User Manual for EXTECH models including: Temperature and Humidity Datalogger, 42270
USER MANUAL Model 42270 Temperature & Humidity Datalogger Datalogger Memory Additional User Manual Translations available at www.extech.com Introduction Model 42270: Temperature and Humidity Datalogging Module Model 42275: 42270 Module, Docking station, Software CD This Datalogger can be used to monitor the temperature in
Additional User Manual Translations available at www.extech.com. Introduction. Model 42270: Temperature and Humidity Datalogging Module. Model 42275: ...
USER MANUAL Model 42270 Temperature & Humidity Datalogger Datalogger Memory Additional User Manual Translations available at www.extech.com Introduction Model 42270: Temperature and Humidity Datalogging Module Model 42275: 42270 Module, Docking station, Software CD This Datalogger can be used to monitor the temperature in
File Info : application/pdf, 1 Pages, 705.99KB
DocumentDocumentUSER MANUAL Model 42270 Temperature & Humidity Datalogger Additional User Manual Translations available at www.extech.com Introduction Model 42270: Temperature and Humidity Datalogging Module Model 42275: 42270 Module, Docking station, Software CD This Datalogger can be used to monitor the temperature in greenhouses, warehouses, food transports, aircraft cabins, refrigerated trucks, containers, museums, and HVAC equipment. The Model 42270 records Relative Humidity readings in addition to Temperature readings. Programming and data retrieval instructions are included on the Software CD located in the 42275 kit or at www.Extech.com. Description 1. Mounting hole 2. Status LEDs (Record and Alarm) 3. LCD display Displays LCD Display REC: HI and LOW: RH%: C or F: COMM: Displayed while logging readings. Displayed when the High or Low Alarm limit is exceeded. Relative Humidity Temperature units. Appears when Datalogger is communicating with a PC. Recording Status Indication Both the RED status LED and the display indicator `REC' will flash every 5 seconds if the sampling rate is set to 5 seconds or higher. If the sampling rate is set lower than 5 seconds, the indicators will flash every 1, 2, 3, or 4 seconds as programmed. ALARM Status Indication Both the YELLOW status LED and the display indicator `ALM' will flash when the recorded value is higher than the user programmed High Alarm value or lower than the Low Alarm value. The Alarm status LED and the `ALM' display indicator flash every 5 seconds if the sampling rate is programmed for 5 seconds or higher. If the sampling rate is set lower than 5 seconds, the indicators will flash every 1, 2, 3, or 4 seconds as programmed. Low Battery Indication When the lithium battery voltage nears the critical operating level, the LCD displays `LO'. To replace the battery, refer to the Battery Replacement section. Specifications Front panel status Temperature range Temp. Resolution Temperature accuracy RH range/accuracy Datalogger Memory Sampling rate Power supply Battery Life Low battery Indicator Dimensions LEDs (2): RECORD and ALARM -40 to 185°F (-40 to 85°C) 0.1° up to 99.9°; 1° from 100° to 185° ±1.2°F (0.6°C) from -4 to 122°F (-20 to 50°C) ±2.4°F (1.2°C) all other ranges 0.0 to 99.9% Relative Humidity; Accuracy: ± 3% 16,000 readings (8,000 temperature & 8,000 RH readings) Programmable from 1 second to 12 hours 3.6V ½ `AA' lithium battery (SAFT LS-14250) 1 year: 5-second sample rate in sleep mode 3.8 months: 24-hour sample rate in non-sleep mode Display shows `LO' 3 x 2.3 x 0.88" (76.2 x 57.2 x 22.3mm) Note: This datalogger cannot be used without the software and docking station included in the 42275 kit. At least one 42275 kit is required per site. Note: The datalogger display will not switch on until activated by software. Note: The 42270 readout may turn gray if the ambient temperature falls below 32°F (0°C). It may also darken and become unreadable if the ambient temperature exceeds 122°F (50°C). This is expected operation. In both cases, the unit will log readings normally and will continue to log throughout the specified temperature measurement range. Battery Replacement When low battery icon (`LO') appears, replace the Lithium CR2 battery. 1. Open Datalogger by first removing the four (4) rear Phillips screws. 2. Carefully pry off the rear of the Datalogger. 3. The cylindrical lithium battery is located on bottom of PCB board. 4. Replace the battery, observing polarity. 5. Assemble the Datalogger housing. Two-year Warranty FLIR Systems, Inc. warrants this Extech brand instrument to be free of defects in parts and workmanship for two years from date of shipment (a six-month limited warranty applies to sensors and cables). To view the full warranty text please visit: http://www.extech.com/support/warranties. Calibration and Repair Services FLIR Systems, Inc. offers calibration and repair services for the Extech brand products we sell. We offer NIST traceable calibration for most of our products. Contact us for information on calibration and repair availability, refer to the contact information below. Annual calibrations should be performed to verify meter performance and accuracy. Product specifications are subject to change without notice. Please visit our website for the most up-to-date product information: www.extech.com. Contact Customer Support Customer Support Telephone List: https://support.flir.com/contact Calibration, Repair, and Returns: repair@extech.com Technical Support: https://support.flir.com Copyright © 2014-2020 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 42270-en-US_v3.5 7/20