Lennox C35 Indoor Coils
Upflow | Uncased Commercial Product Specifications (EHB)
Capacity Range: 1.5 to 5 Tons
Note: Coils sold in Canada for system installation and replacement. Coils sold in the US for repair/replacement only (no system installations allowed).
Model Number Identification
The model number follows a specific structure:
C 35 - [Nominal Cooling Capacity] [Coil Width] - [Metering Device] - [Minor Revision Number]
- Unit Type: C = Indoor Coil, Upflow
- Nominal Cooling Capacity: 18/24 (1.5/2 tons), 24 (2 tons), 30 (2.5 tons), 30/36 (2.5/3 tons), 36 (3 tons), 48 (3.5/4 tons), 49 (4 tons), 50/60 (4/5 tons), 60 (5 tons)
- Coil Width: A (14-1/2 in.), B (17-1/2 in.), C (21 in.), D (24-1/2 in.)
- Metering Device: 2 = Factory installed refrigerant metering device (RFC)
Note: Furnaces with the same letter designation physically match the indoor coil. Coils have different widths but will fit the corresponding furnace cabinet.
Approvals and Warranty
Approvals
- Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 210/240.
- AHRI Certified system match-ups and expanded ratings available at www.LennoxPros.com.
- Air resistance tests conducted by Lennox Laboratory air test chamber.
Warranty
- All other covered components:
- Limited five years in residential installations.
- Limited one year in non-residential installations.
Note: Refer to Lennox® Basic Limited Warranty at www.Lennox.com for additional details.
Features
Applications
- 1.5 to 5 ton nominal sizes.
- Lennox designed upflow indoor coils are easily installed with most Lennox upflow furnaces.
- Applicable to expansion valve or RFCIV systems.
- RFCIV metering device is factory installed. Note: RFCIV systems are applicable to certain air conditioners only.
- Expansion valve systems require a field-installed kit.
Coil Construction (Quantum™ Coil)
- Lennox designed and fabricated coil.
- Features aluminum tubing, hairpins, distributor, and header tubes.
- Ripple-edged aluminum fins enhance air stream contact.
- Lanced fins provide maximum exposure of fin surface to the air stream.
- Rifled tubing offers superior refrigerant heat transfer.
- Twin coil construction assembled in an "A" configuration for large surface area.
- Includes a liquid line seal nut section for expansion valve installation.
- High pressure testing ensures leak-proof construction.
Anti-Microbial Drain Pan
- Non-corrosive, UV-resistant polymer drain pan with dual FPT drain connections.
- Anti-Microbial additive resists mold and mildew growth, improving indoor air quality and reducing drain line blockage.
Universal Piping Patch Plate
- Shipped with the coil for field installation over the liquid and suction lines.
- Plate has a scored line for separation to accommodate different coil configurations.
Refrigerant Line Connections
- Copper refrigerant sweat connections on both liquid and suction lines for easy brazing.
- Refer to dimension drawings for specific locations.
Braze-Free/Press Fitting Flexibility
- Units can accommodate braze-free or press fittings for installation versatility.
Optional Accessories
- Expansion Valve Kits: Available for field installation. Refer to Air Conditioners or Heat Pump Outdoor Units Product Specifications for selection.
Furnace Match-Up
- Coils precisely match corresponding furnaces with the same letter designation in the model number, requiring no adapter.
- Engaging holes are provided for alignment.
- Coils fit furnaces without overhang, but may require an optional adapter base or field-fabricated transition to match the furnace opening.
Optional Accessories
- Adjustable Coil Adaptor/Seal: A telescoping adaptor for quick and easy installation of uncased coils to furnaces. Available in ten-pack kits. See dimension and application drawings for details.
