User Manual for ADAMSON models including: IS7p, Full-Range PA Speaker Cabinet, IS7p Full-Range PA Speaker Cabinet, PA Speaker Cabinet, Speaker Cabinet, Cabinet
Copyright 2021 by Adamson Systems Engineering Inc.; all rights ... This manual must be accessible to the person operating this product.
amon Sem ngineeing IS7p e ana Page 5 IS7p IS7p Jackplate IS7pb Jackplate IS7p & IS7pb Internal Wiring (IS7pb only has one input) • The IS7p (70x40 - 967-0001/100x50 - 967-0003) comes with 2x Neutrik Speakon™ NL4 connections, wired in parallel. • The IS7pb (70x40 - 967-0002/100x50 967-0005) comes with an external barrier strip. • Pins 1 /- are connected to the 2x ND7-LM16 MF transducers ...
File Info : application/pdf, 8 Pages, 8.83MB
DocumentDocumentTable of Contents ______________________________________________________________________________________ 3 ______________________________________________________________________________________ 4 ______________________________________________________________________________________ 5 ______________________________________________________________________________________ 6 ______________________________________________________________________________________ 7 ______________________________________________________________________________________ 8 Safety & Warnings Read these instructions, keep them available for reference. This manual can be downloaded from Heed all warnings and follow all instructions. A qualified technician must be present during the installation and use of this product. This product is capable of producing extremely high sound pressure levels and should be used according to the specified local sound level regulations and good judgement. Adamson Systems Engineering will not be liable for damages caused by any possible misuse of this product. Servicing is required when the loudspeaker has been damaged in any way, such as when the loudspeaker has been dropped; or when for undetermined reasons the loudspeaker does not operate normally. Protect the cabling from being walked on or pinched. Read the appropriate IS-Series Rigging Manual before installing the product. Pay attention to rigging instructions included in both Blueprint AVTM and the IS-Series Rigging Manual. Use only with the rigging frames/accessories specified by Adamson, or sold with the loudspeaker system. This speaker enclosure is capable of creating a strong magnetic field. Please use caution around the enclosure with data storage devices such as hard drives. In an effort to continuously improve its products, Adamson releases updated accompanying software, presets and standards for its products. Adamson reserves the right to change the specifications of its products and the content of its documents with no prior notice. Adamson Systems Engineering | IS7 User Manual Page 1 IS7p User Manual Distribution Date: March 1st, 2021 Copyright 2021 by Adamson Systems Engineering Inc.; all rights reserved This manual must be accessible to the person operating this product. As such, the product owner must store it in a safe place and make it available upon request to any operator. Resale of this product must include a copy of this manual. This manual can be downloaded from https://www.adamsonsystems.com/en/support/downloads-directory/is-series/is7p Declarations EU Declaration of Conformity Adamson Systems Engineering declares that the products stated below are in conformance with the relevant fundamental health and safety criteria of the applicable EC Directive(s), in particular: Directive 2014/35/EU: Low Voltage Directive 967-0001 IS7p - 70 x 40 967-0002 IS7pb - 70 x 40 967-0003 IS7p - 100 x 50 967-0004 IS7pb - 100 x 50 Directive 2006/42/EC: Machinery Directive 930-0031 IS7p & IS10p Fill Plate 930-0032 IS7p Short Fill Plate 934-0027 IS7p Horizontal Bracket 934-0028 IS7p Vertical Bracket 934-0026 IS-Series Sight Mount 932-0006 Bracket C-Clamp 932-0039 IS-Series Pole Mount Adapter 932-0040 IS-Series C-Clamp 932-0041 IS-Series Point H-Clamp 932-0042 IS-Series Tilt Adaptor 932-0044 IS-Series Sight Mount LInk 934-0031 IS-Series Super Sight Mount 934-0032 IS-Series Articulator Signed at Port Perry, ON. CA - March 1st, 2021 -----------------------------------------------Brock Adamson (President & CEO) ADAMSON SYSTEMS ENGINEERING, Inc. 1401 Scugog Line 6, Port Perry (ON), L9L 1B2, Ontario, Canada T: +1 905 982 0520, F: +1 905 982 0609 Email: info@adamsonsystems.com Website: www.adamsonsystems.com Table of Contents 1. Safety & Warnings ______________________________________________________________________________________ 3 2. Product Introduction ______________________________________________________________________________________ 4 3. Wiring ______________________________________________________________________________________ 5 4. Amplification ______________________________________________________________________________________ 6 5. Presets & Control ______________________________________________________________________________________ 7 6. Technical Specifications ______________________________________________________________________________________ 8 Safety & Warnings Read these instructions, keep them available for reference. This manual can be downloaded from https://www.adamsonsystems.com/en/support/downloads-directory/is-series/is7p Heed all warnings and follow all instructions. A qualified technician must be present during the installation and use of this product. This product is capable of producing extremely high sound pressure levels and should be used according to the specified local sound