User Manual for TRIPLETT models including: SFM500, SFM500 Static Field Meter, SFM500, Static Field Meter, Field Meter, Meter

TM-181 Hygro-Thermometer說明書

administrator

Manual218.94 KB

Triplett SFM500 Static Field Meter with 4.5-Digit LCD, -19kV to 19kV

PDF preview unavailable. Download the PDF instead.

triplett sfm500 manual b49c
Test Equipm ent Depot - 800.517.8431 - 5 Commonwealth Ave, MA 01801 Test Equipm ent Depot .com
SFM500
Static Field Meter

Contents
1 Introduction ........................................................ 1 2 Accessories ....................................................... 1 3 Safety Precaution .............................................. 1 4 Instrument Description ....................................... 2 5 Operation ........................................................... 3
5-1 Disable Auto Power Off Mode.................... 4 5-2 Zeroing....................................................... 4 5-3 Manual record mode.................................. 4 5-4 Display logs mode ..................................... 5 5-5 Backlight Mode .......................................... 5 5-6 Setting mode.............................................. 5 6 Specifications..................................................... 7 7 Maintenance or Repair ...................................... 8 8 Battery Replacement ......................................... 8 9 Product Disposal................................................ 8

1 Introduction
This contactless precise electrostatic field meter can immediately sensor the static voltage on a charged body without contact. The measuring range is 0.010kV ~ 20.000kV with a sensing distance of 1 inch (2.54cm). The meter provides an alarm function for prompt.

2 Accessories

1

Meter

1

User's Manual

1

9V alkaline battery

1

Carrying case

3 Safety Precaution
Caution! Please refer to this manual. Improper use may damage the meter and its components.

Complies with European Directive.
 Do not operate in environments with flammable gas or humid environments.
 Operating altitude: up to 2000M.  Operating environment: Indoor use; Pollution degree 2.  Clean with soft cloth when dirty, such as glasses cloth.
Do not clean with chemicals and other solvents.  EMC: EN61326-1:CISPR 11:Group 1, Class B  Class B ­ Equipment for use in all establishments other
than domestic.  Group 1 ­ RF energy generated is needed for internal functioning.

1

4 Instrument Description

1. Sensor 2. LCD display 3. +peak value (max.
value) 4. -peak value (min.
value) 5. Zero setting button 6. Power button 7. Function Setting button 8. Record readings / up
button 9. Display logs / down
button

10. Data hold 11. Backlight button 12. Grounding socket 13. Tripod nut 14. battery cover 15. Grounding wire 16. Crocodile clip 17. Protection cap

2

5 Operation

Warning
The meter must be securely grounded
during measuring, and the holding
position not close to the sensor so to
avoid the risk of electric shock.
 Before use, the meter must be grounded. Please choose one of the following two methods to ground the meter: 1. The first method is connecting the meter's ground
socket with one end of the grounding wire of accessory and connecting to the earth end of the building with another end of the grounding wire, or connecting to the electrical socket for earthing, or clamping the earth end with a crocodile clip. 2. The second method is the operator wears the anti-static wrist strap and connects to the earth end of the building with another end of the anti-static wrist strap. Note that the anti-static wrist strap is not an accessory and should be prepared by yourself.  During the measuring for static voltage, please fasten ceramic spacers on the fix-threads beside the sensor. Keep the sensor from the area under test for 1 inch (2.54 cm).

 Click the

Power button.

 Make sure the meter is grounded before operating.

 Aim the sensor point to the area under test, keeping

your fingers away from the area under test as possible.

 Read the value (static voltage value) on the LCD.

 As completing a measurement, click the

button

to lock the reading permanently to hold the reading on the

LCD for a long time; click the

button again to unlock

3

to unlock the reading.

 Click the

button to continuously update the

maximum measuring value on the LCD to keep the +peak

value (max. value), click the

button again to cancel.

 Click the

button to continuously update the

minimum measuring value on the LCD to keep the -peak

value (min. value), click the

button again to cancel.

