Installation Guide for nVent RAYCHEM models including: RayClic, RayClic Connection System, Connection System
RayClic Connection Kit | nVent RAYCHEM
RayClic Connection Kit | nVent DATA-SOLUTIONS
File Info : application/pdf, 10 Pages, 2.15MB
DocumentDocumentRayClic Connection System Installation Instructions APPROVALS 718K Pipe Heating Cable 877Z De-Icing and Snow Melting Not UL Listed with XL-Trace Edge heating cable for buried piping For HWAT and IceStop only Hazardous Locations: For IceStop (GM-XT) only Class I, Div. 2, Groups A, B, C, D DESCRIPTION nVent RAYCHEM RayClic-S Splice Kit nVent RAYCHEM RayClic-T Tee and End Seal Kit nVent RAYCHEM RayClic-X Cross and End Seal Kit These kits are for use with nVent RAYCHEM IceStop, XL-Trace Edge and HWAT heating cables. The connection is designed to be strapped to the pipe, or wall mounted. These installation instructions should be used in conjunction with the IceStop, XL-Trace Edge, and HWAT System Installation and Operation Manuals. For technical support, contact your nVent representative or call nVent (800) 545-6258. TOOLS REQUIRED · TORX T20 screw driver · Utility knife · Wire cutters OPTIONAL ACCESSORIES (NOT INCLUDED IN THIS KIT) · nVent RAYCHEM RayClic-SB-02 Wall mounting bracket · nVent RAYCHEM RayClic-SB-04 Pipe mounting bracket WARNING: This component is an electrical device that must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all the installation instructions. · To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of nVent, agency certifications, and national electrical codes, ground fault equipment protection must be used. Arcing may not be stopped by conventional circuit breakers. · Bus wires will short if they contact each other. Keep bus wires separated. · Keep components and heating cable ends dry before and during installation. · The black heating cable core is conductive and can short. It must be properly insulated and kept dry. · Component approvals and performance are based on the use of nVent-specified parts only. Do not use substitute parts or vinyl electrical tape. · Leave these instructions with end user for reference and future use. nVent.com/RAYCHEM | 1 KIT CONTENTS RAYCLIC-S SPLICE KIT Item Qty A 1 B 2 C 2 D 3 E 1 Description Splice Plastic cable ties Clips Labels (1 splice, 2 warning) Cable lubricant RAYCLIC-T TEE KIT Item Qty A 1 B 2 C 3 D 1 E 3 F 1 Description Tee Plastic cable ties Clips End seal Labels (1 splice, 2 warning) Cable lubricant RAYCLIC-X CROSS KIT Item Qty A 1 B 2 C 4 D 2 E 3 F 1 Description Cross Plastic cable ties Clips End seals Labels (1 splice, 2 warning) Cable lubricant A B C D E A B C D E F A B C D E F 2 | nVent.com/RAYCHEM If you experience difficulty during installation, refer to the "Troubleshooting Guide" on page 8. For pipe-mounted applications follow steps 1 through 10 (pages 35). Splice, Tee, and Cross Installation 1 For roof-mounted applications, follow steps 2 through 9 (pages 35), then turn to "Roof Installation" on page 6. 2 · Place kit on pipe and attach with plastic cable ties. 3 · Allow enough extra heating cable to make service loops as required. · Make sure the end of the heating cable is cut clean. 4 Do not cut through metal braid or inner jacket. · Score around and down the outer jacket of the heating cable 3 1/8 inches from the end. · Remove the outer jacket. · Place the metal clip over the base of the exposed braid. nVent.com/RAYCHEM | 3 HWAT Only 5A IceStop and XL-Trace Edge Only 5B · Using wire cutters, cut away 1 inch of the braid. · Pull exposed braid back over metal clip. · Pull exposed braid back over metal clip. · Using wire cutters, cut away aluminum wrap. 6 7 · Apply a small amount of lubricant to the jacket surface near sthuerfeancde onfeathrethceabelned. of the cable. · Avoid using large amounts of lubricant on the exposed end eoxf pthoesecdabelned. of the cable. · Insert prepared heating cable ·enIdnsinetrot pcroenpnaerecdtohr.ePautisnhgucnatbille heeantdinigntcoabcoleninsefcutlolyr.inPsuesrhteudnatinl hdeating encdaibsleviissibfulellythinrosuegrtheodpaenndinegndinis visible cotnhnroeucgtihonopceonvienrgpilnatceo. nnection cover plate. NoNtoet:eH: eHaetaintgincgacbaleblceacnannontobtebreermemovoevde.dT.hTehceocnonnencetciotnion anadnednednsdesaelaalraerdeedseigsnigendetdotboebiensintsatllaeldleodnolynloynocnec;eth; tehe hehaetaintgincgacbaleblceacnannontobtebreermemovoevdeodnocneciensintsatllaeldle.d. 4 | nVent.com/RAYCHEM 8 9 Tighten the screws until the metal top surface is at the same height as the inner clear plastic module. · Securely tighten the two connection screws, alternating as they are being tightened. WARNING: Fire hazard. Loose screws can cause excessive heating. Be sure screws are fully tightened. 10 · Repeat steps 2 through 7 for all remaining heating cable entries. 11A SPLICE · Close the lid and snap the lever shut. Do not force lid closed. If lid does not close, check the connection to ensure all screws are fully tightened. · Tighten the nuts on the heating cable entries until grommets are compressed. 