i-hpsb ?abl version=10/18/2021 15:54:08&DOC Type=Installation Instruction Sheets
Installation Instructions Healthcare Lighting HPSB

Revision B

I-HPSB

Revision Date 10112021

HealthCare Lighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 www.acuitybrands.com

Page 1 of 4

LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
· To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
· Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. · Installation and service of luminaires should be performed by a qualified licensed electrician. · Maintenance of the luminaires should be performed by person(s) familiar with the luminaires' construction and operation
and any hazards involved. Regular fixture maintenance programs are recommended. · It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary. · DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. · Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. · These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's or owner's purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING RISK OF ELECTRIC SHOCK
 Disconnect or turn off power before installation or servicing.
 Verify that supply voltage is correct by comparing it with the luminaire label information.
 Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
 All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION RISK OF INJURY
 Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
 Avoid direct eye exposure to the light source while it is on.

WARNING RISK OF BURN  Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.  Do not exceed maximum wattage marked on luminaire label.  Follow all manufacturer's warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF FIRE  Keep combustible and other materials that can burn, away from lamp/lens.  Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

HealthCare Lighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 www.acuitybrands.com

Page 2 of 4

LED IMPORTANT SAFETY INSTRUCTIONS

CAUTION: RISK OF PRODUCT DAMAGE

 Never connect components under load.  Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.  Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the
luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be
powered directly off a switched circuit.  Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some
volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that
will prevent convection or conduction cooling.  Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient
temperature.  Only use fixture in its intended location.  LED products are Polarity Sensitive. Ensure proper Polarity before installation.  Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn
during all installation or servicing of the unit.  Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter
performance.  Some components inside the fixture may not be serviceable. In the unlikely event your unit may require
service, stop using the unit immediately and contact an ABL representative for assistance.  Always read the fixtures complete installation instructions prior to installation for any additional fixture
specific warnings.  Always ensure that the electrical distribution system is up to NEC (and any applicable local code)
requirements.  Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture
failure and may void warranty.

Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation

This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.
Fa ilure t o follow a ny of t hese inst ruct ions could void product w a rrant ies. For a com plet e list ing of product Te rm s a nd Condit ions, ple a se visit w w w .a cuit ybrands.com .

Our Brands

Indoor/Outdoor

Indoor Lighting

Outdoor Lighting

Controls

Daylighting

Lithonia Lighting

Aculux

American Electric Lighting

DARK TO LIGHT

SunOptics

Carandini

Gotham

Antique Street Lamps

LC&D

Holophane

Indy

Hydrel

ROAM

RELOC

Juno

Tersen

Sensor Switch

Light Concepts

Mark Architectural Lighting

Synergy

Peerless

Renaissance Lighting

Winona Lighting

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

HealthCare Lighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 www.acuitybrands.com

Page 3 of 4

Revision B

I-HPSB

Revision Date 10112021

Installation Steps:
1. Remove shade by removing the (2) battery nuts to release body subassembly 2. Remove (2) hex head flange nuts to release led lamp assembly. 3. Attach mount plant to contractor supplied j-box. 4. Make all necessary wire connections. 5. Reverse instructions to re-assemble.

Wiring: Black, White ­ Line Voltage (120/277V) Green ­ Ground Purple ­ 0-10V Dimming (+) Pink ­ 0-10V Dimming (-) For non-dimming installations, cap the purple and pink wires.