Instruction Manual for pulsar models including: AWO-513 Enclosure for BOSCH Access Control System Small, AWO-513 Enclosure for BOSCH Access Control System Small, Enclosure for BOSCH Access Control System Small, Control System Small

1

Pulsar

Stáhnout

AWO-513 Plechová skøíò s DIN lištou - ATIS KOUKAAM - JSME ZABEZPEÈENÍ


File Info : application/pdf, 2 Pages, 195.37KB

PDF preview unavailable. Download the PDF instead.

awo513-instal-man-eng-2
INSTALLATION MANUAL ENGLISH
Code: AWO 513 Name: Enclosure for BOSCH Access Control System small

1. Application:

IM513
Edition: 2 from 01.03.2018 Supercedes edition: 1 from 02.01.2017

The AWO513 enclosure is designed for mounting (depending on the configuration):  The AMC (Access Modular Controller) of the access control system on a TH/TS35 (35mm) DIN rail  Power supply of the PCB on a TH/TS35 (35mm) DIN rail  Additional modules or other devices adapted for mounting on a TH/TS35 (35mm) DIN rail  batteries 2x7Ah/12V
2. Product description

The enclosure is fitted with a bottom mounted DIN rail with a length of 380mm at mounting distances with a height of 18mm, allowing cable routing under the enclosure. The enclosure has a battery compartment for two 7Ah / 12V batteries. The set includes a tamper switch (indicating unwanted removal of the enclosure from the wall). In the standard option, the enclosure is fitted with a key lock with the same code ­ MR027. A preview pane of the AMC status, protected with polycarbonate glass, is located at the front panel. The 14mm distance from the wall at the bottom makes it easier to connect wires to the devices mounted in the enclosure. The enclosure is fitted with plugs and cables required for assembling process.
3. Mounting:

The enclosure is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC in and low-voltage installations.
The enclosure should be mounted in confined spaces with normal relative humidity (RH=90% maximum, no condensation) and temperature range from -10°C up to +40°C.

4. Technical parameters
TECHNICAL PARAMETERS Battery space
Tamper protection
TAMPER output load- max Enclosure: IP
Operation temperature Relative humidity RH ­ max. External dimensions of the enclosure: External dimensions of the front panel: The number of DIN rails/ length / the number of ,,S" fields: Distance of the TH35 DIN rail from the rear wall:
Possibility to mount additional equipment
Finish
Application
Net weight Gross weight

2x7Ah/12V 2x ­ opening and detachment of the enclosure from the
mounting surface 500mA@50Vdc IP 20 -10ºC÷40ºC 90 [%]
W=405, H=320, D+D1=90+14 [+/- 2mm] W1=412, H1=323 [+/- 2mm] 1 / 380 / 21 D2=18mm
Lock with a different code MR008
Electrolytic galvanized sheet DC01, 3µm zinc coating Corrosion protection:
Polyester paint, industrial use, color 7035 (grey)
Indoor/ surface-mounted
~ 4,35 [kg] ~ 4,75 [kg]

PRODUCENT / PRODUCER
Pulsar Siedlec 150, 32-744 Lapczyca, Poland Tel. (+ 48) 14-610-19-40, Fax. (+ 48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl
2



References

Microsoft Word 2010 3-Heights(TM) PDF Optimization Shell 5.9.1.5 (http://www -tools.com)