Instruction Manual for HELLA models including: Aluminium Duct with Screen VA Or with Plaster Base VAP, Aluminium, Duct with Screen VA Or with Plaster Base VAP, with Plaster Base VAP, Base VAP

bloXedia

Download | HELLA

Model aluminium duct with screen ...

These instructions must be read prior to installation and use! Model aluminium duct with screen – VA or with plaster base –


File Info : application/pdf, 15 Pages, 1.91MB

PDF preview unavailable. Download the PDF instead.

en-h-ma-va-vap ; filename*=utf-8''EN-H-MA-VA-VAP
Installation Instructions
These instructions must be read prior to installation and use!
Model aluminium duct with screen ­ VA or with plaster base ­ VAP

Installation Instructions
Table of Contents
Preliminary remarks HELLA Model aluminium duct with screen ­ VA or with plaster base ­ VAP ...................................................................................................................................... 3 Before installation ................................................................................................................. 4 Overview: Tools for the installation.......................................................................................5 Overview: Model aluminium duct with screen ­ VA or with plaster base ­ VAP ................... 6 Type overview ...................................................................................................................... 7 Installation in general ........................................................................................................... 9 Installation of the guide rail insert ....................................................................................... 10 Mounting the installation lug ............................................................................................... 11 Installation insect screen rail for integrated moscita insect roller screen ............................ 12 Commissioning/functional check ........................................................................................ 13 Removal ............................................................................................................................. 14

Installation Instructions

Preliminary remarks HELLA Model aluminium duct with screen ­ VA or with plaster base ­ VAP
With this HELLA product you have opted for a high-quality product with a most up-to-date technology that can nevertheless be easily installed and operated. In these instructions we describe the basic installation, commissioning and use.
For authorized specialist staff
For the consumer (user)

Please refer to the enclosed installation instructions and instructions for use for outdoor blinds & exterior Venetian blinds for additional information and notes regarding HELLA outdoor blinds & exterior venetian blinds.
The following symbols will assist you with the installation or use and require a safetyconscious conduct:
Attention! This symbol indicates instructions that, if disregarded, can put the user in danger.

Attention!
This symbol indicates instructions that, if disregarded, can potentially result in damage to the product.

This symbol indicates instructions for use or helpful information.

This symbol requires you to act.

Attention!

This symbol indicates a risk of injury or danger to life due to an electric shock.

This symbol indicates parts of the product, for which you will find important information in these installation instructions.

Attention! This symbol indicates possible risk of injury by crushing.

This symbol indicates the cleaning of the product.

This symbol indicates the maintenance and repair of the product.

Subject to technical modifications ­ Date of Issue

3

September/2023

Installation Instructions
Before installation
Check the product immediately for possible shipping damage and for compliance with the delivery receipt.
If parts are missing or damaged, please consult your supplier immediately.
Check the mounting base and ensure that the mounting material to be used complies with the given conditions to guarantee proper installation. In case of doubt, please seek advice from a specialist enterprise for fixing techniques. The packaging cardboard box should not be exposed to humidity. To protect it from rain during transport, it should be covered by a foil. Carry larger units by two persons. Transport and store the units carefully to prevent injury of persons and damage to the product.
Remove the packaging material carefully. When using a knife, be careful not to damage the packaging content and to avoid cuts!
Dispose of the packaging material via recycling.
Caution! A wrong installation can endanger the user seriously. Please strictly observe the installation instructions. Close off the place of installation. When working at higher heights, there is risk of falling. Suitable ascent supports, scaffoldings and fall protection devices are to be used. Please make sure that the ascent supports stand solidly and provide a firm grip.

