User Manual for invt models including: IVDM-20, IVDM-20 DC Voltage Detection Module, DC Voltage Detection Module, Voltage Detection Module, Detection Module, Module

邱祥龙

IVDM-20 DC Voltage Detection Module User Manual

1 day ago — This manual describes the product overview, installation, wiring, and commissioning instructions. Before installing the VFD, read this manual carefully to ...

PDF preview unavailable. Download the PDF instead.

IVDM-20 DC Voltage Detection Module User Manual V1.0
IVDM-20 DC Voltage Detection Module
IVDM-20 DC Voltage Detection Module User Manual

Preface
Thank you for choosing INVT IVDM-20 DC voltage detection module. IVDM-20 DC voltage detection module is mainly used in DC-DC bidirectional DC power supply products to detect the input and output voltage and current of the system. It needs to be used with the GD880 series VFD control box. The module transmits the detection signal to the control box through optical fibers, achieving monitoring of system voltage and current. This manual describes the product overview, installation, wiring, and commissioning instructions. Before installing the VFD, read this manual carefully to ensure the proper installation and running with the excellent performance and powerful functions into full play. Product features:  Supports one DC voltage detection of 0­1000VDC  Supports two voltage type open-loop Hall current detection  Adopts optical-fiber communication, enabling fast and stable communication rate  Supports rear mounting method, facilitating dismounting and mounting
1 Product overview
1.1 Model description
Figure 1-1 Product nameplate and model designation

Nameplate

Product model Rated input
Manufacture No.

MODEL: INPUT: S/N:

IVDM-20 DC24V 0.5A XXXXXXXXXXXXXXX

Product model

IVDM - 20
10: AC voltage detection 20: DC voltage detection
IVDM: Synchronous voltage detection module

IVDM-20 DC Voltage Detection Module

1.2 Specifications

Table 1-1 Specifications

Parameters Working temperature Storage temperature
Relative humidity Running environment Installation method
IP rating Heat dissipation method

Specification -10­+50ºC -10­+60ºC 5%­95% (No condensation) No corrosive gas Rear mounting method IP20 Natural air cooling

1.3 Technical parameters

Table 1-2 Technical parameters

Parameters

Specification

Supply voltage/current

24V±5%/0.5A

Communication connection mode Voltage detection Current sampling

Optical-fiber communication 0­1000VDC Two voltage type open-loop Hall current sensor

1.4 Structure

Figure 1-2 Structure diagram PE
X5

X4

X3 X2 X2

X1

Table 1-3 Component description

No.

Name

Description

X1-DC voltage Input voltage range: 0­1000VDC 1 detection terminal Cable cross-sectional area: 0.5­2.5mm2

Current detection Hall component wiring terminal A

X2-Current detection Cable cross-sectional area: 0.5­2.5mm2

2

terminal A

Use shielded four-core twisted-pair cable with both ends

grounded. The total length of the cable is less than 1.5m.

Current detection Hall component wiring terminal B

X2-Current detection Cable cross-sectional area: 0.5­2.5mm2

3

terminal B

Use shielded four-core twisted-pair cable with both ends

grounded. The total length of the cable is less than 1.5m.

PWR power supply status indicator

Red LED ON: Power supply is connected.

Red LED OFF: The module is not powered on or the power

4 X3-Status indicator supply is abnormal.

ONLINE operation status indicator

Red LED flashes: The communication is normal.

Red LED OFF: Operation exception.

Externally powered: 24VDC±5%/200mA

X4-24VDC power

5

Two-core twisted-pair cable is recommended.

input terminal

Cable cross-sectional area: 0.5­2.5mm2

The expansion module communicates with the control box

X5-Optical fiber

6

through optical fiber.

connection terminal

Plastic optical fiber

2 Installation and wiring

IVDM-20 DC Voltage Detection Module

2.1 Installation precautions

Make sure the device have been powered off before installation.

Note

 Prevent the module from falling or shock to avoid damage.  Do not disassemble the module to avoid damage.  Please tighten the screws according to the required torque to avoid
damage or looseness.

