User Manual for KMDES models including: WTM-W1-A Wireless Digital Microscope, WTM-W1-A, Wireless Digital Microscope, Digital Microscope, Microscope

WTM-W1-A-Z01-Z06B支架-英文-99x150

User Manual (PDF)

Wireless Digital Microscope KMDES Handheld USB HD Inspection Camera 50X-1000X Magnification with Metal Stand Upgrade No Shake, Adjustable 8 LED Lights,Portable Microscope for PC Phone Compatible-Blue : Electronics


File Info : application/pdf, 13 Pages, 1.56MB

PDF preview unavailable. Download the PDF instead.

A1yG2f77 IL
Electron Microscope
Model: WTM-W1-A
User Manual
Please read this user manual carefully and keep it for future reference.

Contents
Read Me First...................................................................... 03 Packing List......................................................................... 03 Bracket Installation........................................................... 04
Plastic Bracket................................................................. 04 Metal Bracket.................................................................. 04 Parts Description................................................................ 05 Detailed Operation........................................................... 06 1. How to zoom in and focus?....................................... 06 2. Work with cell phone................................................. 07
Download the App.................................................... 07 Operating steps.......................................................... 07 Introduction of the APP.............................................. 09 3. Work with Windows..................................................... 10 Software download.................................................... 10 Operating steps...........................................................10 4. Work with Mac/iMac.................................................. 11 Software download.................................................... 11 Operating steps...........................................................11 Product Parameters........................................................... 12 Troubleshoot the Microscope...........................................13

Read Me First
Thank you for purchasing the WTM-W1-A WiFi digital microscope.
Please read this user manual carefully and keep it for future reference.
Pay attention to protect the lens part. Close the lens lid after using to avoid entering dust or strange objects.
The microscope can be used in hand or inserted as a desktop, with attention to avoid damage to the components.
When placing items, place them directly below the center of the lens as much as possible. Avoid not seeing objects clearly and bringing about a bad experience.
Packing List

Microscope

Plastic / Metal Bracket

Type-C Date Cable

User Manual

Calibration Card

( NoticeThe package contains only one of the brackets. Please refer to the purchase order )
03

Bracket Installation
( Notice: Accessories contain only one type of bracket. Please refer to the bracket installation procedure corresponding to the purchase order )
Plastic Bracket

Step 1

Step 2

Metal Bracket

Step 3

Step 1

Step 2
04

Step 3

Parts Description
* Before using the microscope, make sure your hands are secured, or use it on the desktop.
Monomer Microscope
The core components were observed by microscope

Focus Wheel
Multiple Regulation microscopy optical
focus modulation
Power Button
Turn on /off Button
Reset Hole
Resume Factory Setting
Photo Button
Take a Photo and Save the
Captured Screen
05

Lens Cap
Dust-proof, protect lens
Fill Light Bright Button
Lens Barrel Fill Light brighten
Fill Light Dim Button
Lens Barrel Fill Light Dimming

Type-C Interface
Connect the computer
for use/charging

Indicator Light
After connecting the computer through the data cable, the indicator lightç is steady on
Indicator Light
After the microscope is turned on, the indicator lightæ flashes; after the mobile phone is successfully connected, the indicator lightæ is steady on

You can use a daily mobile phone charger, computer, and charger to charge the microscope.

+12h

The charging time

should not exceed 12

hours to avoid affecting

the battery life.

During the charging process, if the microscope shell and the battery are slightly heated, please rest assured to use the normal phenomenon.

Detailed Operation
1. How to zoom in and focus?

Counter-Clockwise Rotation: multiple magnification
Clockwise Rotation: multiple reduction
(Note: At the same distance, the rotating zoom cylinder has two magnification. To adjust more multiples, it can be adjusted up and down through the microscope base bracket.)
06

2. Work with cell phone
Download the App
Scan the QR code, click download and install. The mobile terminal is the iOS system, and you can search for "Uni Lab" at APP Store for download
Operating steps
Step 1 Turn on the microscope Long press the power button for 3s, and the blue light flashes under the button after turning on, indicating that the app has not been connected yet. Step 2 Connect the microscope to Android / iOS æ Open the Uni Lab APP, click WiFi, jump to the WiFi connection page of the Android / IOS device, select the corresponding network name of the product "WTM-W1-XXXXXX" (network without encryption) ç Connect to the network. If the connection confirmation prompt appears, please click "Keep Connected"(Android version) / click "OK" è After the connection is successful, the microscope blue lights on. When you return to the app, you can see the image on your phone. (Note: Please open the phone / tablet location permission when the APP is connected to the microscope.)
07

Run the APP, and follow the indicated operation steps. (Follow the red box instructions to make the selection)











08

Introduction of the APP
APP Homepage * Because of the mobile phone model version is different, the pictures are for reference only
Photo Video Zoom In Zoom Out Photo: Select a photo mode Video: Select the recording mode Zoom in: Click to zoom in on the screen (use when the screen is too small) Zoom Out: Click to zoom out the screen (used when the screen is too large, the default is the smallest each time it is opened)
09

3. Work with Windows
Software download
* The device camera button cannot be used, it can only be realized through software Photo recording function æFor Windows 8, Windows 10 or higher system, search "UniLab"(as shown in "  ") in the Microsoft Store to download it. çFor Windows 7 and Windows XP, download the software from the websitehttp://www.weetool.net
Operating steps
Step 1 With the microscope turned off, connect the microscope to the computer using a data cable. Step 2 Turn on the microscope, run the software, select the corresponding device name, you can see the image on the computer, and take photos and videos through the software.
10

4. Work with Mac/iMac
* The device camera button cannot be used, it can only be realized through software Photo recording function
Software download
For Mac OS x 10.5 or higher system, use the default software "Photo Booth"(as shown in "  ")
Operating steps
Step 1 With the microscope turned off, connect the microscope to the computer using a data cable. Step 2 Turn on the microscope, run Photo Booth, you can see the image on the computer, and take photos and videos through Photo Booth
11

Product Parameters

Project

Parameter

Picture Format Picture Size
LED Quantity
Focus Mode and Focus Range

JPG 1920*1080 8 SMD 3528 bright white lights (brightness adjustable)
Manual adjustment, 0 to 40 mm

Imaging Distance
Sensor Size Sensitivity Video Recording Format

3mm to Infinity 1/4" 4300mV/lux-sec
AVI

Video Resolution Working Range Working Hours

1920*1080 0-10mcOpen scene, Sheltered scene will affect working range 1.5h

Power Supply Mode 700mAh Charging Requirements DC-5V~1A

Charging Time

1.5h

Working Current The WiFi Working Environment
PC Operating System

~260mA
Android 4.0 and above systems, ios 8.0 and above systems
Windows xp, win 7, win 8, win10 , Mac OSx10.5 or higher

12

Troubleshoot the Microscope

Problem Phenomenon

Cause

Processing Method

The device heats up during charging

During the charging process,the current is large and the battery heat is high,which is a normal phenomenon

The normal state

The APP is disconnected

æ The distance is too far ç The device is powered off è Equipment failure

æ Close distance repeat connection ç Charge the device and use it è Close the APP and restart the device before use

The device cannot be charged

æ The charging port is not securely inserted ç No power is connected è Equipment failure

æ Remove and reinsert the interface ç Switch on the power

The lens shows blurred images

The ambient temperature changes rapidly, causing the lens to fog

Wait for the temperature balance, a period of time after the fog disappeared to use

The product can not be shut down or the key failure

System halted

Please plug in the power supply to reset and restart

(Note: It is normal for the APP to exit after being plugged in.) 13



References