Specifications
1.5 to 2 Ton Models
General Data | Model | Nominal size - Tons | Suction / vapor o.d. - sweat | Liquid o.d. - sweat | Condensate drain (fpt) | RFCIV metering device orifice size | Net face area sq. ft. | Tube diameter - in. | Number of rows | Fins per inch | Matching Lennox Furnace - Cabinet Width Designation | Coil & Furnace Cabinet Width - in. | Shipping Data - lbs. (Uncased) | Shipping Data - lbs. (Cased) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C35-18/24A-2 | 1.5/2 | 3/4 | 3/8 | (2) 3/4 | 0.053 | 3.11 | 3/8 | 2 | 18 | A | 14-1/2 | 18 | 30 | |
C35-18/24B-2 | 1.5/2 | 3/4 | 3/8 | (2) 3/4 | 0.053 | 3.11 | 3/8 | 2 | 18 | B | 17-1/2 | 20 | 34 | |
C35-24A-2 | 2 | 3/4 | 3/8 | (2) 3/4 | 0.057 | 3.55 | 3/8 | 3 | 14 | A | 14-1/2 | 23 | 38 | |
C35-24B-2 | 2 | 3/4 | 3/8 | (2) 3/4 | 0.057 | 3.55 | 3/8 | 3 | 14 | B | 17-1/2 | 24 | 43 |
2.5 to 3 Ton Models
General Data | Model | Nominal size - Tons | Suction / vapor o.d. - sweat | Liquid o.d. - sweat | Condensate drain (fpt) | RFCIV metering device orifice size | Net face area sq. ft. | Tube diameter - in. | Number of rows | Fins per inch | Matching Lennox Furnace - Cabinet Width Designation | Coil & Furnace Cabinet Width - in. | Shipping Data - lbs. (Uncased) | Shipping Data - lbs. (Cased) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C35-30A-2 | 2.5 | 3/4 | 3/8 | (2) 3/4 | 0.067 | 4.44 | 3/8 | 2 | 18 | A | 14-1/2 | 31 | 45 | |
C35-30B-2 | 2.5 | 3/4 | 3/8 | (2) 3/4 | 0.067 | 4.44 | 3/8 | 2 | 18 | B | 17-1/2 | 32 | 50 | |
C35-30/36A-2 | 2.5/3 | 3/4 | 3/8 | (2) 3/4 | 0.057 | 4.89 | 3/8 | 3 | 14 | A | 14-1/2 | 26 | 41 | |
C35-30/36B-2 | 2.5/3 | 3/4 | 3/8 | (2) 3/4 | 0.057 | 4.89 | 3/8 | 3 | 14 | B | 17-1/2 | 27 | 45 |
2.5 to 4 Ton Models
General Data | Model | Nominal size - Tons | Suction / vapor o.d. - sweat | Liquid o.d. - sweat | Condensate drain (fpt) | RFCIV metering device orifice size | Net face area sq. ft. | Tube diameter - in. | Number of rows | Fins per inch | Matching Lennox Furnace - Cabinet Width Designation | Coil & Furnace Cabinet Width - in. | Shipping Data - lbs. (Uncased) | Shipping Data - lbs. (Cased) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C35-30/36C-2 | 2.5/3 | 3/4 | 3/8 | (2) 3/4 | 0.057 | 4.89 | 3/8 | 3 | 14 | C | 21 | 29 | 48 | |
C35-36A-2 | 3 | 3/4 | 3/8 | (2) 3/4 | 0.070 | 4.89 | 3/8 | 2 | 18 | A | 14-1/2 | 31 | 46 | |
C35-36B-2 | 3 | 3/4 | 3/8 | (2) 3/4 | 0.070 | 4.89 | 3/8 | 2 | 18 | B | 17-1/2 | 33 | 50 | |
C35-48B-2 | 3.5/4 | 7/8 | 3/8 | (2) 3/4 | 0.071 | 5.77 | 3/8 | 3 | 14 | B | 17-1/2 | 43 | 55 | |
C35-48C-2 | 3.5/4 | 7/8 | 3/8 | (2) 3/4 | 0.071 | 5.77 | 3/8 | 3 | 14 | C | 21 | 44 | 60 |
4 to 5 Ton Models
General Data | Model | Nominal size - Tons | Suction / vapor o.d. - sweat | Liquid o.d. - sweat | Condensate drain (fpt) | RFCIV metering device orifice size | Net face area sq. ft. | Tube diameter - in. | Number of rows | Fins per inch | Matching Lennox Furnace - Cabinet Width Designation | Coil & Furnace Cabinet Width - in. | Shipping Data - lbs. (Uncased) | Shipping Data - lbs. (Cased) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C35-49C-2 | 4 | 7/8 | 3/8 | (2) 3/4 | 0.076 | 7.0 | 3/8 | 3 | 14 | C | 21 | 53 | 70 | |
C35-50/60C-2 | 4/5 | 7/8 | 3/8 | (2) 3/4 | 0.070 | 5.78 | 3/8 | 2 | 18 | C | 21 | 40 | 60 | |
C35-60C-2 | 5 | 7/8 | 3/8 | (2) 3/4 | 0.077 | 7.50 | 3/8 | 3 | 14 | C | 21 | 58 | 73 | |
C35-60D-2 | 5 | 7/8 | 3/8 | (2) 3/4 | 0.077 | 7.58 | 3/8 | 3 | 14 | D | 24-1/2 | 48 | 72 |
Note: Uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace width.
