Instructions for AcuityBrands models including: WSX D Dimming Occupancy Wall Switch, WSX D, Dimming Occupancy Wall Switch, Occupancy Wall Switch, Wall Switch, Switch
WSX D - Dimming Occupancy Wall Switch
WSX Series - Wall Switch Sensor
File Info : application/pdf, 3 Pages, 1.11MB
DocumentDocumentCOVERAGE PATTERN · Small motion (e.g. hand movements) detection up to 20 ft (6.10 m), ~625 ft2 · Large motion (e.g. walking) detection greater than 36 ft (10.97 m), ~2025 ft2 · Wall-to-wall PIR coverage · Units with -PDT (Passive Dual Technology) option (also called MicrophonicsTM) provide overlapping detection of human activity over the complete PIR coverage area. Advanced filtering is utilized to prevent non-occupant noises from keeping the lights on. 6 Small motion detection to ~20 ft SIDE VIEW 1.2 m 4 ft 0m 3 6 0 ft 9 18 Small motion detection to ~20 ft 9 12 27 36 Large motion detection to >36 ft 3 12 0 m9 6 36 30 20 3 0 m 3 10 0 ft 10 Small motion ~40 ft coverage TOP VIEW INSTRUCTION SHEET WSX D 6 9 12 20 30 36 Dimming Occupancy Wall Switch CONVERSION FROM GROUND ONLY (NO NEUTRAL) TO NEUTRAL WIRING This product is pre-configured for wiring without a neutral with a solid ground; however, if connection to neutral is required by code, the unit easily converts in seconds. Step 1: Remove Yellow Label Step 2: Loosen Screws and Remove Metal Link Step 3: Connect Neutral to Silver Screw & Ground to Green Screw WIRING TO GROUND (NO NEUTRAL) WIRING TO NEUTRAL SPECIFICATIONS RIEFNMCEOOUVTNERNAMELCETTIANLGLTINOK VIO (+) PNK (-) GND H BLK BLK H DIMMING LOAD WIRE COLOR KEY 120/277 VAC WIRING } BLACK* - Line Input *BLACK wires BLACK* - Load Output can be reversed VIOLET -Low Voltage Dim Output (0-10 VDC) PINK -Low Voltage Common 347 VAC WIRING (-347 Option) Red wires replace Black wires. N H GND LOAD BLK BLK H VIO (+) PNK (-) DIMMING PHYSICAL SPECS SIZE: 2.74"H x 1.68"W x 1.63"D (6.96 cm x 4.27 cm x 4.14 cm) (not including ground strap) WEIGHT: 5 oz MOUNTING: Single Gang Switch Box MOUNTING HEIGHT: 30-48 in (76.2-121.9 cm) NOTE 1.) Do not wire device hot. 2.) Per NEC requirements, the 0-10V violet and pink wires must be installed as Class One. 3.) 0-10V Dimming Common from luminaire may be pink or as otherwise indicated per section 410.69 of the 2020 NEC. 4.) The 0-10V control wires must not exceed 250 ft (76 m) in length and must be sized at no less than 20 AWG. 5.) If no neutral is present, unit requires a solid ground connection in order to power up. TROUBLESHOOTING Unit does not appear to power up: · Confirm device is properly connected to neutral or ground, per the wiring diagram above. · Confirm all wiring connections and that 120/277VAC is present. ELECTRICAL SPECS MAXIMUM LOAD (Relay) 800 W @ 120 VAC / 1200 W @ 277 VAC / 1500 W @ 347 VAC MINIMUM LOAD: None MOTOR LOAD: 1/4 HP MAX SINK CURRENT: 50 mA 0-10V DIM MIN OUTPUT: <0.3 V FREQUENCY: 50/60 Hz (timers are 1.2x for 50 Hz) ENVIRONMENTAL SPECS OPERATING TEMP: 14° to 122° F (-10° to 50° C) RELATIVE HUMIDITY: 20 to 75% non-condensing ROHS COMPLIANT For further troubleshooting guidance, please contact the Controls Technical Support Team 1(800)-535-2465 Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com © 2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 10/22/2020 1 of 3 WSX D INSTRUCTION SHEET PAGE 2 ADAPTIVE DAYLIGHT HARVESTING (ADH) With Sensor Switch's Adaptive Daylight Harvesting (ADH), automatic dimming has never been more reliable - even in a wall switch. It works by establishing two state change set-points; daylight and darkness. The light level in the space will then be automatically maintained by intelligently controlling the dim level of the electric light source. Set-points can be established using the "Set Now" option or programmed using desired light levels as measured in foot candles (fc). DIMMING RANGE AMPLE DAYLIGHT DAYLIGHT SET-POINT DARKNESS SET-POINT NO DAYLIGHT / KEY LIGHTS FULLON LIGHTS FULLDIM PROGRAMMING INSTRUCTIONS Operational settings can be changed via the push-button sequence outlined below (note the example used is for changing occupancy time delay). 1. 5. While LED flashes back new setting 10x... e.g., 5 flashes confirms new 7.5 min time delay setting 2. 