User Manual for celsicom models including: MM611, Moisture Measurement, Measurement, Moisture Measurement in Wood, MM611 Moisture Measurement in Wood, Measurement in Wood

Support - Celsiview


File Info : application/pdf, 4 Pages, 331.04KB

PDF preview unavailable. Download the PDF instead.

MM611 EN
User manual MM611
Quick Guide
Register as a customer and create an account for the Celsiview cloud service
At the moment the Celsiview cloud service version two can be tested, it can be accessed by clicking on the "Celsiview 2 Beta" button on celsiview.se. The instructions below are based on Celsiview 2.
Click on the "Create new account" button. Fill in all the information needed to create the account. A verification email will then be sent to the email address provided in the registration process. Click on the link in the email to verify the account. If you do not receive an email, please check the spam mail. Once the account is verified, a page will appear with a link to the login page.
Adding the sensor to your sensor register
Go to the Celsiview 2 login page by clicking on "Celsiview 2 Beta" on celsiview.se and log in. Select " Sensor " in the menu and then " Add new sensor ". Now scan a sensor or enter the data manually (S/N + control code written on the sensor). After the sensor data is displayed, click on "Add this sensor". The cost of the sensor is now presented. Accept by adding the sensor to the shopping basket. Now scan the remaining sensors in the same way before proceeding to checkout.
Click on the shopping basket and view the contents. A summary of the costs is now displayed. Select or create an invoice recipient. The invoice recipient should contain all the information needed to be accepted by your finance department. The references, cost centre, etc. will appear on your invoice. Click on "Complete transaction" to activate the sensor.
Start and activate the sensor(s)
Hold the grey sensor in both hands, place your right and left thumbs on top of the °celsicom logo on the top of the sensor. Now slide the lid upwards/forwards to open it.
Insert 2 alkaline AA/LR6 batteries (1.5V) into the battery holder. The sensor will now beep to indicate that it is booting up and the orange LED will light up. Both orange and green LEDs will light up shortly afterwards in a constant light while the sensor is searching for a mobile connection. The connection to the mobile network may take several minutes. When the sensor is properly connected, the orange LED goes out and the green one starts flashing and three short beeps are heard. The green LED now flashes the mobile signal strength every 30 seconds for three minutes. 3 blink=high level, 2=medium and 1=low. Feel free to move the transducer to achieve the best possible strength. A better signal strength gives a longer battery life.
After three minutes, the sensor switches to measuring/logging once every hour and transmitting

all logged data every three hours to save battery power. Measurement and transmission intervals are
adjustable in the Celsiview cloud service. Measuring more often than once every hour will affect the properties of the wood material (measurement object) and may result in inaccurate readings. To restart the above process or if the sensor does not connect properly, disconnect one battery, wait 60 seconds and reconnect it again. (or press the Reset-switch if there is one on the circuit board)

Add/change measurement locations linked to the sensor

Login to celsiview.se (Version 2 Beta).

Click on "Sensors" in the menu. At the far right of the line for the sensor, some symbols are displayed.

To add a measuring location (value) click on the plus sign and enter a name/prefix for the readings,

e.g. "Moisture content level". Press "OK". The location is now created and can be found under the menu

item "Locations".

Add a measuring location (value)

To change a setting/name of a location, e.g. set the measurement curve (fur/spruce/Protimeter WME), click on "Locations" in the menu and then on the tool
symbol on the right of the line or click on a line and
select "Go to settings".

By clicking on the star symbol on the far right of a location row, or selecting "Make a favorite" after clicking on a row, that measurement will appear as a favorite (widget) on the home screen. (Menu item "Home")
The options "Settings", "Reports" and "Make a favourite" etc. are also accessible by simply clicking on any row/location on the "Locations" page.

Reports
To print or export reports/measurements, click on "Reports" in the menu. Select what to display in the report/graph by the menu options above the graph. It also selects the time period you want to look at. Click on the "Export" button to download or send the report as e.g. an Excel file or PDF.
My business
In the "My business" menu, sites can be structured into different groups/folders. Right-click on "Groups and locations" to create a group/folder. Then drag and drop the measurement locations you want into any group.
A group or location can also be shared with another person by right-clicking on the location or group and selecting "Share". Select "Create new user", enter the email address of the person to be assigned to the site/group. Automatically, the username of that person will be set to the same as the email address. Click on "OK". The new recipient now appears in the list of selectable recipients. Select the rights the new user should have. Click on "OK". The new user will now receive an e-mail asking him to choose a password. The new user can then log in with their details and will have access to what has been distributed.

Add alarm recipients
Log in to the account. Click on "Administration" > "Alarm recipients". in the left hand menu. Add the required information of the alarm recipient using the button (+ Add new alarm recipient). Test the alarm by clicking on the mail box symbol of the recipient to which the test should be sent. NOTE! Check that it arrives.
Other information
Stainless steel screws work well as measuring points in the measurement object (wooden structure). Pins/nails may drop out of the material as it dries.
Avoid interference with the measurement signal by following these points:
· The MM611 bus cable and measuring cables should be placed at least 1 meter away from electrical equipment or cables · The measuring cables are sensitive to ESD/static electricity. Take measures to protect them · A jagged/uneven waveform in a report indicates interference at the measurement point
The sensor should be mounted with the three half-rings on the cover facing upwards. If the sensor is to be mounted against a metal surface, magnetic mount 7040 0060 (or other non-metallic spacer) must be used to bring the sensor out at least 10 mm from the mounting surface. Otherwise, the metal surface will interfere with the connection of the sensor and the measurement data will have difficulty reaching our servers.
Support
All support is handled by our distributors. See celsicom.se for more information. User manuals and other support material are available at support.celsicom.se.

User manual MM611

Model

Measured value

Range

MM600P1

Temperature Resistance (normal) Resistance (max) Moisture ratio Fur Wood Trätek (normal) Moisture ratio Fur Wood Trätek (max) Protimeter WME A (normal) Protimeter WME A (max)

-30°C to +70°C 200kOhm to800MOhm 50kOhm to 1GOhm 12% to 26% 11,5% to 45% 10% to 25% 9,5% to 50%

Maximum deviation
±2°C (0-30°C) ±15% Not defined ±3% of measured value Not defined ±3% of measured value Not defined

Connection

NB-IoT (LTE Cat NB1) B20. Power 23 dBm

Batteries Battery time

2 x AA/LR6 1,5V (not included) Depending on the transmission interval. Example at 20°C, good signal quality, measurement every hour and transmission every 3 hours: > 12 months

Measurement and transmissi- Adjustable by users via the Celsiview cloud service.

on interval

Memory

200 measurements

Size

MM611 enclosure, 78 (w) x 114 (h) x 30 (d) mm

Weight Certificate
Mounting method

MM601, 148 grams (without battery) CE Mounted vertically with the screw holes facing upwards NOTE! If the sensor is to be mounted against metal, magnetic mount 7040 0060 can be used. (Or other 10 mm spacer, not made of metal)

Celsicom AB Härdgatan 28 A, 432 32 Varberg
SVERIGE celsicom.se support.celsicom.se
Version of user manual: 1

Made in Sweden



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Macintosh)