Installation Guide for SAVANT models including: QP1R60240, PUU-QP1R60240, PUUQP1R60240, QP1R60240 60 Amp Relay Companion Module with Current Transformer, QP1R60240, 60 Amp Relay Companion Module with Current Transformer
Savant Technologies LLC, dba GE Lighting, a Savant Company QP1R60240 QO 60A RELAYWITH CURENT TRANSFORMER PIGTAIL, QO 60A RELAYWITH CURENT TRANSFORMER PON PUU-QP1R60240 PUUQP1R60240 qp1r60240
File Info : application/pdf, 6 Pages, 1.36MB
DocumentDocumentProduct Information and Regulatory Statement Important Safety Information - Read First! Before installing, configuring, or operating any equipment, all relevant technical documentation must be read, understood, and followed. Savant technical documentation may contain important product-specific installation, mounting, and safety instructions, and can be accessed through the Savant Store. Scan the QR code or visit the URL below, enter the relevant product name or SKU in the Search Savant prompt, and select the product purchased to find documents, specifications and more. https://store.savant.com/DefaultStore/ccrz__HomePage Safety Statements All safety instructions below must be read, understood, and carefully followed under all applicable circumstances when working with any Savant equipment. 1. Follow all input power ratings marked on product near power input! 2. If fuse replacement is required, replacement fuse should match fuse rating marked on the product. 3. Do not use equipment near water. 4. Clean only with dry cloth. 5. Do not block any ventilation openings or install near any heat sources such as heat registers, stoves, radiators, amplifiers, etc. 6. Refer all servicing to qualified service personnel. Servicing is required when any part of the apparatus has been damaged in any way, or fails to operate normally for any reason. 7. Use only attachments/accessories specified by the manufacturer, following all relevant safety precautions for any such attachments/accessories. 8. For applicable equipment, use the included power cord with the grounding prong intact to insure proper grounding of the device. 9. If the provided plug does not fit the desired outlet, contact a licensed electrician to replace the obsolete outlet. 10. Protect any power cord from being walked on, pinched, strained, or otherwise potentially damaged, especially at the outlet or device connections. 11. Disconnect any outlet powered apparatus from its power source during lightning storms or when unused for long periods of time. 12. To completely disconnect equipment from AC mains power, disconnect the power supply cord plug from the AC receptacle on the device. 13. For any hardwired or fixed in-wall apparatus, carefully follow all wiring diagrams and instructions. All electrical wiring and servicing should be performed by a properly licensed electrician. Déclarations de Sécurité Toutes les instructions de sécurité ci-dessous doivent être lues, comprises et soigneusement suivies dans toutes les circonstances applicables lorsque vous travaillez avec un équipement Savant. 1. Suivez toutes les puissances nominales indiquées sur le produit près de la puissance absorbée! 2. Si le remplacement du fusible est nécessaire, le fusible de remplacement doit correspondre à la valeur nominale du fusible indiquée sur le produit. 3. N'utilisez pas d'équipement près de l'eau. 4. Nettoyer uniquement avec un chiffon sec. 5. Ne bloquez pas les ouvertures de ventilation et n'installez pas à proximité de sources de chaleur telles que les registres de chaleur, les cuisinières, les radiateurs, les amplificateurs, etc. 6. Confiez toutes les réparations à un technicien qualifié. Un entretien est requis lorsqu'une partie de l'appareil a été endommagée de quelque manière que ce soit ou ne fonctionne pas normalement pour une raison quelconque. 7. Utilisez uniquement les attachements / accessoires spécifiés par le fabricant, en suivant toutes les précautions de sécurité applicables à ces attachements / accessoires. 8. Pour l'équipement applicable, utilisez le cordon d'alimentation inclus avec la broche de mise à la terre intacte pour assurer une mise à la terre correcte de l'appareil. 9. Si la fiche fournie ne correspond pas à la prise souhaitée, contactez un électricien agréé pour remplacer la prise obsolète. 10. Protégez tout cordon d'alimentation contre les piétinements, les pincements, les tensions ou autres dommages potentiels, en particulier au niveau de la prise ou des connexions de l'appareil. 