Instruction Manual for TIMEGUARD models including: LEDPROSLB Outdoor LED Floodlight Plug, LEDPROSLB, Outdoor LED Floodlight Plug, LED Floodlight Plug, Floodlight Plug
LEDPROSLB Timeguard Dedicated PIR Detector, 180°, 12m, LEDPRO Floodlights, IP55, Black | YESSS Electrical
File Info : application/pdf, 12 Pages, 3.52MB
DocumentDocumentIInnssttaalllal atitoi onn&&OOp pe reartai nt ign gInIsnt rsutcr tuicotni os n s Dedicated PIR Professional LEDPROSLB & LEDPROSLWH 1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety off. 3. Technical Specifications 1 Dimensions 78 108 114 TOP VIEW A 180° Dusk Level Adjust C Delay Time Adjust SIDE VIEW 12 B D Lens Sticker Less sensitive More sensitive Restrict Long Detection Restrict RHS Detection Restrict short Detection Restrict LHS Detection E Mains Supply Note: Isolation 'Switch Live' Switch 3 F 4. Selecting The Location angles as shown (see diagram A). to maintain coverage and forward coverage will be reduced. diagram A detailing detection range and direction. 4 may cause false activation under extreme conditions. During extreme weather conditions the motion sensor may exhibit unusual behaviour. This 5. Installation G *** IMPORTANT *** Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. Locking bar Jumper Plug bar with one with the other to reconnect). 5 CONNECTION mains supply cable N L cable from the slave lighting load to the terminal block on the N L1 6. Commisioning and Operation Walk Test Procedure The unit can be set up in daylight or at night. seconds. This indicates the unit is wired correctly. The unit is in Automatic Mode when the light turns off. Setting Up For Automatic Operation 6 setting between these limits. each adjustment to try to get the unit to detect as above. 7. Masking The Sensor Lens sensor lens using the lens mask sticker supplied (see diagram D). range. Similarly the left and right lens sections cover the left and right detection area respectively. 8. Manual Override Mode 17 procedure. 9. Detector Head Adjustment The detector head can be panned 90° to the right and 90° to the left. 90° 90° Tilt down 10. Accessing Terminals After Installation This may be necessary to add further lighting for instance and the following procedure for removing the unit from its backplate should be followed:Insert the wire through the hole indicated in diagram F. The terminals are now accessible. If adding lighting, ensure the unit's rating is not exceeded. If you experience problems refer to Troubleshooting Guide. If problems still exist, do not immediately return the unit to store. Telephone the Timeguard Customer Helpline 020 8450 0515 Qualified Customer Support Co-ordinators will be on-line to 8 assist in resolving your query. 11. Troubleshooting PROBLEM SOLUTION night and day. terminals may be transposed. night, or PIR keeps activation at random for no apparent reason The unit may be suffering from false activation. Cover the sensor lens completely with black PVC tape. This will prevent the sensor from "seeing" anything. If the unit now switches off after the set time duration and does not re-activate, this indicates that the problem was cause by false activation. The problem may be solved by slightly adjusting the direction/angle of the sensor head (see previous section). If however, the unit the unit is faulty and should be replaced. You may not be allowing the unit time to complete it's warm-up period. Stand well out of the detection range and wait (the warm-up period Sometimes passages between buildings etc. can cause a "wind tunnel" effect. Ensure the unit is not positioned so as to allow detection of cars/people using public throughfares adjacent to your property. Ensure that the unit is mounted securely, even the slightest movement can result in a false detection. PIR sensor will not operated UIT at all. breaker/internal wall switch. wiring connections as per the diagram (see diagram E). Ensure no connections are loose. 9 Check the bulb. If the bulb has failed, replace (do not hold bulb directly with fingers, use a tissue or clean dry cloth). Ensure that the bulb is seated correctly in the bulbholder. The PIR sensor will not operate at night. Refer to section 4 for DUSK control adjustment. Unit activates during the daytime. Refer to section 4 for DUSK control adjustment. PIR coverage is poor/ sporadic. Unit may be poorly located. See previous section-"Selecting The Location" and re-locate the unit. Detection range varies from day to day. PIR sensors are influenced by climatic conditioins. The colder the ambient temperature, the more effective the sensor will be. You may need to make seasonal adjustments to the sensor head position to ensure trouble-free operation all year round. 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year, telephone the helpline on 020 8450 0515 . agreed by Timeguard) the customer is responsible for all shipping/postage charges is sent. 10 If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline@timeguard. com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com www.timeguard.com 67.058.563 (issue 2)