 Required tools: Phillips screwdriver PH1, straight screwdriver SL3

Table 2-1 Screw torque requirements

Screw size M3 M4

Fastening torque 0.55 N·m 1.2 N·m

2.2 Dimensions
The dimensions of the DC voltage detection module is 37.4x113x180 mm (W*D*H), as shown in Figure 2-1.
Figure 2-1 Product outline and mounting dimensions diagram (unit: mm)

Ø5

37.4 180 170

113 138.9

ON-LINE

PRW

+15V -15V GND 1A

+15V -15V GND 1B

DC-

DC+

Ø5

5

17.5

2.3 Installation instructions
The rear mounting method is used. Align the installation holes and tighten the screws. Figure 2-2 Installation diagram

Note:
 Ensure that all terminals and fiber optic plugs are installed in place for effective electrical connection.
 The module is grounded through contact between its exposed metal shell and the assembly board inside the cabinet, so the assembly board must be an exposed metal plate. To ensure the reliable operation of the module and meet the EMC requirements, please tighten the screws to ensure reliable grounding.

IVDM-20 DC Voltage Detection Module
2.4 Disassembly instructions
Step 1 Disconnect the power supply and disassemble all cables connected to the expansion module. Step 2 Use a Phillips screwdriver to remove the grounding screw of the module. Step 3 Pull the module out to a suitable position.
2.5 User's wiring terminal
Figure 2-3 IVDM-20 appearance diagram

TXD RXD

ON-LINE

PRW

+15V -15V GND 1A

24V COM

+15V -15V GND 1B

DC-

DC+

Table 2-2 X1 terminal function definition

X1 terminal definition
DC+ DC-

Terminal name
Voltage input+ Voltage input-

Specifications Input voltage range: 0­1000VDC

Note: The positive and negative DC voltage wiring on the IVDM-20 must match the positive and negative poles of DC-DC output wires.

Table 2-3 X2 terminal function definition

X2 terminal definition
+15V -15V GND
IA/IB

Terminal name
+15VDC voltage -15VDC voltage Power ground Hall current detection input terminal

Specifications Power output Detects the current input

X3 terminal definition
PWR
ONLINE

Table 2-4 X3 terminal function definition

Terminal name Power supply status
indicator
State indicator

Specifications
Red LED ON: Power supply is connected. Red LED OFF: The module is not powered on or the power supply is abnormal Red LED flashes: The communication is normal. Red LED OFF: Operation exception.

X4 terminal definition
24V COM

Table 2-5 X4 terminal function definition

Terminal name
24VDC power supply Power ground

Specifications Externally powered: 24VDC±5%/0.5A

X5 terminal definition
RXD
TXD

Table 2-6 X5 terminal function definition

Terminal name
Receiving optical fiber Transmitting optical
fiber

Specifications Plastic optical fiber

The IVDM-20 DC voltage detection module is connected to the fiber optic expansion module EC-TX821/TX823 through optical fibers, transmitting the detection signal to the control box. Figure 2-4 shows the external wiring diagram of the IVDM-20 module, taking the fiber optic expansion module EC-TX823 as an example:

IVDM-20 DC Voltage Detection Module Figure 2-4 External wiring diagram when using IVDM-20
Control box

Optical fiber expansion module
STATUS FAULT

VT1 VR1

VT2 VR2 VT3 VR3

TXD RXD
+15V -15V GND
IA +15V -15V GND
IB DC+
DC-

24V COM

24V COM
HALL HALL DC+ DC-

2.6 Wiring precautions
 It is recommended to place the fiber optic expansion module EC-TX821/TX823 at expansion slot 2 and slot 3 of the control box.
 Handle the optical fibers with care to prevent the fiber optic cable and connector damage, and keep the connector clean.
 Ensure that the direction of the connector is correct when installing. Align and insert the connector into the interface until the "click" sound is heard, indicating it has been installed.
 When disassembling, grip the connector tightly and pull it out. Do not directly pull the optical fiber cable.
3 Commissioning instruction
Figure 3-1 IVDM-20 configuration flowchart
Start
Check the electrical connection is proper.
Power on the control box and the IVDM-20 module
(PWR indicator is ON)
Set the parameter P54.00 to 1.

Check the parameter

N

P54.01 to confirm whether

the module status is 1:

Online.

Y

End

Table 3-1 Function code parameters related to IVDM-20

Function code

Name

Description

0: One-expand-three expansion

P54.00 Module type modules

1: DC/AC voltage sampling card

P54.01

Module online status

Bit0­Bit5

Online status of modules in expansion slots (0: Offline 1: Online)

Setting range
0­1
0­1

Default 1 0

Note: For other parameter settings of the IVDM-20 DC voltage detection module, see software manuals of the GD880 series rectifier unit.

66001- 01217

IVDM-20 DC Voltage Detection Module 202310 (V1.0)


Microsoft Word 2010 Microsoft Word 2010