Instruction Manual for PHILIPS models including: DUS804CS-UP, Multifunction Sensor, DUS804CS-UP Multifunction Sensor, Sensor
prieš 5 dienas — I dispositivi devono essere installati da un elettricista qualificato in conformità con le norme locali e nazionali vigenti in materia di costruzioni.
File Info : application/pdf, 2 Pages, 1.20MB
DocumentDocumentDUS804CS-UP Multifunction Sensor Installation Instructions Instructions d'installation Installationsanweisungen Instrucciones de instalación Istruzioni per l'installazione Installatie-instructies Devices must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. Les appareils doivent être installés par un électricien diplômé conformément à tous les codes et réglementations électriques et de construction nationaux et locaux. Die Geräte sind von einem qualifizierten Elektriker in Übereinstimmung mit allen geltenden Vorschriften zu installieren. Los dispositivos deben ser instalados por un electricista calificado y cumpliendo todas las normas y regulaciones, tanto nacionales como locales, sobre instalaciones eléctricas y obras. I dispositivi devono essere installati da un elettricista qualificato in conformità con le norme locali e nazionali vigenti in materia di costruzioni edilizie e installazione di impianti elettrici. De apparaten moeten worden aangebracht door een gekwalificeerde elektricien en in overeenstemming met alle nationale en plaatselijke elektriciteits- en bouwvoorschriften. / . 58 mm (2.28 in) 22 mm (0.86 in) 32 mm (1.25 in) 35 mm (1.38 in) 1 ULTRASONIC 2 ULTRASONIC > 2 m (6.5 ft) 90 mm (3.54 in) 90 mm (3.54 in) > 18 m (59.1 ft) 2.4 m (7.9 ft)* 2.1 - 4.0 m (6.9 - 13.1 ft) 8 m (26.2 ft)* (13.1 ft)* 4 m IEC Pollution Degree II 50° C (122° F) 0° C (32° F) 90% 12 m (39.3 ft)* 16 m (52.5 ft)* * 25° C (77° F) 3 A PIR 3B 120° IEC Pollution Degree II 5 PE 60° 5.5 m (18 ft)* 2.4 m (7 ft)* 2.1 - 4.0 m (6.9 - 13.1 ft) 4 PIR > 2 m (6.5 ft) ¡ 6 IR 700 m (23 ft)* * 25° C (77° F) 7 SELV/Class 2 (UL) 20 mm (0.79 in) RS-485 DyNet 2 A 12 V 80 mA IEC Overvoltage Category III 9 SHLD GND D+ D+12 V 0.3-2.5 mm2 22-12 AWG 0.4 Nm 3.5 Lb-in 10 8A 64 mm (2.52 in) 3 - 25 mm (0.12 - 0.98 in) 8B 30 mm (1.18 in) 51 mm (2.0 in) RS-485 DyNet Do not connect inputs to mains. Refer to Service Guide for full cleaning recommendations. Installation of a home and building automation and control system shall comply with IEC 60364 (all parts). The temperature limits and current-carrying capacities for the communication wires specified in IEC 60364-5-52 shall not be exceeded. © 2022 Signify Holding. All rights reserved. Specifications are subject to change without notice. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify Holding or their respective owners. www.dynalite.com AZZ 474 0922 R20