User Manual for MICROTECH models including: 120129018 Computerized Test Indicator, 120129018, Computerized Test Indicator, Test Indicator, Indicator

MICROTECH

MICROTECH Parameters LED display color 1,54 inch Resolution 240x240 Indication system MICS 3.0 Power supply Rechargeable Li-Pol battery Battery capacity 350 mAh


File Info : application/pdf, 12 Pages, 947.65KB

PDF preview unavailable. Download the PDF instead.

COMPUTERIZED TEST INDICATOR 2022 (1)
MICROTECH

SUB-MICRON COMPUTERIZED TEST INDICATOR

ISO17025:2017

ISO 9001:2015

USER MANUAL

MICROTECH

SPECIFICATION

Item No

Range

mm

inch

Resolution

Accuracy

Probe Lenght Ball

Measuring Force

Protection

Display

mm

m mm

N

Data output

120129018 -0.8- +0.8 -0.03" - +0.03" 0,0001 120129038 -1.6 - +1.6 -0.06" - +0.06"

±5 ±10

30 Ruby 0,1-0,18 16 Steel 0,15-0,25

IP54 IP54

Color 1.5" Touch-screen

WIRELESS+USB

Free Software for Windows, Android, iOS
Multifunctional button

MICS indication system hi-res colour Touchscreen

0.1m

TECHNICAL DATA
Parameters
LED display Resolution Indication system Power supply Battery capacity Charging port Case material Buttons Wireless data transfer

MICROTECH
color 1,54 inch 240x240 MICS 3.0
Rechargeable Li-Pol battery 350 mAh micro-USB Aluminium
Switch (Multifuntional), Reset Long range

CHARGING
BUILT-IN BATTERY - rechargeable Li-Pol battery For charging connect USB cable Charging process indicating on Battery status (switch on device)

MICROTECH

WIRELESS DATA TRANSFER

Activate WIRELESS data transfer in WIRELESS menu

Switch on Wireless data transmition
Activating multifunctional button to save value to memory or send data by touchscreeb ur button push

Connect instrument with MICS indication system to Tablet or PC Send data tp Tablet or PC: - by Touchscreen - by Multifactinal button psuh (activted in Wireless menu) - by Timer (activated in Timer menu) - from Internal Memory
MEMORY
For save measuring data to internal caliper's memory touch data area on screen or short button push. You can view saved data throw menu or send Wireless connection to Windows PC, Android or iOS devices.

Basic STATISTIC functions: MAX - maximum saved value MIN - minimum saved value
AVG - average value D - variance VAR(x)
Memory sub-menu

Saved values Each value can be Deleted or Send to
application
MEMORY settings

Button ALL select all values All values can be Deleted or Send to application
Selecting Standard mode or No saving data to internal memory

CONNECTION

MICROTECH

USB-DONGLE

WIRELESS CONNECTION

IMPORT FROM FILE OR CAMERA

IOS

DOWNLOAD DOWNLOAD DOWNLOAD

SAVING DATA TO XLS. CSV FORMATS

SAVING DATA TO XLS. CSV FORMATS

TRANSFER DATA TO CAD, SPC OR OTHER
SOFTWARE

SAVING GRAPH

TRANSFER DATA TO

EXCEL OR OTHER

VOICE

TABLE EDITORS

MODE

DATA TRANSFER DISTANCE FOR INTELLIGENT INSTRUMENTS
·All MICROTECH Intelligent instruments has internal memory. You can collect data to memory and when it will be neccesary transfer all data to the peripheral device with no data loosing. ·It's possible transfer data, like in Wireless instruments up to 15 m or up 50 m with external antenna ·USB port can be used to transfer data directly to Windows PC

SAVING DATA TO XLS. CSV FORMATS
SAVING GRAPH
VOICE MODE
QUALITY CONTROL RESULTS

MICROTECH

MENU NAVIGATION
USE TOUCHSCREEN TO OPERATE MENU

MENU button Colour can be changed
according function Zero setting
MENU CONFIGURATION

