Instructions for starlab models including: SKU074A, SKU075A, SKU077A, SKU093A, SKU095A, SKU101A, HLD4L Laboratory Disinfectant, HLD4L, Laboratory Disinfectant, Disinfectant
Chemgene HLD4L Conc, Clear Unfragranced, 5 Litre
Chemgene MEDLAB Concentrate, Clear Unfragranced, 2 x 5 Litre
File Info : application/pdf, 1 Pages, 283.15KB
DocumentDocumentChemgene MEDLAB surface disinfectant. PIPETTE DECONTAMINATION PROCEDURE Recommended decontamination procedures for all models. Please note that these instructions are intended as a GUIDE ONLY and all pipettes requiring decontamination must be decontaminated according to your institution's own guidelines and the type of contaminant present. GENER AL DAILY CLE ANING/DECONTAMINATION 1:10 dilution is generally recommended, Spray or wipe handle and shaft (insuring the tip ejector button and volumeter are also cleaned) Leave for a minimum contact time of 10 minutes ORDERING INFORMATION 1 Litre Self-dosing Container Clear, Unfragranced 100% SKU074A 6 x 1 Litre 5 Litre Pump Container Clear, Unfragranced 100% SKU075A 2 x 5 Litres 5 Litre Pump Container Blue, Eucalyptus 100% SKU077A 2 x 5 Litres 750 ml Ready to Use Spray Clear, Unfragranced 10% SKU093A 6 x 750 ml 750 ml Ready to Use Spray Blue, Eucalyptus 10% SKU095A 6 x 750 ml 96-Wipe Resealable Flow Wrap 10% SKU101A 6 x 96-Wipes COMPLETE DECONTAMINATION Pipettes requiring full decontamination can be dismantled and cleaned: 1:10 dilution is generally recommended, Use a container that is deep enough to immerse the parts completely. (NOTE: Electronic pipettes must not be submerged in any liquids) Dismantle the pipette (as specified by the manufacturer) and place only parts that can be immersed, eg tip holder, piston, tip ejector etc completely into the solution for 30 minutes Remove parts and rinse with de-mineralised water Lie on a lint-free cloth and place in a dry oven at 60°C for at least one hour or until dry. Alternatively, place on the bench on a lint-free cloth and air dry for approximately 4 hours Reassemble the pipette following the manufacturer's instructions If complete decontamination is required prior to servicing, please ensure all parts are completely dry before reassembly and presenting for servicing NOTE: All pipettes for servicing must be accompanied by a completed Decontamination Declaration stating that the pipette is safe for us to work on, irrespective of whether the pipette required decontamination or not. DECONTAMINATION DECL ARATIONS W s tarlab.click /decontamination Product data sheet I Pipette decontamination