User Guide for EdgeMAX models including: ER-4, Edge Router, ER-4 Edge Router, Router
Ubiquiti Edge Router 4 ER-4 - KOA E.D.I.
2/10/22, 12:02 PM ER-4 Quick Start Guide https://dl.ui.com/qsg/ER-4/ER-4 EN.html 14/ 15 5IFSFBSFOPPQFSBUPSTFSWJDFBCMFQBSUTJOTJEFUIJTFRVJQNFOU ...
Index of /downloads
File Info : application/pdf, 15 Pages, 1.06MB
DocumentDocument2/10/22, 12:02 PM ER-4 Quick Start Guide ER-4 Quick Start Guide × Click for TP abalecokf C aognteenCtsontents EdgeRouter ER-4 Wall Mount Screws (Qty. 2) Wall Mount Anchors (Qty. 2) Power Cord Installation Requirements Drill with a 6 mm drill bit (for wall-mounting) Phillips screwdriver For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use. For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply. We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable WARNING: To reduce the risk of re or electric shock, do not expose the EdgeRouter to rain or moisture. Note: Although the cabling can be located outdoors, the EdgeRouter itself should be housed inside a protective enclosure. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 1/15 2/10/22, 12:02 PM ER-4 Quick Start Guide ER-4 Quick Start Guide × Click for TH aba lerod f Cw onatern etsOverview Note: The System LED functionality has been updated with rmware v1.10.7. We recommend that you update the EdgeRouter to the latest rmware. System LED Flashing White Bootup in progress. White Ready for use, not connected to Ubiquiti® Network Management System (UNMSTM). Blue Ready for use, connected to UNMS. Steady Blue with Occasional Flashing Ready for use, unable to connect to UNMS, check connection to UNMS server. Quickly Flashing Blue Used to locate a device in UNMS. Alternating Blue/White Firmware upgrade in progress. RJ45 Speed/Link/Act LED (0 - 2) Off No Link Amber Link Established at 10/100 Mbps Amber Flashing Link Activity at 10/100 Mbps Green Link Established at 1000 Mbps (1 Gbps) Green Flashing Link Activity at 1000 Mbps (1 Gbps) https://dl.ui.com/qsg/ER-4/ER-4_EN.html 2/15 2/10/22, 12:02 PM SFP Link/Act LED (3) Off × Click for Green Table of Contents Green Flashing Console ER-4 Quick Start Guide ER-4 Quick Start Guide No Link Link Established at 1 Gbps Link Activity at 1 Gbps RJ45 serial console port for Command Line Interface (CLI) management. USB Reserved for future use. RJ45 Ports (eth0 - eth2) RJ45 ports support 10/100/1000 Ethernet connections. SFP Port (eth3) SFP port is hot-swappable and supports Gigabit ber SFP modules. Reset Button Click here to learn how to reset an EdgeRouter to factory defaults. Hardware Installation WARNING: FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARD. KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW. Wall Mounting 1. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 3/15 2/10/22, 12:02 PM × Click for Table of Contents ER-4 Quick Start Guide ER-4 Quick Start Guide 2. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 4/15 2/10/22, 12:02 PM × Click for Table of Contents ER-4 Quick Start Guide ER-4 Quick Start Guide 3. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 5/15 2/10/22, 12:02 PM × Click for Table of Contents ER-4 Quick Start Guide ER-4 Quick Start Guide 4. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 6/15 2/10/22, 12:02 PM × Click for Table of Contents ER-4 Quick Start Guide ER-4 Quick Start Guide Grounding the EdgeRouter (Recommended) The Power Cord grounds the device; however, you can add optional ESD grounding for enhanced ESD protection. 1. Attach a screw (not included) to secure a ground wire (not included) to the Grounding Point. 2. Secure the other end of the ground wire to a grounding block. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 7/15 2/10/22, 12:02 PM ER-4 Quick Start Guide Connecting Power ER-4 Quick Start Guide Connect the Power Cord to the Power port and a power outlet. × Click for Table of Contents Using SFP Ports 1. 2. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 8/15 2/10/22, 12:02 PM × Click for Table of Contents ER-4 Quick Start Guide ER-4 Quick Start Guide 3. For information about compatible ber SFP modules, visit: ubnt.link/SFP_DAC_Compatibility Accessing the EdgeOS Con guration Interface The EdgeOS® con guration interface can be accessed via DHCP or static IP address assignment. By default, eth1 is set up as a DHCP client, while eth0 is assigned a static IP https://dl.ui.com/qsg/ER-4/ER-4_EN.html 9/15 2/10/22, 12:02 PM ER-4 Quick Start Guide address of 192.168.1.1. To con gure the EdgeRouter, proceed to the appropriate section: DHCP or "Static IP Address". ER-4 Quick Start Guide DHCP × Click for Ta1b. lC eoonfnCeocnttaenntEsthernet cable from eth1 on the EdgeRouter to a LAN segment that has an existing DHCP server. 