March 815-C series
815 Center Inlet

DESCRIPTION & OPERATION: 815 Center Inlet Series hot water booster centrifugal magnetic drive pumps are built to handle liquid transfer in heating and cooling operations. Contact the factory for application assistance. Pumps are not self-priming, lack a suction lift, and thus require a flooded suction. Pumps cannot be run dry.
INSTALLATIONS: Pumps should be installed with the pump housing arrow pointing in the direction of flow within the system. If the arrow indicating flow is not in the direction required, remove the housing screws holding the housing to the motor bracket and rotate the housing assembly as required. Replace the screws and tighten. The pump is composed of a wet end assembly which can be separated by unscrewing the housing screws. The pump will then separate into 2 parts. The liquid will be contained within the wet end assembly unless the rear housing screws on the rear housing are loosened.
GENERAL SAFETY INFORMATION: Follow all local safety codes & the Occupational Safety and Health Act (OSHA). Make certain that the power source conforms to the requirements of your equipment. Always disconnect power source before performing any work on or near the electric motor. Caution must be exercised to relieve any pressure in the system & in draining hot water from the pump or the system.
ELECTRICAL: Motors are available in different electrical configurations such as 115V 60 Hz or 230 Volt 50/60 Hz, 1 Phase. The motors are U.L. listed and rated for continuous duty. The 115V has a 6 foot cord and plug, the 230V has a 3 foot cord.

Specifications Product
Inlet-Outlet Max Internal Pressure Max Liquid Temperature
Max Flow

115V 230V

815-BR-C

815-PL-C

0809-0017-0400

0809-0188-0100

0809-0017-0500

0809-0188-0200

3/4"MPT-1/2"MPT 3/8"FPT & 3/4"MPT-1/2"MPT

150PSI (1034 kPa)

50PSI (344 kPa)

250F (121C)

250F (121C)

60Hz

Max Head

Electrical

815-SS-C 0809-0198-0100 0809-0198-0200 3/4"MPT-1/2"MPT 150PSI (1034 kPa)
250F (121C)
Max Flow

Max Head

50Hz

Electrical

Packed

Model GPM LPM FT PSI M Ph

V

A

HP

kW RPM GPM LPM Feet PSI M Ph

V

A

HP kW RPM Pounds

815-BR-C 815-PL-C 815-SS-C

8 30.3 18.6 8 5.7 1 115 or 230 0.5 or 0..3 1/25

0.029 3450 7.9 30 13.5 5.8 4.1 1 115 or 230 .0.4 or 0.3 1/25 0.029 2850

6

8 30.3 18.6 8 5.7 1 115 or 230 0.5 or 0..3 1/25

0.029 3450 7.9 30 13.5 5.8 4.1 1 115 or 230 .0.4 or 0.3 1/25 0.029 2850

5

8 30.3 18.6 8 5.7 1 115 or 230 0.5 or 0..3 1/25

0.029 3450 7.9 30 13.5 5.8 4.1 1 115 or 230 .0.4 or 0.3 1/25 0.029 2850

6

All specifications & data are based on pumping water & are intended as a guideline only. Specifications may vary with different motors.

0809-0238-2000-REV 3.21.2022

Item Part Number

815-BR-C
QTY Description REQ

Item Part Number

815-PL-C
QTY Description REQ

A 0923-0003-1000 4 #8-32 x 1 Lg. Screw (Steel)

A 0923-0003-1000 4 #8-32 x 1 Lg. Screw (Steel)

B 0809-0142-0000 1 Pump Housing (Bronze)

B 0809-0179-0100 1 Pump Housing (Polysulfone)

C 0809-0165-1000 1 D 0809-0043-1000 1

0.070 CS x 2.441 ID O-Ring (Silicone) Thrust Washer (Teflon)

C 0809-0027-1000 1 1/16 CS x 2-3/8 ID O-Ring (Silicone) D 0809-0043-1000 1 Thrust Washer (Teflon)

F 0809-0214-1000 1 Left-Hand Thread (Stainless Steel)

E 0809-0161-1000 1 "D" Flat Shaft ( Stainless Steel)

G 0809-0107-0200 1 H 0809-0012-1000 1 I 0135-0040-1000 8 J 0125-0083-0100 1 K 0858-0004-1000 4 L 0809-0058-1000 1 M 0809-0218-1000 1 N 0809-0124-1000 1
A 0809-0205-1000 4 B 0809-0150-0010 1 C 0809-0165-1000 1 D 0809-0043-1000 1 F 0809-0214-1000 1 G 0809-0107-0200 1 H 0809-0012-1000 1 I 0135-0040-1000 8 J 0125-0083-0100 1 K 0858-0004-1000 4 L 0809-0058-1000 1 M 0809-0218-1000 1 N 0809-0124-1000 1

2-5/32" Impeller (Ryton/Teflon/Glass) Rear Housing (Stainless) #8-32 x 3/8Lg. Screw (Stainless) Drive Magnet #8 Washer (Stainless) Motor Bracket (Plastic) Motor 115V, 50/60Hz, 6 foot cord and plug Motor 230V, 50/60Hz, 3 foot cord
815-SS-C #8-32 x 1 Lg. Screw (Stainless) Pump Housing (Stainless Steel) 0.070 CS x 2.441 ID O-Ring (Silicone) Thrust Washer (Teflon) Left-Hand Thread (Stainless Steel) 2-5/32" Impeller (Ryton/Teflon/Glass) Rear Housing (Stainless) #8-32 x 3/8Lg. Screw (Stainless) Drive Magnet #8 Washer (Stainless) Motor Bracket (Plastic) Motor 115V, 50/60Hz, 6 foot cord and plug Motor 230V, 50/60Hz, 3 foot cord

G 0809-0107-0200 1 2-5/32" Impeller (Ryton/Teflon/Glass) H 0809-0012-1000 1 Rear Housing (Stainless) I 0135-0040-1000 8 #8-32 x 3/8Lg. Screw (Stainless) J 0125-0083-0100 1 Drive Magnet K 0858-0004-1000 4 #8 Washer (Stainless) L 0809-0058-1000 1 Motor Bracket (Plastic) M 0809-0218-1000 1 Motor 115V, 50/60Hz, 6 foot cord and plug N 0809-0124-1000 1 Motor 230V, 50/60Hz, 3 foot cord LUBRICATION: The motor should be oiled at least once a year at the start of the heating season with 4 or 5 drops of SAE 20 weight non-detergent oil in each bearing. If the pump is used daily, it should be oiled every six months. Do not over oil.
DISASSEMBLY & REASSEMBLY: The motor can be removed from the wet end assembly without draining the liquid from the system. To do so remove four housing screws and slide the motor assembly away. If parts inside the wet end assembly must be removed, isolate the pump or drain the system. When the system is drained and cool, remove the four screws from the rear of the housing. The rear housing can now be removed. Remaining pump parts can be removed. Replace any worn or damaged parts. Replace the O-ring anytime the rear housing is removed.
Materials in contact with the liquid: 815-BR-C: Bronze, Stainless Steel, Ryton/Teflon/Carbon, Silicone, Teflon 815-PL-C: Polysulfone, Stainless Steel, Ryton/Teflon/Carbon, Silicone, Teflon 815-SS-C: Stainless Steel, Ryton/Teflon/Carbon, Silicone, Teflon

NOTE: Contact Factory for other materials and/or parts not listed.

Special voltage motors are available upon special order.

LIMITED WARRANTY: March pumps are guaranteed only against defects in workmanship or materials for a period of one year from date of manufacture pumping water. For the complete warranty and to register online go to www.marchpump.com/warranty-registration