Comfort-Aire ZHP Series Single Zone Heat Pump
An Artistic Combination of Efficiency and Performance
The ZHP Series emphasizes energy efficiency in a simplified, modern, and silent design.
Key Features
Highly Efficient
Achieves up to 35 SEER2 and 17.4 EER2 ratings.
Whisper Quiet
The high-technology fan in the indoor unit ensures balanced airflow.
Thermal Compensation
The indoor unit automatically adjusts to needs to eliminate stratification between ceiling and floor temperatures.
Auto-Vane
Continuous adjustment of the airflow direction, providing a gentle, breeze-like effect.
Multiple Modes
Includes Cooling, Dehumidification Only, Air Circulation, and Heat modes. Features include Sleep Mode, 24-Hour Timer, and Turbo Mode.
Auto Function
Automatically adjusts to maintain a constant temperature and humidity level.
Smartphone Compatibility
Optional 7800-208 smartphone control kit available separately.
Superior Filtration
The nano-silver air filter releases silver ions that eliminate airborne bacteria. The gold-fin evaporator coating prevents bacteria reproduction and spread.
Auto Restart
Restores to the last setting after a power failure.
Automatic Defrost
Standard on all models, featuring a crankcase heater and corner heater for optimal performance in cold weather.
Operating Temperature
Cooling: -22° to 122°F (-30° to 50°C), Heating: -22° to 75°F (-30° to 24°C).
Product Overview
Type: Single Zone Heat Pump
Voltage: 208-230V
Cooling Capacity Range: 6,000 to 24,000 BTUH
Refrigerant: [Refrigerant R454B]
Certifications: [AHRI Certified], [Energy Verified], [ETL Listed]
Visual Description: The document displays images of the indoor unit (wall-mounted, white, sleek design) and the outdoor unit (white, rectangular, with fan grille). It also shows certification logos.
Warranty Information
Warranty: 10 years on compressor, 10 years on parts. (Certain limitations apply; see printed warranty for details.)
Visit www.comfort-aire.com for more information.
Technical Specifications
Feature | ZHP06SA-1 | ZHP09SA-1 | ZHP12SA-1 | ZHP15SA-1 | ZHP18SA-1 | ZHP24SA-1 |
---|---|---|---|---|---|---|
Power Supply | 208/230V | 208/230V | 208/230V | 208/230V | 208/230V | 208/230V |
Cooling Capacity (BTUH) | 6,000 | 9,000 | 12,000 | 17,000 | 17,000 | 24,000 |
SEER2/EER2 | 35/17.4 | 33.3/17.0 | 29.4/14.2 | 25.6/15 | 25.6/15 | 25/13.1 |
HSPF2 | 30.0 | 22.0 | 14.5 | 16.2 | 16.2 | [To Be Determined] |
Cooling Amps | 2.1 | 3.1 | 3.7 | 5.5 | 5.5 | [To Be Determined] |
Dehumidification (pts/hr) | 1.06 | 1.06 | 1.06 | 2.32 | 2.32 | [To Be Determined] |
Heating Capacity (BTUH) | 9,000 | 12,000 | 12,000 | 20,000 | 20,000 | [To Be Determined] |
Heating Amps | 3.9 | 4.3 | 4.3 | 5.9 | 5.9 | [To Be Determined] |
INDOOR UNIT | ||||||
Airflow (CFM) | 153-424 | 153-424 | 153-424 | 318-618 | 318-618 | [To Be Determined] |
Fan Speeds (Cool/Heat/Vent) | 3 | 3 | 3 | 3 | 3 | 3 |
Sound Level (dBA) E-M-B | 19-42 | 19-42 | 19-42 | 16-44 | 16-44 | [To Be Determined] |
AIR DIRECTION | ||||||
Vertical Adjustment | Remote Control | Remote Control | Remote Control | Remote Control | Remote Control | Remote Control |
Auto Oscillation Up/Down | Standard | Standard | Standard | Standard | Standard | Standard |
INDICATOR LIGHTS | ||||||
Defrost | Standard | Standard | Standard | Standard | Standard | Standard |
Temperature Setting | 60°C (90°F) to 32°C (86°F) | |||||
INDOOR UNIT DIMENSIONS | ||||||
Width (inches) | 40.31 | 40.31 | 40.31 | 47.13 | 47.13 | [To Be Determined] |
Height (inches) | 12.64 | 12.64 | 12.64 | 14.61 | 14.61 | [To Be Determined] |
Depth (inches) | 9.69 | 9.69 | 9.69 | 11.02 | 11.02 | [To Be Determined] |
Net/Shipping Weight (lb) | 28.22/36.82 | 28.22/36.82 | 28.22/36.82 | 43.65/55.56 | 43.65/55.56 | [To Be Determined] |
OUTDOOR UNIT DIMENSIONS | ||||||
Width (inches) | 35.04 | 35.04 | 35.04 | 37.24 | 37.24 | [To Be Determined] |
Height (inches) | 26.50 | 26.50 | 26.50 | 31.89 | 31.89 | [To Be Determined] |
Depth (inches) | 13.46 | 13.46 | 13.46 | 16.14 | 16.14 | [To Be Determined] |
Net/Shipping Weight (lb) | 99.65/107.80 | 99.65/107.80 | 99.65/107.80 | 130.29/141.31 | 130.29/141.31 | [To Be Determined] |