2. To check the IP address of the EdgeRouter, use one of the following methods: Set up the DHCP server to provide a speci c IP address to the EdgeRouter based on its MAC address (on the label). Let the EdgeRouter obtain an IP address and then check the DHCP server to see which IP address was assigned. 3. Launch your web browser. Enter the appropriate IP address in the address eld. Press enter (PC) or return (Mac). 4. Enter ubnt in the Username and Password elds. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it. Click Login. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 10/15 2/10/22, 12:02 PM × Click for Table of Contents ER-4 Quick Start Guide ER-4 Quick Start Guide The EdgeOS Con guration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax Static IP Address 1. Connect an Ethernet cable from the Ethernet port on your computer to the port labeled eth0 on the EdgeRouter. 2. Con gure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 11/15 2/10/22, 12:02 PM ER-4 Quick Start Guide 3. Launch your web browser. Type https://192.168.1.1 in the address or return (Mac). ER-4 Quick Start Guide eld. Press enter (PC) 4. Enter ubnt in the Username and Password elds. Read the Ubiquiti License Agreement, and check the b×ox next to I agree to the terms of this License Agreement to accept it. Click for Click Login. Table of Contents The EdgeOS Con guration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax UNMS Management You can manage your device using UNMS, which lets you con gure, monitor, upgrade, and back up your devices using a single application. Get started at www.unms.com Speci cations Dimensions Weight Max. Power Consumption Power Method Power Supply Supported Voltage Range Button LEDs https://dl.ui.com/qsg/ER-4/ER-4_EN.html ER-4 229 x 136.5 x 31.1 mm (9.02 x 5.37 x 1.22") 795 g (1.75 lb) 13W Universal AC Power Cord (C13) Internal AC/DC Power Adapter, 30W DC 100-240VAC, 50/60 Hz Universal Adapter Reset 12/15 2/10/22, 12:02 PM Data Ports SFP Data Port × ProCcleicsk sofror Table of Contents System Memory On-Board Flash Storage ESD/EMP Protection Inter faces Management Networking Operating Temperature Operating Humidity Certi cations ER-4 Quick Start Guide ER-4 ER-4 Quick Start Guide Speed/Link/Activity Link/Activity 4-Core 1 GHz MIPS64 1 GB DDR3 RAM 4 GB eMMC, 8 MB SPI NOR Air: ± 24 kV, Contact: ± 24 kV (1) RJ45 Serial Port (4) Ethernet Ports (Default eth0) (3) 10/100/1000 RJ45 Ports (1) 1 Gbps SFP Port -10 to 50° C (14 to 122° F) 10 - 90% Noncondensing CE, FCC, IC Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories speci ed by the manufacturer. WARNING: Failure to provide proper ventilation may cause re hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate air ow. WARNING: To reduce the risk of re or electric shock, do not expose this product to rain or moisture. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer's label. Connection to a different power source than those speci ed may result in improper operation, damage to the equipment or pose a re hazard if the limitations are not followed. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 13/15 2/10/22, 12:02 PM ER-4 Quick Start Guide 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a quali ed service technician. ER-4 Quick Start Guide 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for conn×ection to a grounded safety outlet. Click for a. Do not substitute the power cord with one that is not the provided approved type. Never use an Table of Contents adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certi cation, modi cation or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a quali ed electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. Limited Warranty ui.com/support/warranty The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions. Compliance FCC Changes or modi cations not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. ISED Canada CAN ICES-3(A)/NMB-3(A) Australia and New Zealand https://dl.ui.com/qsg/ER-4/ER-4_EN.html 14/15 2/10/22, 12:02 PM ER-4 Quick Start Guide Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause raEdR io-4 intQ erufe icre knSctea. rt Guide × CECM licak rfo kring Table of Contents CE marking on this product represents the product is in compliance with all directives that are applicable to it. WEEE Compliance Statement Declaration of Conformity Online Resources © 2022 Ubiquiti Inc. All rights reserved. https://dl.ui.com/qsg/ER-4/ER-4_EN.html 15/15