11. Débranchez tout appareil alimenté par une prise de courant de sa source d'alimentation pendant les orages ou lorsqu'il n'est pas utilisé pendant de longues périodes. 12. Pour déconnecter complètement l'équipement du secteur, débranchez la fiche du cordon d'alimentation de la prise secteur de l'appareil. 13. Pour tout appareil encastré ou câblé, suivez attentivement tous les schémas de câblage et les instructions. Tout le câblage électrique et l'entretien doivent être effectués par un électricien dûment agréé. IMPORTANT NOTES: · For product mounting, installation, safety instructions, technical specifications, and more, refer to the product Quick Reference Guide, available via the link or QR code noted above. · For regulatory and compliance information, see reverse of this sheet and/or product packaging. Savant Product Regulatory Statement | 009-1950-01 200707 | © 2020 Savant Systems, Inc. 1 of 2 45 Perseverance Way, Hyannis, MA 02601 Savant.com | 508.683.2500 FCC Regulations This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for CLASS B digital devices, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correcting the interference with one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect this equipment to an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement - Wireless and Handheld Devices Only This device meets the government's requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard for wireless devices employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg. *Tests for SAR are conducted using standard operating procedure accepted by the FCC with the device transmitting at its highest certified power level in all tested frequency bands. FCC and IC Identifier - Devices with Integrated Screen or User Interface Only This device electronically displays the FCC declaration of conformity logo as well as the FCC and IC identifier. This information can be found on the device by accessing: (Service menu) > About (A propos de) IC Statement This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-003. This device complies with RSS-310 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested built-in radios. The Country Code Selection feature is disabled for products marketed in the US/Canada. Déclaration IC Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1. L'appareil ne doit pas produire de brouillage, et 2. Cet appareil accepter toute interférence, y compris les interférences pouvant provoquer fonctionnement indésirable d'appareil. Déclaration d'exposition aux radiations Cet équipement est conforme aux limites d'exposition aux radiations de la FCC définies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. Identificateur de la FCC et d'Lc Ce périphérique par voie électronique affiche le logo de déclaration de conformité FCC ainsi que l'identificateur de la FCC et d'IC. Cette information peut être trouvée sur le terminal en accédant à: (Menu de service) > About (A propos de) Savant Product Regulatory Statement | 009-1950-01 200707 | © 2020 Savant Systems, Inc. 2 of 2 45 Perseverance Way, Hyannis, MA 02601 Savant.com | 508.683.2500 60 Amp Relay Companion Module with Current Transformer Quick Reference and Installation Guide Box Contents Descriptions (1) 240VAC (2 Pole) Relay Companion Module GPM-QP1R60240-21 QOTM w/Plug-on Neutral -or GPM-Q1R60240-21 QOTM w/Pigtail (1) Product Information and Regulatory Insert (009-1950) (1) Quick Reference and Installation Guide (this document) Specifications A B DPORNESSOCSTROENEN PAIR REMOINVSETAALFLTAETRION CIRCUIT POWER L1 L1 L2 2O4N0AGVUPT6MOM0-QAO1DRL2U6O-L0PAE2OD4INL0#INEP12PUE-RUT45ET2AAL31W2UA264TI0Y0GC0OV9:VCAM1A0uCAC7OT696II0N8NO0APHLHNUY-ZzTQEPQ1URLI6PO0MA2DE4N0OTUOTFUPCTUPCIUTNTIDD2O4:O0PRVUUAUSC-EQ6OP0N1AILRNY/P63U0HT2P4M0AX C YYWW L2 OUTPUT D Environmental E Temperature Humidity 32° to 104° F (0° to 40° C) 5% to 85% Relative Humidity (non-condensing) F Location Indoor Use Only Dimensions and Weights (net) Height Length Depth Weight Module (QO) 2.875 in. (7.30 cm) 5.00 in. 2.60 in. (12.70 cm) (6.61 cm) 1.0 lbs (.45 kg) A y Shipping 3.125 in. (7.94 cm) 7.25 in. 6.25 in. 1.25 lbs. (18.42 cm) (15.88 cm) (.57 kg) r Power Input Power (powers the module) 120V AC (+/- 10%) @ 60Hz, 0.1A (max) B a Input Power (from external source) Load Power 240V AC / 60A (max) 14400VA (240VAC 60A resistive load / 3HP max) C in Features of Automatic Action Type 1.B action Standards limD Wireless Bluetooth Low Energy (BLE) 2.4 GHz