Installation Guide for SENECA models including: Z-TWS4-RT, Z-PASS1-RT, Z-TWS4-RT Z-PASS1-RT IoT Gateway, Z-TWS4-RT Z-PASS1-RT, IoT Gateway, Gateway
2 giorni fa — For use and settings via DIP-SWITCH SW1 see the user manual available on the website on the web page dedicated to the product. The DIP-switch settings are read ...
INSTALLATION MANUAL Z-TWS4-RT Z-PASS1-RT PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at risk. The word ATTENTION preceded by the symbol indicates conditions or actions that could damage the instrument or connected equipment. The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed. WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available using the QR-CODE shown on page 1. The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation. Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste. Z-TWS4-RT DOCUMENTATION Z-PASS1-RT DOCUMENTATION SENECA s.r.l.; Via Austria, 26 35127 PADOVA ITALY; Tel. +39.049.8705359 - Fax +39.049.8706287 CONTACT INFORMATION Technical support support@seneca.it Product information sales@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes. MI00611-3-EN INSTALLATION MANUAL 1/4 MODULE LAYOUT 35 mm USB 111 mm 102.5 mm LAN WAN Double module dimensions LxHxD: 35 x 102.5 x 111 mm; Weight: 175 g; Enclosure: PA6, black SIGNALS VIA LED ON FRONT PANEL LED PWR RUN DIDO1....DIDO6 VPN SRV RX1 / RX2 / RX4 TX1 / TX2 / TX4 ETH ACT (Green) ETH LNK (Yellow) STATUS On Off On Flashing Off On Off On Flashing On Flashing Off On Flashing Flashing Flashing On LED meaning Device powered correctly Device not powered Locking system The module is working correctly System Locked / Booting Input or output activated Input or output deactivated VPN connection active VPN connection problems VPN BOX "SERVICE" connection is working correctly VPN BOX "SERVICE" connection in error VPN BOX "SERVICE" connection disabled Incorrect RS485/ RS232 connection Reception of data packet completed on RS485/ RS232 Transmission of data packet completed on RS485/ RS232 Packet transit on Ethernet port Ethernet port connected TECHNICAL SPECIFICATIONS CERTIFICATIONS POWER SUPPLY ENVIRONMENTAL CONDITIONS ASSEMBLY CONNECTIONS PROCESSOR MEMORY FEATURES Z-TWS4-RT Z-PASS1-RT 11 ÷ 40Vdc; 50 ÷ 60Hz; Max absorption: 6 W Operating temperature: from -25°C to +65°C; Humidity: 10% ÷ 90% non condensing. Storage temperature: from -30°C to +80°C; Degree of protection: IP20 35mm DIN rail IEC EN60715 Removable 3.5 mm pitch terminal block, 1.5 mm2 max cable section ARM 32 bit 512MB RAM and 4GB Flash; PUSH-PUSH type slot for micro SD Integrated Web Server and update via Web Server MI00611-3-EN INSTALLATION MANUAL 2/4 COMMUNICATION PORTS COM1: RS232 / RS485 (on terminals) COM2: RS485 (on terminals or IDC10) COM4: RS485 (on terminals) Maximum baud rate 115kbps; minimum 200 bps Type A USB HOST ETH1 and ETH2 Fast Ethernet RJ45 10/100Mbps, Maximum connection distance: 100 m CAN (on terminals) or on IDC10 (with manual selector) (May not be present on all models). RS485 RS232 RS485 CAN INSULATION DI / DO Comm. ETH Intput LAN Output Comm. Analog Input Comm. ETH WAN USB Power Supply DIGITAL INPUTS OUTPUTS ANALOGUE INPUTS AUXILIARY VOLTAGE OUTPUT Number of inputs: 6 max.; Number of outputs: 6 max. Voltage OFF<4V, ON>8V MAX. current (Vout+) 50mA Absorbed current: 3mA @ 12Vdc , 5mA @ 24Vdc. Voltage (Vext+): 10 ÷ 28Vdc. MAX. current: 200 mA per channel Protect the outputs using a 1.5A fuse (as shown in the wiring diagrams) Voltage 