11B TEE (insulation not shown) R ® · Using glass cloth tape, attach heating cable to pipe. · Apply insulation, cladding, warning labels and yellow splice identification label. CROSS 11C (insulation not shown) · Using glass cloth tape, attach heating cable to pipe. · Apply insulation, cladding, warning labels and yellow splice identification label. · Using glass cloth tape, attach heating cable to pipe. · Apply insulation, cladding, warning labels and yellow splice identification label. nVent.com/RAYCHEM | 5 Roof Installation 1 2 RayClic-SB-02 · Mount flat (wall-mounting) bracket by installing screws through the center holes. · Mount bracket above water line. Do not mount in gutter or where it may be immersed in water. RayClic-S RayClic-T and RayClic-X · Position attachment clips on mounting bracket based on the type of connector being installed. 3 4A SPLICE · Prepare and attach heating cables as detailed in steps 2 through 9 (pages 35). 4B TEE Drip loops · Attach connector to mounting bracket by pressing until it snaps into place. · Complete heating cable installation and install drip loops as shown. · Protect heating cable from sharp edges. 6 | nVent.com/RAYCHEM Drip loops · Attach connector to mounting bracket by pressing until it snaps into place. · Complete heating cable installation and install drip loops as shown. · Protect heating cable from sharp edges. End Seal Installation 1 1" · Score down and around outer jacket 1 inch from the end. · Remove the outer jacket. · Do not cut or damage inner jacket. HWAT 2A · Using wire cutters, cut away aluminum wrap close to braid and outer jacket. 2 · Remove exposed braid. IceStop, XL-Trace Edge and RaySol 3 · Push end seal completely onto heating cable. Note: The end seal can be installed only once; it cannot be removed from the heating cable. Do not use until ready for final installation. nVent.com/RAYCHEM | 7 Troubleshooting Guide PROBLEM Braid clips are missing. Mounting bracket is missing. Connector does not snap onto bracket. Heating cable type not mentioned. Braid clip does not fit. Heating cable does not have aluminum wrap. Heating cable cannot be inserted into connector. Lid does not close. Heating cable cannot be inserted into end seal. Heating cable cannot be removed. SOLUTION The braid clips are attached to the cardboard packing insert under the lid. The braid clips must be used to ensure a ground connection. If clips are missing or lost, call nVent at (800) 545-6258. A mounting bracket is not included in the splice, tee and cross kits. One can be ordered using one of the catalog numbers listed under "Optional Accessories" on the front page of these instructions when you place your order. The bracket has two sets of attachment clips. Fold up the four outer clips for the splice kit. Fold up only the center clips for the tee and cross kits. nVent RAYCHEM RayClic connection kits are approved for use only with HWAT, XL-Trace Edge and IceStop heating cables. Do not use with other heating cables. Be sure the clip is installed on the metal braid, not on the outer jacket. Only HWAT heating cables have the aluminum wrap under the braid. Skip the aluminum wrap removal step for XL-Trace Edge and IceStop heating cables. Check for the following: · Apply cable lubricant to the heating cable primary (white) jacket. · Outer jacket strip length is 3 1/8 inches. · Braid clip is installed on top of the metal braid, not on the outer jacket. · Braid is pulled back over braid clip. · For HWAT, 1 inch of braid is removed. · Sealing nut is loose (but not removed). · Connection screws are loose. Be sure all screws are fully tightened before closing the lid. The outer jacket must be removed from the heating cable before the end seal is installed (see the "End Seal Installation" instructions on page 7). Make sure 1 inch of the outer jacket, braid, and aluminum wrap (HWAT only) are removed. The connection and end seal are designed to be installed only once; the heating cable cannot be removed once installed. Additional nVent RAYCHEM RayClic-E end seals can be ordered from nVent. 8 | nVent.com/RAYCHEM Heating Cable Circuit Testing The RayClic-T now includes test ports in the blank module. Voltage can measured at these points to confirm continuity or power to the installed heating cable circuit. For detail heating cable operation refer to the appropriate installation and operating manual. Instructions: 1. Open the RayClic cover. 2. Set multimeter to AC voltage function. 3. Insert multimeter test probes into the two test ports. WARNING: To avoid shock do not cross the test probes or touch them to the metal pressure plate when measuring voltage. Test ports nVent.com/RAYCHEM | 9 North America Tel +1.800.545.6258 Fax +1.800.527.5703 thermal.info@nVent.com Europe, Middle East, Africa Tel +32.16.213.511 Fax +32.16.213.604 thermal.info@nVent.com Asia Pacific Tel +86.21.2412.1688 Fax +86.21.5426.3167 cn.thermal.info@nVent.com Latin America Tel +1.713.868.4800 Fax +1.713.868.2333 thermal.info@nVent.com nVent.com/RAYCHEM ©2021 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. RAYCHEM-IM-H55388-RayClicConnectionKits-EN-2111 PN 473303-000