4

Subject to technical modifications ­ Date of Issue

September/2023

Installation Instructions
Overview: Tools for the installation

Battery-powered drill
Depending on the mounting base (bit holder AW 20, AW 25) Bit extension

Drill
Drill set acc. to mounting base

Bit holder AF 3/8 inch

Level

Measuring tape

Pin

Torx screwdriver TX25 - also possible AW20

Allen key 4 mm

Blind rivetting tongs for ø3.2 mm rivets

Subject to technical modifications ­ Date of Issue

5

September/2023

Installation Instructions
Overview: Model aluminium duct with screen ­ VA or with plaster base ­ VAP
1
2

3

11 10 9 8

7 6

Legend Aluminium duct Lateral covering Sealing profile Covering cap for guide rail End cap for bottom rail Bottom rail

5

4

Slat Lift tape Ladder cord Guide rail Guide rail insert

6

Subject to technical modifications ­ Date of Issue

September/2023

Installation Instructions

Type overview

Model aluminium duct with screen angular - VA7

Standard
KT

with duct insulation

DK

KT

Special duct dimensions according to order. Minimum duct height = 150 mm, maximum duct height = 370 mm (280 mm with KT = 110 mm)

RV H
RV H

Model aluminium duct with screen chamfered ­ VA9

Standard
KT 25

with duct insulation

DK

KT

25

Special duct dimensions according to order. Minimum duct height = 150 mm, maximum duct height = 370 mm (280 mm with KT = 110 mm)

RV 50
H RV
50 H

Standard duct dimensions:
KT = 120 mm / 150 mm / 160 mm H = 200 mm / 240 mm / 280 mm RV = 20 mm, upon request from 3 mm to 60 mm DK = 20 mm / 40 mm

Legend
KT Channel depth H Channel height RV Rear shortening DK Insulation body

Subject to technical modifications ­ Date of Issue

7

September/2023

Installation Instructions

Type overview

Model aluminium duct with plaster base ­ VAP

Standard
KT

with duct insulation

PT

DK

KT

PT

Special duct dimensions according to order. Minimum duct height = 150 mm, maximum duct height = 370 mm (280 mm with KT = 110 mm)

RV H
RV H

PN

PN

Standard duct dimensions:
KT = 110 mm / 140 mm / 150 mm H = 200 mm / 240 mm / 280 mm RV = 20 mm, upon request from 3 mm to 60 mm DK = 20 mm / 40 mm PT = 10 mm, upon request from 20 mm or without plaster base PN = 5 mm or 20 mm, special lengths between 5 mm and 80 mm (without plaster base the minimum plaster flange is 10 mm)

Legend
KT Channel depth H Channel height RV Rear shortening DK Insulation body PT Plaster base PN Plaster flange

8

Subject to technical modifications ­ Date of Issue

September/2023

Installation Instructions
Installation in general

1

2.

1.

3. 4.

LL

FB

4

LB

Check the dimensions of the element and wall opening, and the dimension of the window respectively. Measure the dimension of the cable duct for the drive system at the box and provide the appropriate wall or window duct. 1. Push the guide rails onto
the struts until the stop position is reached. Do not damage the slat guiding nipples. Make sure that the guide rails are at the same height. 2. Screw-down the countersunk screws to fix the box to the guide rail. 3. Hold the unit to the mounting base, adjust it and mark the boreholes through the guide rails on the mounting base. Provide the boreholes according to the mounting material to be used. Put the motor cable through the wall or window duct already provided and fix the element to the structure. 4. Place the covering caps in the bore holes in the guide rails.
Legend
Countersunk screw M5 x 16 mm
FB Complete width
LB Clear width
LL Slat length

Subject to technical modifications ­ Date of Issue

9

September/2023

Installation Instructions
Installation of the guide rail insert
Press the guide rail insert into the chamber of the guide rail.
Move the guide rail insert over all slat guiding nipples towards the top. (A slight bending of the guide rail insert eases the installation.)
All slat guiding nipples must be placed inside the guide rail insert.
The recess areas in the guide rail insert must be at the bottom side. (Locking with pins of the guide rail covering cap.)

