This guide provides essential information for quickly setting up and operating the Seek FirePRO 300 thermal camera.
Getting Started: Device Controls
The Seek FirePRO 300 is designed for intuitive operation. Familiarize yourself with the primary controls:
- Power On/Off: Press and hold the power button for 2 seconds to turn the device on. A quick press and release will return the device to the default TI Basic mode. To power off, press and hold the power button for 3 seconds.
- Image and Video Capture: Press and release the capture button to take a still image. Press and hold the capture button for 2 seconds to begin video recording, and press and release again to stop recording.
- Temperature Unit (°F/°C): Press and release the dedicated button to toggle between Fahrenheit (°F) and Celsius (°C) temperature readings.
- Mode and Flashlight Control: Press and hold the mode button for 3 seconds to cycle through available imaging modes: TI Basic, TI Basic+, and Survey mode. Press and release this button to turn the integrated flashlight on or off.
Device Features and Visuals
The FirePRO 300 features a high-resolution thermal sensor and a bright LED flashlight. Key external features include:
-
Lanyard Attach Loop: A secure point for attaching a lanyard for portability and safety.
[Visual Description: A loop located at the top of the device for attaching a lanyard.]
-
300 Lumen Flashlight: A powerful integrated LED flashlight for illumination in low-light conditions.
[Visual Description: The flashlight is located on the top of the device.]
-
Dock Charging Contacts: Contacts on the bottom of the device for connecting to the charging dock.
[Visual Description: Four metallic contacts are visible on the base of the device, used for charging.]
-
320 x 240 Thermal Sensor: The primary sensor responsible for capturing thermal images.
[Visual Description: The main sensor window is located on the front of the device, below the screen.]
The device screen displays critical information:
-
On-Screen Device Icons:
- 1. Mode Indicator: Shows the current imaging mode (e.g., TI Basic+, Survey).
- 2. Overtemp Indicator: Alerts the user to temperatures exceeding a set threshold.
- 3. Spot Temperature Reticle: A crosshair indicating the point where temperature is being measured (active in TI Basic+ and Survey modes).
- 4. Battery Charge Status: Visual representation of the remaining battery life.
- 5. Spot Temperature Reading: Displays the measured temperature at the reticle's location (active in TI Basic+ and Survey modes).
- 6. Temperature Color Bar: A legend correlating colors in the thermal image to specific temperature ranges.
-
Battery Status Indicators:
- Green: Over 75% charge remaining.
- Yellow: Over 55% charge remaining.
- Orange: Over 25% charge remaining.
- Red: Less than 25% charge remaining (may flash if less than 5 minutes of operation remain).
[Visual Description: The device screen displays a thermal image with overlaid icons and readings. The image shows a scene with multiple individuals, with temperature readings like 1025, 850, 575, and 300 visible. A specific spot temperature of 135°F is also shown, along with a color bar indicating temperature ranges.]
Care and Support
Proper care ensures the longevity and performance of your Seek FirePRO 300:
- Cleaning Instructions: Clean the device's lenses and display using a lint-free cloth and a commercial lens cleaning solution. For the camera housing, use mild soap and warm water.
- Important Note: DO NOT USE SOLVENTS WHEN CLEANING THE PRODUCT.
For the most up-to-date specifications, support, and additional resources, please visit support.thermal.com.
[Visual Description: Two QR codes are displayed. The left one is labeled "User Manual" and the right one is labeled "Training".]