Installation Guide for NOTIFIER models including: AM2020, AM2020 Fire and Security Alarm Control Panel with DIA-2020 Display Interface, Fire and Security Alarm Control Panel with DIA 2020 Display Interface, Security Alarm Control Panel with DIA-2020 Display Interface, Alarm Control Panel with DIA-2020 Display Interface, Control Panel with DIA-2020 Display Interface, DIA-2020 Display Interface, Display Interface
Notifier AM2020 w-DIA-2020 Software Release Summary - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 4 Pages, 943.51KB
DocumentDocument12 Clintonville Road Northford, CT 06472-1610 203-484-7161 FAX: 203-484-7118 Software Release Summary for the Notifier AM2020 Fire/Security Control Panel with the DIA-2020 Display Interface Assembly AROM6N This document covers Release 6.0 Software as it affects the following ROMs: AROM6N-AMG AROM6N-DIA AROM6N-SIB AROM6N-CPU AROM6N-LIB AROM6N-XPP AROM6N-AMGX4 AROM6N-AMGZC AROM6N-LIB-B AROM6N-AMGZCF CAUTION - System Reacceptance Test after Software Changes: To ensure proper system operation, this product must be tested in accordance with NFPA 72-1993 Chapter 7 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. www.PDF-Zoo.com firealarmresources.com I1 Document 15414 07/18/97 Revision P/N 15414:I1 ECN 97-294 AROM6N Inventory List The following replacement ROMs must be ordered individually according to your system requirements. AROM6Ns cannot be used in conjunction with earlier ROMs. All system ROMs must be upgraded at the same time. (See Compatibility Warning) AROM6N-AMG (standard AMG operation at Annunciator address 29, 30, 31, or 32) Includes: EPROM for AMG-1/AMG-E Document # 15744 Document # 15889 "Field Change Procedure for the AM2020 and AFP1010" "Voice Alarm Multiplex-2020" AROM6N-AMGX4 (for use with 5th through 8th AMG in one system at Annunciator address 25, 26, 27, or 28) Includes: EPROM forAMG-1/AMG-E Document # 15744 Document # 15889 "Field Change Procedure for the AM2020 and AFP1010" "Voice Alarm Multiplex-2020" EPROM Part # AROM6N-AMG ---------- 73284 AROM6N-AMGX4 ------ 73295 AROM6N-AMGZC ----- 73529 AROM6N-AMGCF ------ 73534 AROM6N-CPU ----------- 73549 AROM6N-DIA ------------ 73547 AROM6N-LIB ------------ 73539 AROM6N-LIB-B -------- 73540 AROM6N-SIB ------------ 73496 AROM6N-XPP ----------- 73679 AROM6N-AMGZC (for zone coded AMG operation occupying addresses 2, 3, 4, and 5) Includes: EPROM for AMG-1/AMG-E Document # 15744 "Field Change Procedure for the AM2020 and AFP1010" Document # 15889 "Voice Alarm Multiplex-2020" AROM6N-AMGZCF (for zone coded AMG operation occupying addresses 2, 3, 4, and 5) Includes: EPROM for AMG-1/AMG-E Document # 15744 "Field Change Procedure for the AM2020 and AFP1010" Document # 15889 "Voice Alarm Multiplex-2020" AROM6N-CPU Includes: EPROM for CPU-2020 Document # 15744 Document # 15337 "Field Change Procedure for the AM2020 and AFP1010" "The AM2020/AFP1010 Fire Alarm Control Panel Operator's Instructions" AROM6N-DIA Includes: EPROM for DIA-2020 DIA-2020 Label Document # 15987 Document # 15744 Document # 15088 Document # 15088SUP 'LED Instruction Sheet' "Field Change Procedure for the AM2020 and AFP1010" "The AM2020/AFP1010 Manual" Supplement to Document 15088 AROM6N-LIB/AROM6N-LIB-B Includes: EPROM for LIB-200 Document # 15744 "Field Change Procedure for the AM2020 and AFP1010" AROM6N-SIB Includes: EPROM for SIB-2048 Document # 15744 "Field Change Procedure for the AM2020 and AFP1010" AROM6N-XPP Includes: EPROM for XPP-1 Document # 15744 Document # 15888 "Field Change Procedure for the AM2020 and AFP1010" "The XP Series Transponder System" 2 15414-I1 07/18/97 www.PDF-Zoo.com firealarmresources.com Field Change Procedure. (Document # 15744) provides instructions for mechanical replacement of the ROMs. DIA-2020 EPROM PROG. P/N 73547 DIA-2020 Label. Provides a quick reference to the ROM software level currently installed in the AM2020 DIA-2020 Assembly. Place this label on the inside of the DIA-2020 door during installation of the AROM6N-DIA. AC POWER FIRE ALARM TROUBLE/ SECURITY ALARM DISPLAY TROUBLE SIGNAL SILENCE 15454 Mylar Security LED Overlay When software is upgraded to this level, the label shown above must be placed over the existing DIA-2020 LED legend (if the existing legend differs from the above). AROM6N Special Features/Notes for the DIA-2020 Selectable Drift Compensation This feature