radio frequency IEEE 802.15.4 Regulatory E FCC Part 15 UL Safety and Emissions ICES 003 F Contains FCC ID: PUU-QP1R60240 e Contains IC: 10798A-QP1R60240 r RoHS Compliant Recommended Load Center Types P G All QOTM compatible modules fit into ¾ inch load centers. G Multi-Page LCD screen that can display the following: Power draw at the output. Firmware, Mac Address, and Regulatory Info. UID of the Host that the module is communicating with. Real-time Bluetooth status connectivity icon. Manual Load Switch - Toggle to the ON position to switch the load on. Toggle to AUTO for normal operation. PAIR Button - The PAIR button is a multi-use button. The duration that the button is pressed and held determines the function that gets initiated: Press and Release - Cycles through the various screens available on the LCD (POWER > INFO 1 > INFO 2). Press and hold - Press and hold for 2 seconds to put module into pairing mode. Press and hold for 5 seconds to reset. Input Power Connections - Connect outputs from a 2-pole breaker to inputs L1 and L2. See the Wiring section below. Output Power Connections - Connect a 240V AC load across outputs L1 and L2. See the Wiring section below. 120V AC Connection - Plugs into the 120V AC bus bar in the breaker panel. The voltage from this connection powers the companion module. Neutral - The model number of the module determines the type of neutral connection on the module: Plug-On Neutral - Positioned on the bottom of the module is a neutral clip that plugs directly onto the neutral bar. Pigtail Neutral - A neutral wire protrudes from the Supported Load Types module's rear and gets wired to the neutral bar in the Standard Relay On/Off type loads breaker panel. Configuration (home automation) Electrical and Safety Characteristics Screw Tighten Torque 5.0 Nm Wire Type Copper (Cu) only Pollution Degree 2 Purpose of Control Operating Control, Smart Relay Control Module or the equivalent Software Class A Impulse Voltage 2500V Construction of Control Open Type Independently mounted for flush mounting Supported Software Savant OS da Vinci 10.x Features Control capability for loads up to 14400VA (volt-ampere). All QOTM relay modules are compatible with Schneider Electric/ Square DTM QOTM load centers. Dynamic management of loads. Built-in energy monitoring; +/- .5% revenue grade accuracy / 1 sec sample time. Communicates with Panel Bridge Controller using Bluetooth Low Energy (BLE) technology. Manual load switches positioned on the front panel can toggle power to the output On and Off. Color LCD display for easy identification and load status. 60 Amp Relay Companion Module - QRG | 009-2103-00 Copyright© 2021 Savant Systems, Inc | 211230 1 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500 Important Information The breaker feeding this companion module should not be larger than 60 amps. This companion module can handle loads up to 60 amps. To determine the number of breaker panel spaces needed, add the number of spaces required for the circuit breakers with the spaces needed for the companion module. · Each 2-pole circuit breaker requires two spaces. · Each relay companion module requires four spaces. Each Panel Bridge Controller can communicate with up to 40 companion modules. Savant recommends not connecting any mission critical loads such as medical devices to this relay companion module. ELECTRIC SHOCK! The 120/240V AC, 60 Hz source poses an electrical shock hazard that has the potential to cause serious injury to installers and end users. Branch Circuit Minimum Size of Conductors (General circuit wiring, Copper Conductors) 15A 20A 30A 40A 50A 60A CAUTION! Risk of Electric Shock - More than one disconnect switch may be required to de-energize the device before servicing. #14 AWG #12 AWG #10 AWG #8 AWG #6 AWG #4 AWG NOTE: This wiring requirement was based on the National Electric Code IMPORTANT! A licensed electrician is required to install any of Savant's Relay Companion Modules. (NEC) (ANSI/NFPA70), Canadian Electric Code, Part 1 (CEC), and local codes Minimum Size of Conductors. Installation into Breaker Panel y 1. Remove power from the breaker panel by switching off the panel's main breaker. r 2. Position and install a 2-pole breaker into any two slots in the breaker panel. Press firmly until the breaker is fully seated onto the appropriate bus bars. 3. Position and install the 60 Amp Relay Companion Module into any four empty slots in the breaker panel. Press firmly until the a module is fully seated onto the appropriate bus bar. The companion module can be installed in any four open slots but is typically installed alongside the breaker installed in step 2. in HELPFUL! The companion module fills four slots in the breaker panel but connects to only one phase. The 120V AC from the breaker panel is used only to power the companion module. See diagrams below. 