Owner's Manual for MEAN WELL models including: OWA-90E-12 Single Output Moistureproof Adaptor, OWA-90E-12, Single Output Moistureproof Adaptor, Output Moistureproof Adaptor, Moistureproof Adaptor
MEAN WELL Spannungsversorgungen | Arrow.de
OWA-90E-12 MEAN WELL USA Inc. - RADIOMAG GmbH
File Info : application/pdf, 5 Pages, 656.21KB
DocumentDocument90W Single Output Moistureproof Adaptor OWA-90E series User's Manual IP67 Bauar t gepruft Sicherheit egel ma ge od o s be wac g www.tuv.com ID 2000000000 Downloaded from Arrow.com. File Name:OWA-90E-SPEC 2023-09-19 90W Single Output Moistureproof Adaptor OWA-90E series SPECIFICATION MODEL OWA-90E-12 OWA-90E-15 OWA-90E-20 OWA-90E-24 OWA-90E-30 OWA-90E-36 OWA-90E-42 OWA-90E-48 OWA-90E-54 DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V RATED CURRENT 7.5A 6A 4.5A 3.75A 3A 2.5A 2.15A 1.88A 1.67A RATED POWER 90W 90W 90W 90W 90W 90W 90.3W 90.24W 90.18W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 ±4.0% ±4.0% ±4.0% ±3.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME Note.4 500ms, 80ms at 95% load 115VAC / 230VAC HOLD UP TIME (Typ.) 16ms at full load 115VAC / 230VAC VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.96/230VAC at full load INPUT EFFICIENCY (Typ.) 89% 90% 90% 90% 90% 91% 91% 91% 91% AC CURRENT (Typ.) 0.95A / 115VAC 0.5A / 230VAC INRUSH CURRENT (Typ.) COLD START 60A(twidth=550s measured at 50% Ipeak) at 230VAC LEAKAGE CURRENT <0.25mA / 240VAC OVERLOAD 105 ~ 115% Protection type : Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT PROTECTION OVER VOLTAGE Hiccup mode, recovers automatically after fault condition is removed 15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V Protection type : Shut down o/p voltage, re-power on to recover 46 ~ 54V 54 ~ 60V 59 ~ 66V OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. -40 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS EN61558-1,-2-16 listed; EN60335-1 listed(except for OWA-90E-42,48,54); EAC TP TC 004,IP67 approved SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMC EMISSION I/P-O/P:3.75KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN55014-1,EN61000-3-2,-3;EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55035, EN55014-2, light industry level (surge L- N : 2KV), EAC TP TC 020 MTBF 3044.3K hrs min. Telcordia SR-332 (Bellcore) 292.9K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 171*63*37.5mm NOTE PACKING 0.92Kg; 16pcs/15.7Kg/1.01CUFT Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:OWA-90E-SPEC 2023-09-19 90W Single Output Moistureproof Adaptor OWA-90E series Block Diagram EMI FILTER I/P & RECTIFIERS PFC CIRCUIT POWER SWITCHING O.T.P. O.L.P. PWM & PFC CONTROL RECTIFIERS & FILTER PFC fosc : 50~120KHz PWM fosc : 60~130KHz +V -V O.L.P. DETECTION CIRCUIT O.V.P. Derating Curve Static Characteristics 100 80 230VAC Input only 60 50 40 20 -40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz LOAD (%) LOAD (%) Downloaded from Arrow.com. File Name:OWA-90E-SPEC 2023-09-19 90W Single Output Moistureproof Adaptor OWA-90E series Mechanical Specification 171 1500±20 H05RN-F 1.0mm2×2C tc 85.5 5 5 2-4.5 tc : Max. Case Temperature CASE NO.: PWM-90P Unit:mm 5 5 300±20 H05RN-F 1.0mm 2 ×2C 32 4 1 3 63 31.5 37.5 Input Plug Type All standard models : CEE 7/7 Output Plug Assignment Model Category For standard model Plug Description XLR 4P, NEUTRIK NC4MX, or equivalent Plug Picture For optional model Lumberg 3611 03, or equivalent For optional model XLR 3P,NEUTRIK NC3MX, or equivalent For optional model CHOGORI 22002411-01 or equivalent For optional model Unicable UT-D170F4-2P or equivalent For optional model Unicable UT-D224-2P or equivalent For optional model 2.1 x 5.5 x 11 mm, center +, tuning fork type For details, please contact MEAN WELL. Outside 3 2 4 1 1 2 3 2 3 1 PIN NO. OUTPUT 1,2 +V 3,4 -V 1 +V 2 floated 3 -V 1 +V 2,3 -V 1 +V 12 2 -V 1 +V 1 2 2 -V 1 1 +V 2 2 -V Inside CENTER +V Downloaded from Arrow.com. File Name:OWA-90E-SPEC 2023-09-19 90W Single Output Moistureproof Adaptor Recommend Mounting Direction OWA-90E series Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:OWA-90E-SPEC 2023-09-19