10

Subject to technical modifications ­ Date of Issue

September/2023

Installation Instructions
Mounting the installation lug
1
1 2 3 4
1 2 3 4

The enclosed fastening lugs serve as an additional safeguard of the plaster base box and suppress the formation of cracks in the plaster.
Depending on the installation situation, screw the installation lugs to the box and the surrounding brickwork. Lift the box slightly at the front before mounting the installation lug.
If the installation lug is bended, mount the self drilling head screw and the screw for the mounting base as near as possible to the wrapping of the installation lug. The distance between the self drilling head screw and the upper edge of the box should be as small as possible.

Legend Mounting lug Dowel SX 8 Pan head screw ø4.5x50 mm Self drilling head screw with collar ø4.2x16 mm

Subject to technical modifications ­ Date of Issue

11

September/2023

Installation Instructions
Installation insect screen rail for integrated moscita insect roller screen
The insect screen is already pre-assembled in the plaster base box.

With motor drive

Installation of the insect screen according to the enclosed installation instructions for outdoor blinds / exterior Venetian blinds. (Chapter "Installation guide rail FUP70 / FUP80 / FUP95 installation insect screen")

With crank handle drive
14,5
1 2

Do not remove the tear tape from the guide rail! Screw down the insect screen guide rail laterally through the drilled holes to the guide rail FUP95. Fix the insect screen rail in such a way that it is flush with the lower edge of the guide rail. 1 self drilling head screw / bore hole in the insect screen rail
Legend
Tear tape Self drilling head screw ø4.2x22 mm
Installation Easy-Click see accompanying installation instructions for outdoor blinds / exterior Venetian blinds.

12

Subject to technical modifications ­ Date of Issue

September/2023

Installation Instructions
Commissioning/functional check
Extend and retract the unit in and out completely. When extending the unit for the first time, make sure no one is in the operating radius or standing below the unit.
Make sure that during the later operation the units can be extended freely and without blockings. Do not extend the unit, if objects or persons are in the operating radius of the sun protection unit. Please observe the safety instructions. After the first extending check the mounting material and the construction elements for strength. Automatic control devices or switches, that are not in the operator's field of vision, may not be used for test runs of motor driven units.
We recommend the use of a test cable for the provisional operation of the motor.
Check all settings. Check all screwed connections for tightness.
Double-check the grip of the supports on the mounting base.
Attention! An insufficient fastening of the mounting brackets can cause the collapsing of the unit; there is risk of injury or danger to life!
Clean the elements (see maintenance instructions).
Pass these instructions as well as possible instructions of the motor, switch and control manufacturer on to the user. Brief the user, whereupon you provide comprehensive information on the safety and user instructions of the system. Have the correct design of the system as well as the installation and briefing with the safety information confirmed in writing (see handover report).

Subject to technical modifications ­ Date of Issue

13

September/2023

Installation Instructions
Removal
Switch the unit dead and take safety precautions against unintentional switching on. The removal is carried out in reverse order to the installation.

14

Subject to technical modifications ­ Date of Issue

September/2023

Installation Instructions

HELLA Interior Venetian Blinds
regulate the lighting in a room very comfortably, immediately gracing it with much more atmosphere.

HELLA Insect screens
and you decide who is allowed to come in and who isn't.

HELLA Pleated Blind
folds up very compactly and protects very well against the sun and nosey glances where only little space is available.

HELLA Outdoor Blinds

HELLA Front-mounted

HELLA Vertical awning

serve for the light

Roller Shutter

With toggle catch

regulation, as view

for more safety and

mechanism for a lovely

protection, anti-glare blind protection against rain, façade design with perfect

and heat protection.

wind, heat, the cold, noise, heat and glare protection.

incident light and nosey

glances, also available for

subsequent installation.

For questions, wishes and ideas: HELLA Infoline +43/(0)4846/6555-0
HELLA Sonnen- und Wetterschutztechnik GmbH A-9913 Abfaltersbach, No. 125 Phone: +43/(0)4846/6555-0 Fax: +43/(0)4846/6555-134 e-mail: office@hella.info Internet: http://www.hella.info



References

PDFsharp 1.50.4000 (www sharp.com) (Original: Adobe PDF Library 23.3.60)