4. Use the diagrams below and make the appropriate connections. The diagram on the left is for companion modules that contain a plug-on neutral clip. The diagram on the right is for companion modules that include a neutral wire. lim Wiring with Plug-on Neutral Wiring with Pigtail Neutral Wire Pre NOTE: The companion module 60 Neutral Bar Companion Module with Plug-on Neutral 2-POLE BREAKER STAND BREAKER NOTE: 'he companion module 60 Neutral Bar Companion Module with Pigtail Wire for the Neutral 2-POLE BREAKER STAND BREAKER connects to just one phase. This 120V AC supplies power to the module. The 2-pole STAND BREAKER connects to just one phase. This 120V AC supplies power to the module. The 2-pole STAND BREAKER L1 breaker connects to both phases. L1 breaker connects to both phases. CIRCUIT POWER 240VAC 60A 2-POLE RELAY GPM-Q1R60240 ON AUTO MODULE INPUT 120VAC 60Hz LOAD INPUT 240VAC 60Hz LOAD OUTPUT 240VAC 60A INPUT OUTPUT INPUT OUTPUT L1 CIRCUIT POWER 240VAC 60A 2-POLE RELAY GPM-QP1R60240 ON AUTO MODULE INPUT 120VAC 60Hz LOAD INPUT 240VAC 60Hz LOAD OUTPUT 240VAC 60A INPUT OUTPUT INPUT OUTPUT L1 PAIR L2 PAIR L2 L2 L2 240V AC Load Plug-on neutral bar Phase B Phase A Breaker Panel 240V AC Load Phase B Phase A Breaker Panel 60 Amp Relay Companion Module - QRG | 009-2103-00 Copyright© 2021 Savant Systems, Inc | 211230 2 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500 Circuit Test Instructions Use the instructions below to test the relay companion modules. The setup requires: 60 Amp Relay Companion Module. Load with maximum amperage of 60A. Standard 2-pole, 60 amp circuit breaker. Breaker test panel. The type of companion module determines the type of breaker panel (plug-on neutral or not) 120/240V AC source IMPORTANT! The 2-Pole breaker connects across both phases in the breaker panel. The companion module, however, attaches to only one phase. This is shown in the image below. The GPM-Q160240-21 and GPM-QP160240-21 companion modules can accept up to a #4 AWG wire. See the Branch Circuit Minimum Size of Conductors table on the previous page. 1. Plug the 240V AC 2-Pole companion module and 60 amp 2-pole feeder breaker into the circuit breaker test panel. 2. Connect the output from one of the breakers on the 2-pole breaker to the L1 input on the companion module. 3. Connect the output from the remaining side of the 2-pole breaker to the L2 input on the companion module. 4. Connect one side of a load to the L1 output on the companion module. y 5. Connect the remaining side of the load to the L2 output on the companion module. r 6. On companion modules that contain a neutral wire, connect the neutral wire to the neutral bar. a 7. Apply power to the breaker panel (not shown in diagram) 8. Toggle the 60 amp 2-pole breaker to On. in 9. To test, toggle the CIRCUIT POWER switch on the companion module to the ON position and observe the load switches On. Toggle the CIRCUIT POWER switch to AUTO and verify the load switches Off. Neutral Bar The companion module connects to only one phase. The 2-Pole breaker connects to both phases 120V AC 240V AC Load 240VAC 60A 2-POLE RELAY GPM-Q1R60240 MODULE INPUT 120VAC 60Hz LOAD INPUT 240VAC 60Hz LOAD OUTPUT 240VAC 60A / 3HP ON AUTO PAIR 120V AC INPUT L2 OUTPUT L2 64 5 Connect the neutral wire to the neutral bar on companion modules that contain a neutral wire. OUTPUT L1 CIRCUIT POWER INPUT L1 1 23 standard 2-pole breaker 240V AC 60 8 9 Plug-on Neutral Bar lim Additional Documentation Further information is available in the documents listed below and can be accessed via the Savant Customer Community. Panel Bridge Controller - PoE (PBC-P1000) - QRG Pre Savant Panelized Lighting Deployment Guide. 60 Amp Relay Companion Module - QRG | 009-2103-00 Copyright© 2021 Savant Systems, Inc | 211230 3 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500 Notes Preliminary 60 Amp Relay Companion Module - QRG | 009-2103-00 Copyright© 2021 Savant Systems, Inc | 211230 4 of 4 45 Perseverance Way, Hyannis MA 02601 Savant.com | 508.683.2500Adobe Acrobat Pro 10.1.16 Adobe Acrobat Pro 10.1.16