This document provides instructions for installing a water purge pump onto the MasterCool MCP44 window evaporative cooler.

CAUTION: Ensure unit is turned fully off and unplugged from electrical outlet. Turn off and disconnect water source to cooler unit before proceeding.

Installation Steps

  1. Remove the back of the cooler by extracting 2 screws from the top and 2 screws from the bottom.
  2. Disconnect the water supply tube from the water distribution tray.
  3. Remove the existing hose assembly and replace it with the long piece of tubing from the kit.
    (Remove and discard existing water hose. Replace with long hose from kit.)
  4. Attach the bracket to the pump with two screws (included) and place the strainer basket under the pump before installing the purge pump assembly to the cooler body in the space provided.
    (Place strainer screen under pump, then secure pump assembly to cooler body.)
  5. Attach one end of the purge hose (short hose) to the purge pump and the other end to the overflow fitting. Ensure the overflow fitting is securely tightened to prevent leaks during operation.
  6. Remove the receptacle cover on the back of the fan housing by extracting two screws. Locate the receptacle inside the access panel using needle nose pliers or other means to extract it. Insert the purge pump plug into the receptacle marked with a "P" sticker.
    (Remove two screws holding cover. Locate receptacle inside housing (marked with a "P"), and plug purge pump cord into it.)

    NOTE: When accessing the receptacle for the purge pump, you may extract the main pump cord to make locating the purge pump receptacle easier. Do not unplug the main pump connection. Ensure the purge pump plug is only inserted into the receptacle marked "P".

  7. Push the plug(s) and all excess cord(s) back into the housing and replace the receptacle cover with two (2) screws.
  8. Replace the cooler back, ensuring the water supply hose is reconnected to the water distribution tray. Secure the cooler back with four screws.
  9. Reconnect and turn on the external water supply.
  10. Plug the unit into the electrical outlet. The cooler is ready for operation.

NOTE: The purge pump will expel water in the base of the cooler every 6 hours for approximately 5 minutes. Refer to the MCP44 cooler installation manual for information regarding the proper handling of the expelled water.

P/N 72469
February 2013

Models: MCP44, Window Evaporative Cooler

File Info : application/pdf, 4 Pages, 799.25KB

PDF preview unavailable. Download the PDF instead.

1080916 Man1 Acrobat Distiller 10.1.4 (Windows)

Related Documents

Preview Mastercool MCP12 Window Evaporative Cooler Owner's Manual
Comprehensive owner's manual for the Mastercool MCP12 Window Evaporative Cooler, detailing safety instructions, installation procedures, operating guidelines, maintenance, and troubleshooting tips.
Preview MasterCool CP90 Portable Evaporative Cooler - Features and Specifications
Discover the MasterCool CP90, a portable evaporative cooler designed for efficient spot-cooling in various spaces. Learn about its features, including 3 fan speeds, a programmable timer, remote control, and 1-year limited warranty.
Preview MasterCool MCP12 Window Mount Evaporative Cooler - Cool Up to 1000 sq ft
Discover the MasterCool MCP12, an energy-efficient window mount evaporative cooler. This powerful unit cools spaces up to 1000 sq ft, uses 75% less energy than AC, and features digital controls with a remote. Learn about its features, specifications, and accessories.
Preview Mobile MasterCool Patio Cooler: Quick, Affordable, Stylish Cooling
Discover the Mobile MasterCool Patio Cooler, offering quick, affordable, and stylish cooling solutions for your patio. Learn about its features, specifications, and the benefits of evaporative cooling.
Preview Mastercool ADA71 Owner's Manual and Specifications
Owner's manual and specifications for the Mastercool ADA71 evaporative cooler, including features, dimensions, and electrical data. Find genuine replacement parts for your Mastercool ADA71.
Preview MasterCool AS2C51 Evaporative Cooler Owner's Manual & Specifications
Official owner's manual and detailed specifications for the MasterCool AS2C51 evaporative cooler, including features, cabinet dimensions, electrical data, and model information from Champion Cooler.
Preview Mastercool Commander R/R/R Machines Oil Change Procedure
A guide detailing the oil change procedure for Mastercool Commander R/R/R machines, including steps for draining, filling, and resetting the vacuum pump timer.
Preview Mastercool MC VAC+ Safety Data Sheet
Safety Data Sheet for Mastercool MC VAC+ vacuum pump oil, detailing its properties, hazards, handling, and disposal.