0 ÷ 30Vdc, impedance 200k Current 0 ÷ 25 mA, impedance ~ 50 V AUX: 12Vdc; Max. 50 mA WARNING This is a Class A product. In a residential environment this equipment may cause radio interference. In this case, the user may have to take adequate countermeasures. INSTALLATION REGULATIONS The module has been designed for vertical installation on a DIN 46277 rail. For optimal operation and long life, adequate ventilation must be provided. Avoid positioning ducting or other objects that obstruct the ventilation slots. Avoid mounting modules over heat-generating equipment. Installation in the bottom part of the electrical panel is recommended. CAUTION These are open type devices intended for installation in a final casing/panel that offers mechanical protection and protection against the spread of fire. ModBUS CONNECTION RULES 1) Install the modules in the DIN rail (120 max) 2) Connect the remote modules using cables of an appropriate length. The following table shows cable length data: - Bus length: maximum length of the Modbus network according to the Baud Rate. This is the length of the cables that connect the two farthest modules. - Derivation length: maximum length of a derivation 2 m. For maximum performance, it is recommended to use special shielded cables, designed specifically for data communication. IDC10 CONNECTOR Power supply and Modbus interface are available also using the Seneca DIN rail bus, via the IDC10 rear connector, or the Z-PC-DINAL1-35. accessory. CAN GND / RS485 GND CAN H / RS485 A CAN L / RS485 B MI00611-3-EN Power supply DC + Power supply DC - IDC10 Back connector (IDC 10) The illustration shows the meanings of the various IDC10 connector pins if signals are to be sent via them directly. INSTALLATION MANUAL 3/4 ELECTRICAL CONNECTIONS CAUTION Switch the module off before connecting inputs and outputs. To meet the electromagnetic immunity requirements: - use shielded signal cables; - connect the shield to a preferential instrumentation earth system; - separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc.). POWER SUPPLY RS232 / RS485 COM1 RS485 COM2 RS485 COM4 CAN (Z-TWS4-RT) 29 5 Tx - RS232 13 A - RS485 21 A - RS485 21 30 6 Rx - RS232 14 B - RS485 22 B - RS485 22 31 7 A - RS485 15 GND 23 23 CAN L 32 8 B - RS485 16 24 24 CAN H 16 GND 29 GND 32 GND ANALOGUE INPUTS: VOLTAGE + V1 + V2 25 +V AUX 26 AI 1 27 AI 2 28 CAI ANALOGUE INPUTS: CURRENT mA 1 mA 2 25 +V AUX 26 AI 1 27 AI 2 28 CAI + V EXT DIGITAL INPUTS: 1- 3 FUSE: 1,5A 9 + V EXT 10 DI 1 11 DI 2 12 DI 3 CAI: COMMON ANALOG INPUT DIGITAL INPUTS: 4- 6 CAI: COMMON ANALOG INPUT DIGITAL OUTPUTS: 1- 3 CIO: COMMON I/O DIGITAL OUTPUTS: 4- 6 20 CIO FUSE: 1,5A CIO: COMMON I/O 9 + V EXT 17 DI 4 18 DI 5 19 DI 6 20 CIO + V EXT FUSE: 1,5A LOAD LOAD LOAD CIO: COMMON I/O 9 + V EXT 10 DO 1 11 DO 2 12 DO 3 20 CIO + V EXT FUSE: 1,5A LOAD LOAD LOAD CIO: COMMON I/O 9 + V EXT 17 DO 4 18 DO 5 19 DO 6 20 CIO SETTING THE DIP-SWITCHES WARNING The DIP-switch settings are read only at boot time. At each change, perform a restart. For use and settings via DIP-SWITCH SW1 see the user manual available on the website on the web page dedicated to the product. SW2 DIP SWITCH SETTING: (Z-TWS4-RT ONLY): Through DIP SWITCH SW2 it is possible to select RS485 or CAN communication through the IDC10 connector: SW2 KEY ON RS485 ACTIVATION ON ON OFF OFF CAN ACTIVATION OFF + V EXT MI00611-3-EN INSTALLATION MANUAL 4/4Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)