User Manual for LSC models including: PowerPoint Power Distribution System, PowerPoint, Power Distribution System, Distribution System
Power Point User Manual Page 2 Disclaimer LSC Control Systems Pty Ltd has a corporate policy of continuous improvement, covering areas such as product design and documentation.
POWERPOINT - LSC
File Info : application/pdf, 9 Pages, 661.08KB
DocumentDocumentPower Point Power Distribution System User Manual LSC Control Systems © +61 3 9702 8000 info@lsccontrol.com.au www.lsccontrol.com.au Version 1.3 March 2023 Power Point User Manual Disclaimer LSC Control Systems Pty Ltd has a corporate policy of continuous improvement, covering areas such as product design and documentation. To achieve this goal, we undertake to release software updates for all products on a regular basis. In light of this policy, some detail contained in this manual may not match the exact operation of your product. Information contained in this manual is subject to change without notice. In any event, LSC Control Systems Pty Ltd cannot be held liable for any direct, indirect, special, incidental, or consequential damages or loss whatsoever (including, without limitation, damages for loss of profits, business interruption, or other pecuniary loss) arising out of the use or the inability to use this product for its intended purpose as expressed by the manufacturer and in conjunction with this manual. Servicing of this product is recommended to be carried out by LSC Control Systems Pty Ltd or its authorised service agents. No liability will be accepted whatsoever for any loss or damage caused by service, maintenance or repair by unauthorised personnel. In addition, servicing by unauthorised personnel may void your warranty. LSC Control Systems' products must only be used for the purpose for which they were intended. Whilst every care is taken in the preparation of this manual, LSC Control Systems takes no responsibility for any errors or omissions. Copyright Notices "LSC Control Systems" is a registered trademark. lsccontrol.com.au is owned and operated by LSC Control Systems Pty Ltd. All Trademarks referred to in this manual are the registered names of their respective owners. All rights reserved. Contact Details LSC Control Systems Pty Ltd ABN 21 090 801 675 65-67 Discovery Road Dandenong South, Victoria 3175 Australia Tel: +61 3 9702 8000 email: info@lsccontrol.com.au web: www.lsccontrol.com.au Page 2 Power Point User Manual Contents 1 Introduction ................................................................................................2 1.1 Overview .................................................................................................................... 2 1.2 Features ..................................................................................................................... 2 2 Front Panel .................................................................................................2 3 Setting Up and Connecting ........................................................................3 3.1 Safety ......................................................................................................................... 3 3.2 Unpacking .................................................................................................................. 3 3.3 Mounting..................................................................................................................... 3 3.4 Connections ............................................................................................................... 3 3.4.1 Input Power Supply ............................................................................................. 3 3.4.2 Outputs and Phasing ........................................................................................... 3 4 Troubleshooting .........................................................................................3 4.1 Maintenance...............................................................................................................3 4.2 Tripped Breakers ........................................................................................................ 