Instruction Manual for VEVOR models including: CH-360T Tool Sanitizer, CH-360T, Tool Sanitizer, Sanitizer

司顺工业设计


File Info : application/pdf, 12 Pages, 497.50KB

PDF preview unavailable. Download the PDF instead.

sku13~15-康之晴-工具消毒器-说明书-20250220 1744681697807
Tool Sanitizer
Technical Support and E-Warranty Certificate www.vevor.com/support

Model: CH-360T

Tool Sanitizer

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product.
-1-

Symbol Symbol Description
Warning: To reduce the risk of injury, the user must read the
instructions manual carefully.
This symbol, placed before a safety comment, indicates a kind of precaution, warning, or danger. Ignoring this warning may lead to an accident. To reduce the risk of injury, fire, or electrocution, please always follow the recommendation shown below.
CORRECT DISPOSAL: This product is subject to the provision of European Directive 2012/ 19/EC. The symbol showing a wheelie bin crossed through indicates that the product requires separate refuse collection in the European Union. This applies to the product and all accessories marked with this symbol. Products marked as such may not be discarded with normal domestic waste, but must be taken to a collection point for recycling electrical and electronic devices.
FCC INFORMATION CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment! This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This product may cause harmful interference. 2)This product must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this product not expressly
approved by the party.responsible for compliance could void the user's authority to operate the product.
-2-

SAFETY INSTRUCTIONS
WARNING: Do not expose eyes or skin to UV light.
1.The first time you use it, there will be white smoke coming out. This is a normal phenomenon. The white smoke will significantly decrease afterwards. 2.When using the sterilizer for the first time,operate it in an empty load mode for working cycle,then open the door for 20 minutes.This operation can eliminate any odd smell inside the cabinet. 3.Make sure to drain all water the utensils before placing them in the sterilizer.The utensils should not be stacked but placed vertically one by one to achieve the best sterilization effect. 4.In case of any abnormal conditions(such as unusual noise,odd smell,or smoke),immediately unplug the power cord of the sterilizer and contact the repair center or the manufacturer for inspection and repair.Do not use it again until the cause of the fault is resolved. 5.When maintaining or cleaning the device,make sure to unplug the power cord to ensure complete disconnection from the power source. 6.Wait for 10 minutes after the sterilization cycle completed before opening the door.Use the utensils only after they have cooled down to avoid affecting the sterilization effect or causing burns. 7.Do not install sterilizer near flammable materials. 8.If the power cord is damaged,it must be replaced by a professional from the manufacturer,its repair department,or similar department to avoid danger. 9.Do not place the sterilizer in areas prone to moisture or water splashes,and do not use heating appliances near the sterilizer,as this may cause deformation or malfunction of the sterilizer. 10.After use,if it will not be used for a long,please cut off the power and do not leave the power cord in a connected state to avoid danger. 11.It is strictly prohibited to directly rinse the with water or immerse the machine in water.
-3-

MODEL AND PARAMETERS

Model

CH-360T

Input

AC 110V 60Hz(US), AC 220-240V 50Hz(EU&AU)

Max. Power
Temperature setting Time setting Size

300W 0~220 5-60 min 349*193*175mm

STRUCTURE DIAGRAM

-4-

1.Handle 3.Handle 5.Power indicator light 7.Time adjustment knob

2.Tray 4.Temperature adjustment knob 6.Work indicating lamp 8.Electrical outlets
PARTS LIST

Tool Sanitizer x1

Tray x1

Power Cord x1

Ring x2 Fuse x1

User Manual x1 -5-

OPERATION METHOD 1.Please remove the protective film on the tray for the first use. 2.Plug the matching power source we provide. 3.Put your instrument to be sterilized on the tray and close the cover. 4.Adjust the time dial according to your requirement,activating the device.The red indicator will light on which means the device is under working mode.Next,adjust the temperature dial according to your requirement,and by now the green indicator will light on.Both of the lights will go out when the device has finished its work.Please note that neither of the indicator will light on if you only adjust the temperature dial.Generally speaking,all instrument and goods can be totally sterilized and disinfected in 15 minutes at 125 Celsius degrees. 5. Adjust the temperature by dialing the left hand knob.
6. Unplug the power supply after each use. 7. After sterilization,hook the ring onto the tray and fetch it out the device.
-6-

Maintenance
1.Make sure to unplug the power cord before cleaning or maintaining the disinfection cabinet. 2.Wear gloves cleaning or maintenance to prevent cuts from sharp edges inside the cabinet. 3.Regularly wipe off stains from the surface to keep the cabinet clean and attractive. 4.Electrical components must not be immersed in water.Do not rinse the cabinet with water. 5.Regular maintenance is recommended.Unplug the power cord,use a cloth with a small amountof neutral detergent to gently remove stains inside and outside the cabinet,then use a cleandamp cloth to remove the detergent. 6.When disinfection cabinet is not in use,it should be unplugged.If it is to be unused for a longtime,moved,or serviced,make sure unplug the power cord first. 7.If any abnormality occurs during use,stop using it immediately and unplug the power cord.Toavoid danger,installation or repair must be done by a qualified electrical repair person.

Common Fault Guidelines

Fault Description

Cause Analysis

Solution

The device is not powered on

The power cord is not Plug the matching power

plugged in

source we provide

The device is not functioning

The time adjustment Adjust the time adjustment knob is not adjusted knob

-7-

Manufacturer: Foshan Kangzhiqing Electrical Appliance Co.,Ltd Address: No.23-2,Liuyi San Road,Nanhai District,Foshan City,Guangdong Province, China Imported to AUS: SIHAO PTY LTD. 1 ROKEVA STREETEASTWOOD NSW 2122 Australia Imported to USA: Sanven Technology Ltd. Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730
YH CONSULTING LIMITED. C/O YH Consulting
UK REP Limited Office 147, Centurion House, London Road, Staines-upon-Thames, Surrey, TW18 4AX E-CrossStu GmbH
EC REP Mainzer Landstr.69, 60329 Frankfurt am Main.
-8-

Technical Support and E-Warranty Certificate www.vevor.com/support



References