3. 4. e.g., press 2x for Fade Off Start Level Fade Rate Time Delay Occupancy Time On Mode Delay Switch On Rate Pred Grace 20x 21x 2x 3x Modes Darkness 19x 4x Set-Point 18x Pred Exit 17x 5x Daylight 6x Set-Point While LED flashes Low 16x Trim 15x PRESS BUTTON 7x Photocell Mode 8x High 14x 9x Trim Man 13x 12x 11x 10x On Grace Mic Min On Dim to Off Defaults Grace Dual LED Time Tech Operation back current setting 10x... e.g., 6 flashes is default 10 min time delay Test 30.0 min Mode 30 sec 27.5 min 25.0 min 14x 13x 1x 2x 12x 3x 11x 22.5 min 10x PRESS BUTTON 20.0 min 9x 8x 7x 4x 5x 6x 2.5 min 5.0 min 7.5 min 10.0 min 17.5 min 15.0 min 12.5 min e.g., press 5x to change to 7.5 min 6. Fade Off Start Level Time Delay On Mode Fade Rate Switch On Rate Pred Grace 20x 21x 2x 3x Modes Darkness 19x 4x Set-Point 18x 5x Pred Exit 17x Daylight 6x Set-Point 7. LED FLASHES Low 16x Trim 15x PRESS BUTTON 7x Photocell Mode 8x CONFIRMATION TWICE High Trim Man On Grace 14x 13x 12x Mic Grace Dual Tech 11x 10x LED Operation 9x Min On Time Dim to Off Defaults e.g., press 2x (for Occupancy Time Delay) to save and exit PROGRAMMING COMPLETE Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com © 2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 10/22/2020 2 of 3 WSX D INSTRUCTION SHEET OPERATIONAL SETTINGS PAGE 3 2 = Occupancy Time Delay The length of time an occupancy sensor will keep the lights on after it last detects occupancy. 1 - Test Mode** 5 - 7.5 min 9 - 17.5 min 13 - 27.5 min 2 - 30 sec 6 - 10.0 min* 10 - 20.0 min 14 - 30.0 min 3 - 2.5 min 4 - 5.0 min 7 - 12.5 min 8 - 15.0 min 11 - 22.5 min 12 - 25.0 min 6 = Daylight Set-Point The ambient light level at which the sensor sets the lights to the Low Trim setting. 1 - Set Now** 5 - 8 fc 9 - 48 fc 13 - 128 fc 2 - 0.1 fc 6 - 16 fc 10 - 64 fc* 14- 192 fc 3 - 1 fc 4 - 4 fc 7 - 24 fc 8 - 32 fc 11 - 80 fc 12 - 96 fc 15 - 256 fc **Test mode sets Occupancy Time Delay to 30 seconds, and increases photocell transition rate in addition to disabling the microphone on units with Dual Technology. 3 = On Mode Not applicable with Vacancy (VA) Option Automatic On Sensor automatically turns the lights on when it detects occupancy. Manual On Sensor requires pressing the button to turn the lights on. Reduced Turn-On Sensor is set to initially only detect large motions, effectively ignoring any reflected Passive Infrared (PIR) signals. Occupants will still be detected immediately when they enter the room as their PIR signal is large. Once lights are on, the sensor returns to maximum sensitivity. 1 - Automatic On* 3 - Reduced Turn-On 2 - Manual On 4 = Switch Modes Not applicable with Vacancy (VA) Option Switch Enable (Override Off) Button will turn lights off and keep them off until pressed again. The lights will remain off until the button is pressed again, restoring the sensor to Automatic On mode. Switch Disable User is prevented from turning off the lights via the push-button. Predictive Mode Pressing the push-button switch overrides the lights off and temporarily disables the occupancy detection. After 10 seconds, the occupancy detection reactivates and monitors for an additional 30 seconds. If no occupancy is detected during this period, the sensor will revert to Automatic On operation. If occupancy is detected, the sensor will remain in Override Off mode and requires the switch to be pressed again in order to restore the sensor to Automatic On. Predictive Mode with Expiration Pressing the push-button switch overrides the lights off and temporarily disables the occupancy detection. After 10 seconds, the occupancy detection reactivates and monitors for an additional 30 seconds. If no occupancy is detected during this period, the sensor will revert to Automatic On operation. 1 - Switch Enable 3 - Predictive Mode 2 - Switch Disable 4 - Predictive Mode with Expiration* **Set Now will automatically select the Daylight Set-Point based on the current conditions in the room. Lights will go to full dim and sensor will rapid flash for 15 seconds allowing occupant to move out of direct view of sensor. Once the set-point selection is completed, the sensor will double-blink in confirmation. 