makes the NFPA 72-1993, Chapter 6 sensitivity calibrated test for intelligent detectors software selectable. NOTE: When the software provided with this upgrade kit is installed, the NFPA 72-1993, Chapter 6 Sensitivity Calibrated Test and Drift Compensation features will be automatically disabled. The installer must re-enable Drift Compensation (See the AM2020/AFP1010 Programming Manual, Document 15334) in order to restore the NFPA 72-1993, Chapter 6 Sensitivity Calibrated Test and Drift Compensation features. UL1076/UL1610 Security This feature allows the AM2020/AFP1010 to act as a combination fire/security protective signaling system. The AM2020/ AFP1010 is suitable for use as a Grade AA, Grade A, or Grade B Central Station and Proprietary Burglar Alarm Protected Premises and Receiving Unit, only after all installation requirements outlined and programming guidelines described in the AM2020/AFP1010 manuals have been adhered to. This feature utilizes four new software type IDs: SARM, SACM, SSYM, and SEQM in addition to a new control-bytime function SDEL. UL864 Revised Standard for DACT Operation The Fire Alarm Control Panel must delay the reporting of A.C. power loss to the digital alarm communicator. A new software type ID, DACT, is used with a CMX control module to accomplish this. Zone Coded Voice For female zone coded voice, the AMG1 requires the installation of both an AROM6N-AMGZCF chip and a VROM135 chip. www.PDF-Zoo.com firealarmresources.com 3 15414-I1 07/18/97 Previous AM2020 Software Releases (The following features are included in the current software release) ROMSC1-2020 · Enhanced Time/Date Input Format · Keyboard Operation and Terminal Supervi sion · Disabling the Piezo Sounder · Enhanced READ STATUS Options · Finding the Parentheses Keys · Latching LEDs on the SLC Loop · Self-Restoring Initiating Device Troubles · Peripheral Communication Rate ROMSC2-2020 · Enhanced Read Status Option · System and Point Status Reports · Terminal Status Line Enabling · Detector Sensitivity Selection · Initiating Device Tracking Option · Software Type I.D. Grouping · Event-Pending Software Types · CPU/DIB Communications Failure Signal · P-80 Printer Troubleshooting Tip ROMSC3-2020 (Rev A) · Maintenance Alert · Low Chamber Value ROMSC3-2020 (Rev B, & C) · Maintenance Alert · Low Chamber Value · Display Monitor Capacity ROMSC3-2020 (Rev D) · Maintenance Alert. · Low Chamber Value · Display Monitor Capacity. · Hardware/Software Compatibility. AROM-4 (Rev A, B, C, D , E & F) · AMG-1 Address Change · ALL CALL Function · AMG-1 Functions · Dual Stage Operation (for Canada only) · XPP-1 Relay Mapping Change · Non-Latching Inputs · ISIB Isolation · Annunciators · CGAS, AMNET, and AUTOPLEXOR Compatibility Warning · History Mode · Disable · Control · Signal Silence/Signal Cut-out Times · Local Mode · Signal Silence Operation · Type I.D.'s · Time/Date · PRN-2 Paper Out/Off-line · NFPA · Terminal Beep AROM5 (Rev A) · Battery Charger Control · Block Acknowledge · Control-By-Time · Control Module Reporting · Day/Night Sensitivity · Device Blink · Disabled Zones · Event Reminder · Expanded Read Status Functions · Expanded Status Line · Expanded User Reports · LED Latching · Local Printer · New Type I.D.'s · NIB Trouble Reporting · Non-Alarm Module Reporting · Periodic Detector Test · Prior/Next/Autostep Keys · Remote Page · Upload/Download of AM2020 Programming · Verification Counter Reset · Walk Test AROM5 (Rev B - C) · Zone Coded Synthesized Chime · Zone Coded Voice AROM5 (Rev D - F) · New AMG Boards AROM5 (Rev G-I) · 72E Sensitivity Calibrated Test · Drift Compensation · Manual Reset of automatically activated control modules. AROM6N (Rev A-B) · Selectable Drift Compensation · UL1076/UL1610 Security AROM6N (Rev C-F) · Revised Standard for DACT Operation AROM6N (Rev G-H) · Zone Coded Voice (Female) Compatibility Warning Software Combinations: All software part numbers are not compatible with each other. Improper mixing of software part numbers may compromise LifeSafety functions. If in doubt about the compatibility of a particular software combination, consult the factory. CGAS, AMNET and AUTOPLEXOR This software is not compatible with earlier versions of CGAS, AMNET and AUTOPLEXOR systems. Software in these items must be upgraded for compatibility. 4 15414-I1 07/18/97 www.PDF-Zoo.com firealarmresources.com