Air Resistance
Model No. | Air Volume (cfm) | Total Resistance (in. w.g.) | Model No. | Air Volume (cfm) | Total Resistance (in. w.g.) | ||
---|---|---|---|---|---|---|---|
Dry Coil | Wet Coil | Dry Coil | Wet Coil | ||||
C35-18/24A-2 | 400 | 0.06 | 0.08 | C35-36A-2 | 800 | 0.13 | 0.14 |
600 | 0.11 | 0.17 | 1000 | 0.19 | 0.21 | ||
800 | 0.18 | 0.25 | 1200 | 0.27 | 0.30 | ||
1000 | 0.27 | 0.39 | 1400 | 0.34 | 0.39 | ||
1200 | 0.37 | 0.52 | 1600 | 0.45 | 0.51 | ||
C35-24A-2 | 400 | 0.05 | 0.05 | C35-48B-2 | 1000 | 0.13 | 0.13 |
600 | 0.09 | 0.10 | 1200 | 0.18 | 0.18 | ||
800 | 0.16 | 0.18 | 1400 | 0.23 | 0.24 | ||
1000 | 0.23 | 0.26 | 1600 | 0.30 | 0.31 | ||
1200 | 0.32 | 0.36 | 1800 | 0.37 | 0.40 | ||
C35-24B-2 | 400 | 0.03 | 0.04 | C35-48C-2 | 1000 | 0.07 | 0.09 |
600 | 0.07 | 0.09 | 1200 | 0.10 | 0.12 | ||
800 | 0.11 | 0.15 | 1400 | 0.13 | 0.16 | ||
1000 | 0.17 | 0.22 | 1600 | 0.16 | 0.20 | ||
1200 | 0.23 | 0.31 | 1800 | 0.20 | 0.24 | ||
C35-30A-2 | 600 | 0.07 | 0.08 | C35-49C-2 | 1200 | 0.08 | 0.12 |
800 | 0.12 | 0.13 | 1400 | 0.13 | 0.17 | ||
1000 | 0.18 | 0.20 | 1600 | 0.17 | 0.22 | ||
1200 | 0.26 | 0.28 | 1800 | 0.22 | 0.28 | ||
1400 | 0.34 | 0.37 | 2000 | 0.28 | 0.35 | ||
C35-30B-2 | 600 | 0.06 | 0.06 | C35-50/60C-2 | 1200 | 0.13 | 0.17 |
800 | 0.09 | 0.11 | 1400 | 0.18 | 0.23 | ||
1000 | 0.13 | 0.16 | 1600 | 0.23 | 0.29 | ||
1200 | 0.19 | 0.23 | 1800 | 0.28 | 0.37 | ||
1400 | 0.25 | 0.31 | 2000 | 0.34 | 0.43 | ||
C35-30/36A-2 | 800 | 0.13 | 0.14 | C35-60D-2 | 1400 | 0.11 | 0.15 |
1000 | 0.19 | 0.21 | 1600 | 0.14 | 0.18 | ||
1200 | 0.27 | 0.30 | 1800 | 0.17 | 0.21 | ||
1400 | 0.34 | 0.39 | 2000 | 0.21 | 0.27 | ||
1600 | 0.45 | 0.51 | 2200 | 0.25 | 0.32 | ||
C35-30/36B-2 | 800 | 0.08 | 0.11 | 2400 | 0.30 | 0.37 | |
C35-30/36C-2 | 1000 | 0.13 | 0.16 | C35-60C-2 | 1400 | 0.15 | 0.19 |
C35-36B-2 | 1200 | 0.17 | 0.21 | 1600 | 0.19 | 0.23 | |
1400 | 0.22 | 0.28 | 1800 | 0.24 | 0.28 | ||
1600 | 0.29 | 0.34 | 2000 | 0.29 | 0.34 | ||
2200 | 0.33 | 0.40 | |||||
2400 | 0.39 | 0.46 |
Optional Accessories: Adjustable Uncased Coil Adaptor/Seal
This accessory is designed for uncased coils (C35-18/24A through C35-60C and C35-60D).