OUTDOOR UNIT ELECTRICAL DATA | ||||||
Main Connection | Outdoor Unit | Outdoor Unit | Outdoor Unit | Outdoor Unit | Outdoor Unit | Outdoor Unit |
Min. Circuit Ampacity | 16 | 16 | 16 | 24.9 | 24.9 | [To Be Determined] |
Max Fuse/HACR | 20 | 20 | 20 | 25 | 25 | [To Be Determined] |
Recommended Int/Ext Connection Wire | 14 AWG/4 conductor THHN stranded/rated 600V | |||||
Line Set Size (inches) | ||||||
Liquid Line (OD) [in] | 1/4 | 1/4 | 1/4 | 3/8 | 3/8 | 3/8 |
Liquid Line (OD) [in] | 3/8 | 3/8 | 3/8 | 5/8 | 5/8 | 5/8 |
Max. Pre-set Conduit Length | 82 | 82 | 82 | 164 | 164 | 164 |
Max. Elevation (Outdoor) | 49 | 49 | 49 | 82 | 82 | 82 |
*Always comply with local and federal regulations and national electrical codes. 1 Min. 10 ft. line set recommended. 2 Oil traps must be installed every 16.5 to 23 ft. (5 to 7 m) when the outdoor unit is installed higher than the indoor unit.
Design data, specifications, and performance are subject to change without notice. *Final 15K & 24K specifications are pending.
This product complies with all California product labeling laws, including, but not limited to, the Safe Drinking Water and Toxic Enforcement Act of 1986, commonly known as Proposition 65.
Manufacturer Information
© 2025 MOTORS & ARMATURES, Inc.
MARS is a registered trademark of Motors & Armatures, Inc.
Comfort-Aire is a registered trademark of Motors & Armatures, Inc.
1900 Wellworth Ave., Jackson MI 49203 • 517.787.2100 • www.comfort-aire.com
Delivering Confidence
Related Documents
![]() |
Comfort-Aire ZHP Series Inverter Ductless Mini-Split Service Manual Comprehensive service manual for Comfort-Aire and Century ZHP Series Inverter Single Zone Ductless Mini-Split systems, covering safety, specifications, maintenance, and troubleshooting. |
![]() |
Manual de Instrucciones e Instalación Serie ZHP Comfort Aire Guía completa de instalación y manual de instrucciones para el aire acondicionado mini split sin conductos Comfort Aire Serie ZHP con tecnología inverter, incluyendo modelos ZHP15SA-1, ZHP18SA-1, ZHP24SA-1. Cubre seguridad, instalación, mantenimiento y solución de problemas. |
![]() |
Comfort-Aire CXP15**SA Series Horizontal Discharge Condensers Detailed specifications, features, and physical characteristics for Comfort-Aire's CXP15**SA Series horizontal discharge condensers, offering efficient cooling solutions from 1 to 5 Tons. |
![]() |
Comfort-Aire Serie UltraV: Aires Acondicionados Mini Split de Zona Única y Múltiple Descubra la serie Comfort-Aire UltraV de aires acondicionados mini split, que ofrecen calefacción y refrigeración eficientes con tecnología inverter. Diseñados para operación en climas fríos, con opciones de zona única y múltiple, y una amplia gama de capacidades para aplicaciones residenciales y comerciales. |
![]() |
Comfort-Aire CXP15**SA Series Horizontal Discharge Condensers - Specifications Comprehensive product data for the Comfort-Aire CXP15**SA Series horizontal discharge condensers, detailing features, technical specifications, performance metrics (SEER2, EER2), dimensions, sound levels, and model compatibility for HVAC applications. |
![]() |
Comfort-Aire VHP UltraV Series Mini-Split Systems: Specifications and Features Explore the Comfort-Aire VHP UltraV Series of single and multi-zone mini-split air conditioning and heating systems. This document details specifications, features, operating ranges, and model information for efficient year-round comfort. |
![]() |
Comfort-Aire VHP-DA Series Ducted Unit Installation Manual Comprehensive installation manual for the Comfort-Aire VHP-DA Series ducted air conditioning units. Covers safety precautions, product overview, installation procedures, refrigerant handling, wiring, testing, and troubleshooting. |
![]() |
Comfort-Aire Century VXP-SA Series Ultra High Efficiency Single Zone Heat Pump Manual de Instalación Este manual de instalación proporciona instrucciones detalladas para la serie Comfort-Aire Century VXP-SA de bombas de calor de zona única de alta eficiencia. Cubre la instalación, el cableado, las precauciones de seguridad y las especificaciones del producto para garantizar un funcionamiento seguro y eficiente. |