Hörmann RSZ1 Hand Transmitter Operating Instructions
1 Intended Use
This hand transmitter is intended for actuating door operators and accessories, provided they are equipped with receivers from Hörmann KG.
2 Safety Instructions
WARNING: Danger of injury during door travel
Persons may be injured by door travel if the hand transmitter is actuated. Ensure that hand transmitters are kept away from children and are only used by people who have been instructed on how the remote-controlled door functions. If the door has only one safety feature, only operate the hand transmitter when you are within sight of the door. Only drive or pass through remote-controlled door systems if the door is in the OPEN end-of-travel position.
CAUTION: Uncontrolled door travel
During the learning process, activation of the teaching transmitter can initiate door travel if a receiver programmed for it is located nearby. Please ensure that no persons or objects are within the danger area of the door during the learning process.
ATTENTION: Functional disturbances caused by environmental conditions
These conditions can impair function. Protect the hand transmitter from the following conditions: moisture, dust, and direct exposure to the sun (permissible ambient temperature: -20°C to +60°C).
NOTE: Local conditions may affect the range of the radio system.
3 Description of the Hand Transmitter
Refer to Figure 1:
- (a) LED
- (b) Hand transmitter button
- (c) Hand transmitter bottom part
- (d) Battery CR2025
- (e) Hand transmitter top part
The LED (a) signals each push of the button on the hand transmitter (see Fig. 1):
- The LED is lit: The hand transmitter is transmitting.
- The LED flashes: Transmission is still taking place, but the battery is almost discharged. Exchange the battery soon.
- No LED response: Check whether the battery has been inserted correctly (see Fig. 2). If necessary, exchange the battery for a new one.
4 Inserting or Exchanging the Battery
Refer to Figure 2. Use only the battery type CR2025. Pay attention to the correct polarity.
5 Teaching in the Hand Transmitter on the Operator/Receiver
The hand transmitter works with a rolling code that changes with each sending procedure. For this reason, the hand transmitter must be taught in with the desired hand transmitter button on each receiver that is to be controlled.
- To do this, briefly press the P button on the operator cover or the P button on the receiver (see Fig. 3). The red LED will begin to flash, signaling that the desired hand transmitter button can be taught in.
- Press and hold the hand transmitter button until the red LED flashes quickly; then release the hand transmitter button.
- Press the hand transmitter button again within 15 seconds, until the red LED begins flashing very rapidly; then release the hand transmitter button. Once the rapid flashing ends, the desired hand transmitter button has been successfully taught in and the red LED will remain lit.
- After teaching in the hand transmitter or extending the radio system, check the functions.
6 EU Declaration of Conformity
Manufacturer: Hörmann KG Verkaufsgesellschaft, Upheider Weg 94-98, D-33803 Steinhagen
The manufacturer herewith declares under their sole responsibility that the product:
- Equipment/System: Hand transmitter
- Model: RSZ1-433
- Intended Use: Actuating of door and their accessories
- Transmission Frequency: 433.9 MHz
- Radiant Power: max. 10 mW (EIRP)
conforms to the respective essential requirements of the directives listed below with intended use, on the basis of its style and type in the version marketed by us:
- 2014/53/EU (RED): EU Directive for Radio Equipment
- 2011/65/EU (RoHS): Restriction of the use of certain hazardous substances
Applied Standards and Specifications:
- EN 62368-1:2014 + AC:2015: Product safety (Article 3.1(a) of 2014/53/EU)
- EN 62479:2010: Health (Article 3.1(a) of 2014/53/EU) (According to section 4.2 the product automatically complies with this standard, as the radiant power (EIRP), tested according to ETSI EN 300220-1, is lower than the low power exclusion level Pmax of 20 mW)
- EN 50581:2012: Restriction of the use of certain hazardous substances
- ETSI EN 301489-1 V2.2.0
- ETSI EN 301489-3 V2.1.1: Electromagnetic compatibility (Article 3.1(b) of 2014/53/EU)
- ETSI EN 300220-1 V3.1.1
- ETSI EN 300220-2 V3.1.1: Efficient use of the radio spectrum (Article 3.2 of 2014/53/EU)
Any modifications made to the product without our approval will invalidate this declaration.
Steinhagen, Germany, 13.06.2017
ppa. Axel Becker, Management