User Guide for FS models including: S3950 Series, S5800 Series, S5850 Series, S8050 Series, S8550 Series, S5850-48T4Q, S5850-48S6Q, S5850-32S2Q, S5850-48S2Q4C, S8050-20Q4C, S5850-24T16S, S5850-24T16B, S5800-48F4SR, S5800-48T4S, S5850-24S2Q, S5850-24S2C, S5800-8TF12S, S3950-4T12S, S5850-24XMG, S5850-24XMGU, S8550-6Q2C, S5800-48MBQ, S5850-48T4Q-PE, S3950 Series Switches Enable Web Management Configuration, Switches Enable Web Management Configuration

S5850 and S8050 Series Switches Enable Web Management Configuration Guide丨FS

This user manual is designed to guide you through the configuration guide.

Multi-Port Gigabit Ethernet Switch, Data Center TOR Switch, LAN Distribution Switch

FS - Fiberstore

S3950 and S5800 and S5850 and S8050 and S8550 Series Switches Enable Web Management Configuration Guide

S5850 - FS.com

S5850 and S8050 Series Switches Enable Web Management Configuration ...

S5850AND S8050 SERIES SWITCHES ENABLEWEBMANAGEMENT CONFIGURATION GUIDE 48F4SR www.fs.com 1 S3950&S5800&S5850&S8050 Series Switches Enable Web Management Configuration

S5850 and S8050 Series Switches Enable Web Management Configuration Guide丨FS


File Info : application/pdf, 5 Pages, 263.10KB

PDF preview unavailable. Download the PDF instead.

20221110170819ddftre
S3950&S5800&S5850&S8050 Series Switches Enable Web Management Configuration S5850 AND S8050 SERIES SWITCHES ENABLE WEBMANAGEMENT CONFIGURATION GUIDE
S3950&S5800&S5850&S8050&S8550 Series Switches Enable Web Management Configuration
Models: S5850-48T4QS5850-48S6QS5850-32S2QS585048S2Q4CS8050-20Q4CS5850-24T16SS5850-24T16B S580048F4SR S5800-48T4S S5850-24S2Q S5850-24S2C S58008TF12S S3950-4T12S S5850-24XMG S5850-24XMGU S8550-6Q2C S5800-48MBQ S5850-48T4Q-PE

www.fs.com

1

S3950&S5800&S5850&S8050SERIES SWITCHESENABLEWEBMANAGEMENTCONFIGURATIONGUIDE
Content
1. Introduction ........................................................................................................................................................... 1 2. Topology............................................................................................................................................................... 1 3. Configuration Steps .............................................................................................................................................. 1
www.fs.com

S3950&S5800&S5850&S8050SERIES SWITCHESENABLEWEBMANAGEMENTCONFIGURATIONGUIDE
1. Introduction
This document explains in detail how to turn on the relevant content of the Web, and it is only available for Web management with version numbers V7.4.3.r3 and below.
2. Topology
3. Configuration Steps
(1) Connection equipment According to the way of networking topo to connect PC and S5850-48S6Q switch to network.One end of the RJ-45 cable is connected to the PC's network port, and the other end is connected to the Manage interface of S5850-48S6Q. At the same time, one end of console line USB is connected to PC's USB interface, and the other end of RJ-45 connector is connected to console interface of front panel of switch. (2) Download related software Search and install SecureCRT debugging software and Tftpd32 file transfer software through Google. (3) Configure software parameters Energizing the switch.Then right-click "my computer" on PC, click management, and view the com port corresponding to console cable from device manager. (If it display an unrecognized USB device, please download and install the corresponding driver). Then open SecureCRT, select the serial login mode, and select the serial number from the device manager. Baud rate is 115200, no flow control is selected. As the picture shows.

www.fs.com

1

S3950&S5800&S5850&S8050SERIES SWITCHESENABLEWEBMANAGEMENTCONFIGURATIONGUIDE
(4) Login switch After a successful connection, tapping the Enter key on the keyboard will jump out of the prompt to enter the account password. At this point, enter the default user name and password admin/admin, you can log in to the switch. Then use cd flash:/? command to see if a WebImage file exists in the system directory of the switch. As the picture shows, if this file exists, skip to Step 7.
S5850-48S6Q# cd flash:/?

(5) Configure Tftpd32 software
Open Tftpd32 software and set Server interfaces as the local IP address of the computer. Current Directory fills in the file path where the upgrade package is located. As the picture shows.

www.fs.com

2

S3950&S5800&S5850&S8050SERIES SWITCHESENABLEWEBMANAGEMENTCONFIGURATIONGUIDE
(6) Download WebImage Through Tftpd32 software,download WebImage to the root directory of the switch, flash:/. S5850-48S6Q# copy mgmt-if tftp://192.168.148.1/ FSOS-webImage-v7.4.3.bin flash:/
Note: The webImage version downloaded for S3950-4T12S and S5800-8TF12S is v5.3.11. S3950-4T12S# copy mgmt-if tftp://192.168.148.1/ FSOS-webImage-v5.3.12.bin flash:/ (7) Configuration switch management IP Configuration management IP for Management interface of switch under CLI interface S5850-48S6Q# configure terminal S5850-48S6Q(config)# management ip address 192. 168.100.6/24 S5850-48S6Q(config)# management route add gateway 192.168.100.1 S5850-48S6Q(config)#exit
(8) Enable Http services S5850-48S6Q# configure terminal S5850-48S6Q(config)# http server load flash:/FSOS-webImage-v7.4.3.bin S5850-48S6Q(config)# service http enable
Note: The webImage version downloaded for S3950-4T12S and S5800-8TF12S is v5.3.12. S3950-4T12S# configure terminal S3950-4T12S(config)# http server load flash:/FSOS-webImage-v5.3.12.bin SS3950-4T12S(config)# service http enable
(9) Enter Web interface
Enter the Administrator IP address:192.168.100.6 in the URL bar of Google Browser,then enter the default username and password admin/admin.As the picture shows.

NOTE: Recommended use of the latest version of WebImage files.