7 = Photocell Mode Inhibit Only Prevents lights from automatically coming on when light level is above the Inhibit Set-Point Adaptive Daylight Harvesting Dims lights from high trim to low trim setting according to Darkness and Daylight set-points. 1 - Disabled* 3 - Adaptive Daylight Harvesting 2 - Inhibit Only 8 = Dim to Off Occupancy Time Delay After the Occupancy Time Delay (Function 2) has expired, this setting specifies the amount of time lights are held at Low Trim (Function 16) before turning off. 1 - 0 sec* 5 - 7.5 min 9 - 17.5 min 2 - 30 sec 6 - 10 min 10 - 20 min 3 - 2.5 min 7 - 12.5 min 11 - Stays at dim (never off) 4 - 5 min 8 - 15 min 9 = Restore Defaults Returns all functions to original settings. 1 - Maintain Current* 2 - Restore Defaults 10 = Minimum On Time Required initial time for lamps to be on after each switch on, regardless of occupancy status. Once met, lights resume following occupancy time delay. 1 - 0 min (disabled)* 4 - 45 min 2 - 15 min 5 - 60 min 3 - 30 min 5 = Darkness Set-Point / Inhibit Set-Point The ambient light level at which the sensor sets the lights to the High Trim setting. 1 - Set Now** 5 - 8 fc 9 - 48 fc 13 - 128 fc 2 - 0.1 fc 6 - 16 fc 10 - 64 fc 14- 192 fc 3 - 1 fc 7 - 24 fc* 11 - 80 fc 15 - 256 fc 4 - 4 fc 8 - 32 fc 12 - 96 fc **Set Now will automatically select the Darkness Set-Point based on the current conditions in the room. Lights will go to full bright and sensor will rapid flash for 15 seconds allowing occupant to move out of direct view of sensor. Once the set-point selection is completed, the sensor will double-blink in confirmation. 11 = LED Operation Indicates behavior of device's LED. 1 - Occupancy Indication* 2 - Disabled 12 = Dual Technology (MicrophonicsTM) The secondary method of occupancy detection that allows the sensor to hear occupants. 1 - Normal* 4 - Low 2 - Off 5 - Phase Off (15-10-5 min) 3 - Medium 13 = Microphone Grace Period Time period after lights are automatically turned off that they can be voice reactivated. 1 - 0 sec 5 - 40 sec 2 - 10 sec* 6 - 50 sec 3 - 20 sec 7 - 60 sec 4 - 30 sec 14 = Manual On Grace Period Time period after lights automatically turn off that they can be reactivated by motion. Applicable only when sensor is in Manual On (Semi Auto) mode. 1 - 0 sec 3 - 15 sec* 15 = Dimming Range Max (High Trim) The maximum output level of the sensor. 1 - 0 VDC 5 - 3 VDC 9 - 7 VDC 13 - 10 VDC* 2 - 1 VDC 6 - 4 VDC 10 - 8 VDC 3 - 1.5 VDC 7 - 5 VDC 11 - 9 VDC 4 - 2 VDC 8 - 6 VDC 12 - 9.1 VDC** **Default for EZ option 16 = Dimming Range Min (Low Trim) The minimum output level of the sensor. 1 - 0 VDC 5 - 3 VDC 9 - 7 VDC 2 - 1 VDC* 6 - 4 VDC 10 - 8 VDC 3 - 1.5 VDC** 7 - 5 VDC 11 - 9 VDC 4 - 2 VDC 8 - 6 VDC 12 - 9.1 VDC 13 - 10 VDC **Default for EZ option 17 = Predictive Exit Time Time period after manually switching lights off for occupant to leave the space. Applicable only when sensor is in Predictive Off mode. 1 - 5 sec 4 - 8 sec 7 - 15 sec 2 - 6 sec 5 - 9 sec 8 - 20 sec 3 - 7 sec 6 - 10 sec* 9 - 30 sec 18 = Predictive Grace Time Time period after Predictive Exit Time that sensor rescans the room for remaining occupants. Applicable only when sensor is in Predictive Off mode. 1 - 0 sec 4 - 20 sec 7 - 50 sec 2 - 5 sec 5 - 30 sec* 8 - 60 sec 3 - 10 sec 6 - 40 sec 19 = Fade On Rate Time required for light to reach preset level. 1 - 0.75 sec* 3 - 5 sec 2 - 2.5 sec 4 - 15 sec 20 = Fade Off Rate Time required for light to turn Off. 1 - 0.75 sec 3 - 5 sec 2 - 2.5 sec* 4 - 15 sec 21 = Start Level Level of light output when occupancy is initially detected. Not applicable in Automatic Dimming Control (ADH) mode. 1 - 10% 4 - 40% 7 - 70% 10 - 100%* 2 - 20% 5 - 50% 8 - 80% 5-year limited warranty. Full warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Specifications subject to change without notice. Actual performance may differ as a result of end-user environment and application. 3 - 30% 6 - 60% 9 - 90% * DEFAULT SETTING Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com © 2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 10/22/2020 3 of 3