5-1 Disable Auto Power Off Mode
The meter will automatically power off after powering on for about 15 minutes. The LCD

displays symbol at the mode. If to disable

the function, press and hold the more than 2 seconds.

button for

5-2 Zeroing
 Prior to measuring the static voltage, click the button for more than 2 seconds to clear the reading if an old reading survived on the LCD. (Note: Set the static voltage of the surrounding environment to be 0, if not, the measuring may be biased.)

5-3 Manual record mode

 At measuring mode, click

button to record the

present reading, the records can be logged up to 99.

4

5-4 Display logs mode

 At measuring mode, click

button to display the

readings of logged data while MEM symbol appears on

the LCD. Click

button again to quit the mode. Click

button or logs.

button to select the number of

5-5 Backlight Mode

 During measuring, click

button to turn on the

backlight of LCD for 15 seconds and then turn off

automatically.

5-6 Setting mode

Press

button repeatedly and enter the settings of

Step 1 to 4 sequentially.

Step 1. Set (HI) + alarm

1. While the LCD displays SET1 HI symbol, Press

or

to move digits, press

or

button to change the settings.

2. Quickly press button again and enter Step 2.

Step 2. Set (LO)- alarm 1. While the LCD displays SET2 LO symbol, Press

or to move digits, press

or

button to change the settings.

2. Quickly press button again and enter Step 3.

5

Step 3. Set the alarm on or off

1. While the LCD displays SET3 and symbols,

press

or

or OFF.

button to change as

2. Quickly press button again and enter Step 4.

Step 4. Clear memory 1. While the LCD displays SET4 dEL symbol, press

or

button to change as

or

. As

is chosen, press

button to get memory cleared.

2. Quickly press button to quit the settings status.

PS: If to quit the settings status, press button in any step.

6

6 Specifications
 Display for readings: Liquid crystal display (LCD) of 4 1/2 digits with the displaying value up to 19999.
 Resolution: 0.001KV.  Measuring range-19.999KV+19.999KV  Accuracy: ±(5%+10dgt).  Overloading indication: OL.  Sampling period: 2 times per second.  Battery: 9V NEDA 1604IEC 6F22 or JIS 006P.  Battery life: Approximately 100 hours.  Operation temperature and humidity: 5 to 40oC (41
to 104oF); < 80%RH.  Storage temperature and humidity: -10ºC to 60ºC
(14 to 140 oF), < 70%RH.  Weight: Approximately 210g.  Dimension: 148(L)x65(W)x37.5(H)mm.  Professional and precise static voltmeter with
resolution of 0.001kV.  Function including Data lock (HOLD), Max. value
(+PEAK) lock, Min. value (-PEAK) lock, Record (REC) the displayed value, Display the logged data (R-M), Zeroing (ZERO)  High voltage alarm:+/- 18.000KV  Alarm setting:0.001KV18.000KV  Auto power off (for about 15 minutes).  Battery low display .  Overload display OL.
7

7 Maintenance or Repair
1. When the When symbol is displayed on the LCD, it means that there is insufficient power; please change the battery immediately in order to ensure its accuracy.
2. Do not place the meter in locations that have high temperature, humidity or that are exposed to direct sunlight.
3. Remember to turn off the power after usage; remove the battery if not used for a long period of time in order to prevent battery leakage and causing damage to internal components.
4. When the instrument failure, only by the authorized service provider or return the original repair.
8 Battery Replacement
1. Turn off the power. 2. Open the battery cover at the back of the meter,
remove the batteries. 3. Please insert six new 9V batteries according to the
polarities. 4. Put the battery cover back in place.
9 Product Disposal
Note: This symbol indicates that the meter and its accessories must be separated and processed properly.
8

Test Equipm ent Depot - 800.517.8431 - 5 Commonwealth Ave, MA 01801 Test Equipm ent Depot .com


Microsoft Word for Microsoft 365