Battery level Actual value Memory

MEMORY WITH STATISTIC

MAIN MENU

LIMITS
color Go/NoGo

ERROR COMPENSATION mathematical correction

WIRELESS
modes of data transmition

MEMORY SETTING

MAX/MIN
indicating max or min value

TEMPERATURE COMPENSATION

USB

manual correction

USB connection configuration

SOFTWARE
link to download app

FORMULA MODE
Ax2+Bx+C

RESOLUTION
selected up to 0.0001mm

DEVICE SETTING
pin, reset

CALIBRATION DATE

MICS SYSTEM FUNCTIONS

MICROTECH

LIMITS GO/NOGO

MENU SETTING
MAX value MIN value
zero values

Colour indication limits
MAX - NoGo more MAX value MIN - NoGo less MIN value RANGE - Go between MIN & MAX NONE - disactivating mode

MAIN SCREEN INDICATION

NoGo

Go

MAX/MIN

MENU SETTING

Indication and saving MAX or MIN values MAIN SCREEN INDICATION

ENABLE - activating mode MAX - indicating MAX measured value MIN - indicating MIN measured value
FORMULA

MIN

MAX

MENU SETTING
Formula:
Ax2+Bx+C

FORMULA Ax2+Bx+C

EXAMPLE OF FORMULA USING

Long push digit

Standard measuring A=0, B=1, C=0

to select value

PRESET 50mm

A=0, B=1, C=50

Value magnification x3 A=0, B=3, C=0

Reset to zero arguments Square value

A=1, B=0, C=0

TIMER

MENU SETTING

Saving data to memory or sending Wireless by Timer

Select timer period Reset to disactivate mode

MICROTECH

MICS SYSTEM FUNCTIONS

MATHEMATICAL ERROR COMPENSATION

MENU SETTING

Mathematical correction points with big error to normal values

Select all points

actual values

Add new point for error compensation

correct values by up&down button confirm point correction

use gauge blocks or measuring machine for points correction
TEMPERATURE COMPENSATION

MENU SETTING Re-calculation detail size to calibration conditions (20°C)
7 types of material for selection Manual Temperature setting
RESOLUTION

7 types of material: - glass, quartz, solid alloys - granite, graphite - Fe, NI, Fe alloys - stainless steel - cooper, Cu alloys - alluminium, al alloys - acrylic sheet

MENU SETTING

MAIN SCREEN INDICATION

Resolution selecting mm/inch conversion

Selecting resolution of value on main screen and memory

EXTRA (Axis mode)
MENU SETTING
Selecting normal or inverted axis mode (+/- value indication)
Reading base reconnection for some types of calipers

MICS SYSTEM FUNCTIONS

MICROTECH

MENU SETTING

WIRELESS CONNECTION
Activating or disactivating wireless data transfer

Switch on Wireless or USB data transmition
Activating multifunctional button to save value to memory or send data by touchscreeb ur button push

USB CONNECTION

MENU SETTING

Connect instrument with USB cable to PC or iother device Switch ON USB data transmition in Wireless menu Select in this menu data transfer format Data will be send to PC or other evice in keyboard mode
Don't switch off USB cable during data transfer

MENU SETTING

PIN & RESET
Activating PIN to device setting

RESET to factory settings

DISPLAY SETTING

MENU SETTING

DISPLAY ROTATION, BRIGHTNESS, SLEEPING MODE

Display rotation 0°, 90°, 180°, 270° - Sleep OFF (15 s low brightness off, sleep off) - Sleep 15s (15 s low brightness on, sleep off) - Sleep ON (15 s low brightness on, sleep on)

MICROTECH

MICS SYSTEM FUNCTIONS

MENU SETTING

MEMORY SETTINGS
Activating or disactivating saving values to memory
Standard - saving values to memory OFF - disable saving to memory

MENU SETTING MENU SETTING

LINK TO SOFTWARE
QR Link to MICROTECH web site page with MDS Software download - Android, iOS, Windows versions - Free and Pro versions - Manuals
CALIBRATION DATE
Calibration date info

MENU SETTING

Push for change date info
DEVICE INFO
Information about device - device name - firmware version - MAC adress for easy connection

IOS

MICROTECH

0,1m

AX²+BX+C

TEMP
COMPENSATION

ISO 17025
CALIBRATION

MEMORY

LIMITS

LI-POL
BATTERY

MAGNETIC
CHARGER

TIMER

LINEAR
CORRECTION

USB
HID

TOUCHSREEN

MICROTECH

MICROTECH innovative measuring instruments
61001, Kharkiv, Ukraine, str. Rustaveli, 39
tel.: +38 (057) 739-03-50 www.microtech.ua tool@microtech.ua

Change without prior notice



References

Adobe PDF Library 15.0 Adobe InDesign CC 13.1 (Macintosh)