3 5 Specifications and Output Options ............................................................4 5.2 Wieland Pinouts..........................................................................................................6 5.3 Socapex Pinouts.........................................................................................................6 6 Compliance Statements .............................................................................7 Page 3 Power Point User Manual 1 Introduction 1.1 Overview PowerPoint is a simple to use power distribution unit with a 3 phase mains input (single phase input available) and either 6 or 12 single phase outputs depending upon the model. Designed for applications wherever fixed or mobile power distribution is required, the PowerPoint distribution rack offers a 4-pole mains input isolator switch with Neutral Disconnect as standard and individual RCBO (RCD+MCB) per output channel. There are also 3 neon phase indicators to show power input to the rack. Output circuit rating can be specified as either 10A, 16A or 25 Amps and back panel options include either Australian GPO, Socapex, PowerCon or Hard Wired Terminals, depending upon the model. 1.2 Features The PowerPoint Feature list includes: · A front panel mounted 4-pole mains input isolator switch with neutral disconnect as standard provides easy access for quick isolation for the PowerPoint · Three neon indicators show state of input phase power. Easily visible from a distance · Twelve 10A, twelve 16A or six 25A output circuits · Residual Current circuit Breaker with Overcurrent protection (RCBO) devices for each output circuit are used to combine protection against current overload and short circuits and protection against earth leakage currents. Essentially, they protect connected loads and prevent users from receiving a life threatening shock. Standard on all LSC power products · The PowerPoint is at home as a 19" rackmount module in portable flight cases or touring frames or permanently installed in equipment racks. Versatility plus for any situation! · Three phase operation · Single phase operation possible · Utilising the same proven mechanical chassis as LSC's premier products such as the APS power distribution unit, GEN VI and RED3 dimmers, the PowerPoint is built to the same exacting standards ensuring great consistent performance when you need it, time after time. 2 Front Panel Output Load RCBO's Main Input Isolator Input phase labels 12 channel PowerPoint See section 4 for rear panel options. Input phase presence indicators Page 2 Power Point User Manual 3 Setting Up and Connecting 3.1 Safety All electrical work must be carried out by suitably qualified persons. 3.2 Unpacking Your PowerPoint is fully tested and inspected before leaving the factory. Upon delivery, inspect the PowerPoint for signs of damage. In the event of any damage, contact your LSC agent. 3.3 Mounting The PowerPoint is designed for mounting in a standard 19 inch rack. It occupies 3RU (Rack Units) of space. 3.4 Connections 3.4.1 Input Power Supply Always ensure that the Input Isolator is in the OFF position before connecting or disconnecting the input power. PowerPoint must be fed from a suitable external circuit breaker. The nominal input voltage is 220-240 Volts. 3-phase Star (380-415V). 50-60Hz. Single phase operation is possible but input current must be limited to 63A in total. 3.4.2 Outputs and Phasing Always ensure that the Output Load RCBO's are in the OFF position before connecting or disconnecting any loads. The individual outputs are fed from the following input power phases. This input phase numbering is also shown on the front panel below each output circuit breaker. Input Phase 1 2 3 1 2 3 Output 1 2 3 4 5 6 Input Phase 1 2 3 1 2 3 Output 7 8 9 10 11 12 4 Troubleshooting Warning. No user controls or user serviceable parts are located inside the PowerPoint. Refer all servicing to suitably qualified personnel. 4.1 Maintenance Check that all connector screw terminals (if fitted) are tight. This must be performed by a suitably qualified person. 