Rotenso Airmi Monoblock Product Fiche
Rotenso
General Information
Supplier's name or trademark: Rotenso
Supplier's model identifier: AIMB160X3 R14
Temperature application: 35°C, 55°C
Contains fluorinated greenhouse gases.
Importer: THERMOSILESIA, ul Szyb Walenty 16, 41-700 Ruda Śląska, Poland
Manufacturer: ROTENSO, ul Szyb Walenty 16, 41-700 Ruda Śląska, Poland
Technical Specifications
Parameter | Unit | 35°C | 55°C |
---|---|---|---|
Seasonal space heating energy efficiency class | - | A+++ | A++ |
Rated heat output, including the rated heat output of any supplementary heater | kW | 14.9 | 12.8 |
Seasonal space heating energy efficiency (average climate) | % | 192.0 | 143.0 |
For space heating, annual energy consumption (average climate) | kWh | 6326 | 7238 |
Sound power level (Indoors) | dB | - | - |
Sound power level (Outdoors) | dB | 67 | 68 |
Rated heat output (colder climate conditions) | kW | 13.7 | 11.0 |
Seasonal space heating energy efficiency (colder climate conditions) | % | 156.0 | 114.0 |
For space heating, annual energy consumption (colder climate conditions) | kWh | 8488 | 9273 |
Rated heat output (warmer climate conditions) | kW | 15.6 | 14.4 |
Seasonal space heating energy efficiency (warmer climate conditions) | % | 265.0 | 173.0 |
For space heating, annual energy consumption (warmer climate conditions) | kWh | 3112 | 4367 |
[1] Annual energy consumption means the energy consumption required to meet the reference annual heating demand for the designated heating season in accordance with EU Regulation No. 811/2013.
Safety and Environmental Information
Precautions: Any specific precautions that shall be taken when the space heater is assembled, installed or maintained: Before any assembly, installation and maintenance, read the assembly and operating instructions for the unit and follow the information contained therein.
Environmental Impact: Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1kg of CO2 over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
Contains fluorinated greenhouse gases.
Note: Please check the above information on the appliance matches the model name on the nameplate.