 10) 9 á O-Ring, 2-7/8" x 3-1/4" 10 á O-Ring, 2-3/4" x 3" 11 7077870 Top Distributor 12 7105047 Repl. Bottom Distributor 13 7113066 Repl. Mineral Tank, 10" x 35" 7353755 PTT Anti-Scale Media, 1.5 lbs. (systems supplied with 4.3 lbs.) Activated Carbon, 1 cu. ft. (27.5 lbs.) 14 7336834 (14 lbs. used in ETF2302SM10C, not used in ETF2300SM10) HDPE Pellets, 3 lbs. 7351761 (3 lbs. used in ETF2300SM10 & 6 lbs. used in ETF2302SM10C) 15 7353373 Faceplate (order decal below) ¢ 7360257 Decal, Faceplate 16 7353381 Support, Faceplate 7353357 Rim, ETF2300SM10 17 7357539 Rim, ETF2302SM10C 18 7353226 Shroud 19 7352822 Adapter, Plumbing, 1-1/4" NPT, pack of 2, includes o-rings Ù 20 7352830 Adapter, Plumbing, 1-1/4" & 1-1/2" PVC Solvent, pack of 2, incl. o-rings Ù ¢ Not illustrated. Ù Optional parts, not included with system. 18 To order parts, call your local EcoWater dealer or go to www.ecowater.com to locate a dealer in your area. 8 ECOWATER SYSTEMS Warranty LIMITED WARRANTY EcoWater Systems LLC Advantage Warranty Series ETF2300SM10 / ETF2302SM10C Anti-Scale Water Treatment System Congratulations! You have just purchased the highest quality water conditioning product on the market. To whom is this warranty extended? EcoWater Systems LLC warrants its products to the original purchaser, when the product is purchased from an authorized dealer, and guarantees that the products will be free from defects in materials and workmanship from the date that the product is delivered. How does my warranty work? If, during the respective warranty period, a part proves, after inspection by EcoWater, to be defective, EcoWater will, at its sole option repair or replace that part at no charge, other than normal shipping, installation or service charges. What is covered by the warranty? EcoWater Systems LLC guarantees that, for the LIFETIME of the original purchaser, when the product is purchased from an authorized dealer, the MINERAL TANK will not rust, corrode, leak, burst, or in any other manner fail to perform in accordance with its written specifications, and that, for a period of FIVE (5) YEARS from the date the product is delvered, the IN/OUT HEAD will be free of defects in materials and workmanship and will perform in accordance with its written specifications, and that, for a period of FIVE (5) YEARS from the date the product is delvered, the ACTIVATED CARBON will be free of defects in materials and workmanship and will reduce chlorine taste and odor from a municipal water supply, in accordance with its written specifications, and that, for a period of ONE (1) YEAR from the date the product is delvered, the PTT ANTI-SCALE MEDIA will be free of defects in materials and workmanship, and that, for a period of ONE (1) YEAR from the date the product is delvered, ALL OTHER PARTS will be free of defects in materials and workmanship and will perform in accordance with its written specifications. How do I obtain warranty service? Should you need service, your local, independent EcoWater Dealer is only a phone call away. PHONE: __________________________________________________ To obtain warranty service, notice must be given, within thirty (30) days of the discovery of the defect, to your local EcoWater Systems dealer. If I need a part replaced after the factory warranty expires, is the replacement part warranted? Yes, EcoWater Systems LLC warrants FACTORY REPAIRS as well as all REPLACEMENT PARTS for a period of 90 DAYS. This warranty does not include normal shipping, installation or service charges. General Provisions The above warranties are effective provided the water treatment system is operated at water pressures not exceeding 125 psi (8.8 kg/cm2), and at water temperatures not exceeding 120°F (49°C); provided further that the water treatment system is not subject to abuse, misuse, alteration, neglect, freezing, accident or negligence; and provided further that the water treatment system is not damaged as the result of any force of nature such as, but not limited to, flood, hurricane, tornado or earthquake. The limited warranty does not cover damage due to: (a) transportation, (b) storage, (c) improper use, (d) failure to follow the product instructions or to perform any preventive maintenance, (e) modifications, (f) unauthorized repair, (g) normal wear and tear, or (h) external causes such as accidents, abuse, or other actions or events beyond Warrantor's reasonable control. Use of aftermarket, used, or non-manufacturer provided parts will void all warranties. Warranty does not cover failures due to improper product installation. Warrantor is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materials shortages, or other circumstances beyond its control. THERE ARE NO WARRANTIES ON THE WATER TREATMENT SYSTEM BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE EXTENT THEY MIGHT EXTEND BEYOND THE ABOVE PERIODS. THE SOLE OBLIGATION OF WARRANTOR UNDER THESE WARRANTIES IS TO REPLACE OR REPAIR THE COMPONENT OR PART WHICH PROVES TO BE DEFECTIVE WITHIN THE SPECIFIED TIME PERIOD, AND WARRANTOR IS NOT LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. NO DEALER, AGENT, REPRESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND OR EXPAND THE WARRANTIES EXPRESSLY DESCRIBED ABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. This warranty applies to consumer-owned installations only. 9