4.2 Tripped Breakers If a channel is not working check the RCBO (Residual Current circuit Breaker with Over current protection) for that channel. If the RCBO has tripped (OFF), firstly try to determine the cause of the breaker tripping. It could be a blown lamp or a circuit overload or a earth leakage fault. Rectify to problem (replace the lamp or reduce the load) then restore the RCBO by pushing it all the way down then lifting it up. If the RCBO continues to trip, refer the problem to a suitably qualified person. Page 3 Power Point User Manual 5 Specifications and Output Options Model Protection Power 12 x 10A 12 x 16A 6 x 25A 10A Residual Current Breaker (RCBO) per output channel 16A Residual Current Breaker (RCBO) per output channel 25A Residual Current Breaker (RCBO) per output channel 30mA Earth leakage trip current per channel Front panel mounted neon power indicator per phase Mains power input protected by 4-pole mains isolator switch with neutral disconnect * PWP12/16/32A model supplied with 3phase 32A MCB in lieu of 4-pole mains isolator * PWP12/16/40A model supplied with 3phase 40A MCB in lieu of 4-pole mains isolator Nominal 100-240V AC 3-phase star TN-S with fully rated earth, 50-60Hz Operating range typically 90-260V AC 45-65Hz Auto voltage and frequency adjustment Hardwired models supplied with rear panel mounted 5 cage clamp style terminals Supplied with 1.2m long H07 rubber 5 core x 6mm² cable with 32A 5-pin 3-phase plug fitted (export models supplied with no plug) Supplied with 1.2m long H07 rubber 5 core x 10mm² cable no connector supplied (export models supplied with no plug) Supplied with 1.2m long H07 rubber 5 core x 6mm² cable with 40A 5-pin 3-phase plug fitted (export models supplied with no plug) Mechanicals Peace of mind *PWP12/16/32A model supplied with 3-phase 1.2m H07 5 core x 6mm² rubber cable fitted with 32A 3-phase plug. *PWP12/16/40A model supplied with 3-phase 1.2m H07 5 core x 6mm² rubber cable fitted with 40A 3-phase plug 483mm (w) x 132mm (h) x 300mm (d) 3RU x 19" rackmount Weight: 11kg Corrosion-resistant, powder-coated steel chassis with rear-screened polycarbonate labels CE (European) and RCM (Australian) approved, two-year warranty, designed and manufactured in Australia by LSC, an Australian owned company with over 40 years' experience in developing world first products Page 4 Power Point Outputs PWP12/10A PWP12/16A/32 User Manual PWP6/25A 12 x 3-pin 10 Amp Australian sockets PWP12/10T 12 x 3-pin 20 Amp Australian sockets. 32A MCB (Main Circuit Breaker) PWP12/16A/40 6 paired 3-pin 20Amp/15Amp Australian sockets PWP6/25T 12Ch x 10A Hardwired terminals PWP12/10W 12 x 3-pin 20 Amp Australian sockets. 40A MCB (Main Circuit Breaker) 6Ch x 25A Hardwired terminals 2 x 16-pin Wieland sockets PWP12/10X. 2 x 19-pin Socapex sockets PWP12/10P 12 x PowerCON sockets Page 5 Power Point 5.2 Wieland Pinouts User Manual WARNING. Several wiring standards exist for the pin outs of Wieland multipin sockets. If in doubt, a suitably qualified person should check that your Wieland cables are wired to the same standard as your Powerpoint.. Note: Earth connection is via the clips on the side of the socket insert. 5.3 Socapex Pinouts Connector #1 Function Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 Pin 15 Pin 16 Pin 17 Pin 18 Pin 19 Chan 1 Active Chan 1 Neutral Chan 2 Active Chan 2 Neutral Chan 3 Active Chan 3 Neutral Chan 4 Active Chan 4 Neutral Chan 5 Active Chan 5 Neutral Chan 6 Active Chan 6 Neutral Earth Earth Earth Earth Earth Earth Earth Connector #2 Function Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 Pin 15 Pin 16 Pin 17 Pin 18 Pin 19 Chan 7 Active Chan 7 Neutral Chan 8 Active Chan 8 Neutral Chan 9 Active Chan 9 Neutral Chan 10 Active Chan 10 Neutral Chan 11 Active Chan 11 Neutral Chan 12 Active Chan 12 Neutral Earth Earth Earth Earth Earth Earth Earth Page 6 Power Point User Manual 6 Compliance Statements The Power Point from LSC Control Systems Pty Ltd meets all required CE (European), RCM (Australian) and UKCA (United Kingdom) standards. CENELEC (European Committee for Electrotechnical Standardization). Australian RCM (Regulatory Compliance Mark). UK Conformity Assessed. WEEE (Waste Electrical and Electronic Equipment). The WEEE symbol indicates that the product should not be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recycling. For more information about how to recycle your LSC product, contact the dealer where you purchased the product or contact LSC via email at info@lsccontrol.com.au You can also take any old electrical equipment to participating civic amenity sites (often known as `household waste recycling centres') run by local councils. You can locate your closest participating recycling centre using the following links. · AUSTRALIA http://www.dropzone.org.au. · NEW ZEALAND http://ewaste.org.nz/welcome/main · NORTH AMERICA http://1800recycling.com · UK www.recycle-more.co.uk. -END- Page 7