level regulations and good judgement. Adamson Systems Engineering will not be liable for damages caused by any possible misuse of this product. Servicing is required when the loudspeaker has been damaged in any way, such as when the loudspeaker has been dropped; or when for undetermined reasons the loudspeaker does not operate normally. Protect the cabling from being walked on or pinched. Read the appropriate IS-Series Rigging Manual before installing the product. Pay attention to rigging instructions included in both Blueprint AVTM and the IS-Series Rigging Manual. Use only with the rigging frames/accessories specified by Adamson, or sold with the loudspeaker system. This speaker enclosure is capable of creating a strong magnetic field. Please use caution around the enclosure with data storage devices such as hard drives. In an effort to continuously improve its products, Adamson releases updated accompanying software, presets and standards for its products. Adamson reserves the right to change the specifications of its products and the content of its documents with no prior notice. Adamson Systems Engineering | IS7 User Manual Page 3 IS7p IS7p Ultra Compact Point Source · The IS7p is an ultra-compact point source enclosure. It contains two symmetrically arrayed 7" LF transducers and a 3" HF compression driver mounted on an Adamson waveguide, available in two configurations; with dispersion patterns of either 70° x 40° (HxV) or 100° x 50° (HxV) each rotatable in increments of 90°. · The operational frequency range of the IS7p is 80Hz to 18kHz. The use of proprietary techologies such as Advanced Cone Architecture allows high maximum SPL of 136.5 dB. · The enclosure has an unobtrusive visual design which blends seamlessly into the surrounding space, is made of marine grade birch plywood, and has steel rigging discs on the top, bottom, and on each side, to be used with a wide variety of rigging accessories. Without sacrificing low resonance to composite material, the IS7p weighs only 15 kg / 33.1 lbs. · The IS7p is intended to be used as either a standalone system, or a fill enclosure in tandem with other IS-Series products. The IS7p is designed to pair easily and coherently with all IS-Series subwoofers. · The IS7p is designed for use with Lab.gruppen's D-Series line of installation amplifiers. The nominal impedance of the IS7p is 8 per band, maximizing amplifier efficiency. Adamson Systems Engineering | IS7p User Manual Page 4 IS7p Wiring · The IS7p (70x40 - 967-0001/100x50 - 967-0003) comes with 2x Neutrik SpeakonTM NL4 connections, wired in parallel. · The IS7pb (70x40 - 967-0002/100x50 967-0005) comes with an external barrier strip. · Pins 1+/- are connected to the 2x ND7-LM16 MF transducers, wired in parallel. · Pins 2+/- are connected to the NH3-8 HF transducer. p p PARALLEL IS7p Jackplate 2+ PARALLEL 2INPUT 1+ 1- IS7pb Jackplate MF HF 2+ PARALLEL 2- INPUT 1+ MF 1- IS7p & IS7pb Internal Wiring (IS7pb only has one input) Adamson Systems Engineering | IS7p User Manual Page 5 IS7p Amplification The IS7p is paired with Lab.gruppen D-Series amplifiers. Maximum quantities of the IS7p per amplifier model are shown below. For a master list, please refer to the Adamson Amplification Chart, found on the Adamson website. https://adamsonsystems.com/support/downloads-directory/is-series/is7p/327-max-enclosures-peramplifier-v5-0-1-7-1-1 D40:4L 3x IS7p D80:4L 8x IS7p D120:4L Enclosure IS7p #1 IS7p #2 12x IS7p Frequency Band LF HF LF HF Output Channel 1 2 3 4 Cable #1 (Pin 1, +/-) #1 (Pin 2, +/-) #2 (Pin 1, +/-) #2 (Pin 2, +/-) Adamson Systems Engineering | IS7p User Manual Page 6 IS7p Presets The Adamson Load Library, found on the Adamson website, contains presets designed for a variety of IS7p applications. Furthermore, there are presets designed to pair with either Adamson subs, or Adamson Line Arrays. For a master list, please refer the Adamson PLM & Lake Handbook, found on our website. https://adamsonsystems.com/support/downloads-directory/design-and-control/e-rack/205-adamson-plm-lakehandbook Cabinet Configuration Applicable Preset Cabinet Configuration IS7p FR Fullrange Mode IS7p FR LP Fullrange Mode Linear phase response matching Adamson Line Arrays IS7p Xo80 Low Cut at 80 Hz Add 5ms of delay for alignment of IS-Series Subs at same distance IS7p Xo80 LP Low Cut at 80 Hz Linear phase response matching Adamson Line Arrays Adamson Systems Engineering | IS7p User Manual Page 7 IS7p Technical Specifications 180° 90° 0° 90° 180° 100 Hz 200 Hz 400 Hz 800 Hz 1.5 kHz 3 kHz IS7p 70x40 Horizontal Pattern 6 kHz 10 kHz 20 kHz 180° 90° 0° 90° 180° 100 Hz 200 Hz 400 Hz 800 Hz 1.5 kHz 3 kHz IS7p 100x50 Horizontal Pattern 6 kHz 10 kHz 20 kHz 527 mm / 20.75 in 170 mm / 6.7 in 251.5 mm / 9.9 in Frequency Range (- 6 dB) 80 Hz - 18 kHz Nominal Directivity (-6 dB) H x V Maximum Peak SPL** Components LF Components HF Nominal Impedance LF Nominal Impedance HF 70° x 40° / 100° x 50° 136.5 2x ND7-LM16 7" Neodymium Driver NH3-8 3" Diaphragm / 1.4" Exit Compression Driver 8 (2x 16 ) 8 Power Handling (AES / Peak) LF Power Handling (AES / Peak) HF Rigging 500 / 2000 W 110 / 440 W Integrated Rigging System Connection Height (mm / in) 2x SpeakonTM NL4 or Barrier Strips 527 / 20.75 Width Front (mm / in) 251.5 / 9.9 Width Rear (mm / in) 170 / 6.7 Depth (mm / in) 356 / 14 Weight (kg / lbs) 15 / 33.1 Colour Black & White (Standard), RAL Colours (On Demand) Processing Lake **12 dB crest factor pink noise at 1m, free field, using specified processing and amplification 356 mm / 14 in Adamson Systems Engineering | IS7p User Manual Page 8