Installation Diagram Description:
Illustrates the placement of an uncased coil within a furnace system. Components shown include the PLENUM, ACCESS PANEL, UNCASED COIL, PIPING PATCH PLATE (furnished with coil), and FURNACE. The ADJUSTABLE COIL ADAPTOR/SEAL is positioned between the uncased coil and the furnace opening.
Adaptor/Seal Dimensions:
Front View: Shows the width adjustment range from 14-1/2 inches (368 mm) to 24-7/8 inches (632 mm). The opening height is 9 inches (228 mm) to 19-3/8 inches (492 mm). Other dimensions include 2-3/4 inches (70 mm) and 3/4 inches (19 mm).
Side View: Shows dimensions of 1 inch (25 mm) for thickness and 19-3/4 inches (502 mm) for length and 17-3/4 inches (451 mm) for opening length.
Adaptor/Seal Detail:
The frame telescopes to accommodate various furnace openings. A "Tab" is present, which may be bent up 90 degrees for centering smaller coils.
Dimensions
C35-18/24A, -18/24B, -24A, -24B Coils
Front View Description: Schematic of the coil's 'A' frame structure, indicating SUCTION LINE, LIQUID LINE, and CONDENSATE DRAINS with dimensions. Key labels include A, B, C, D, E, F, G.
Side View Description: Schematic showing the coil from the side, indicating AIR FLOW direction and dimensions related to cabinet opening and overall coil size. Key labels include D, E, F, G.
Model Number | A (in.) | B (in.) | C (in.) | D (in.) | E (in.) | F (in.) | G (in.) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | mm | mm | ||||||||
C35-18/24A | 13 | 330 | 14-1/8 | 359 | 9-1/4 | 235 | 1-1/4 | 32 | 5 | 127 | 3-1/8 | 79 | 3-7/8 | 98 |
C35-18/24B | 15-1/2 | 394 | 14-1/8 | 359 | 11-3/4 | 298 | 1 | 25 | 4-5/8 | 117 | 2-7/8 | 73 | 3-5/8 | 92 |
C35-24A | 13 | 330 | 16-3/8 | 416 | 9-1/4 | 235 | 2-7/8 | 73 | 7-5/8 | 194 | 3-1/8 | 79 | 3-3/4 | 95 |
C35-24B | 15-1/2 | 394 | 16-3/8 | 416 | 11-3/4 | 298 | 2-1/4 | 57 | 7-1/2 | 190 | 3-1/8 | 79 | 4 | 102 |
C35-30A Coil
Front View Description: Schematic of the C35-30A coil's 'A' frame structure, indicating SUCTION LINE, LIQUID LINE, and CONDENSATE DRAINS with dimensions. Key labels include A, B, C, D, E, F, G.
Side View Description: Schematic showing the C35-30A coil from the side, indicating AIR FLOW direction and dimensions related to cabinet opening and overall coil size. Key labels include D, E, F, G.
C35-30B, -30/36A, -30/36B, -30/36C, -36A, -36B, -48B, -48C, -50/60C Coils
Front View Description: Schematic of various C35 coils' 'A' frame structure, indicating SUCTION LINE, LIQUID LINE, and CONDENSATE DRAINS with dimensions. Key labels include A, B, C, D, E, F, G.
Side View Description: Schematic showing these C35 coils from the side, indicating AIR FLOW direction and dimensions related to cabinet opening and overall coil size. Key labels include D, E, F, G.
Model Number | A (in.) | B (in.) | C (in.) | D (in.) | E (in.) | F (in.) | G (in.) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | mm | mm | ||||||||
C35-30B | 15-1/2 | 394 | 20-3/4 | 527 | 11-3/4 | 298 | 3-1/8 | 79 | 8 | 203 | 3-1/8 | 79 | 4 | 102 |
C35-30/36A | 13 | 330 | 22-1/4 | 565 | 9-1/4 | 235 | 2-1/2 | 64 | 11-3/4 | 298 | 3-1/8 | 79 | 3-7/8 | 98 |
C35-30/36B | 15-1/2 | 394 | 22-1/4 | 565 | 11-3/4 | 298 | 2-5/8 | 67 | 11 | 279 | 3-1/8 | 79 | 4 | 102 |
C35-30/36C | 20 | 508 | 22-1/4 | 565 | 11-3/4 | 298 | 2-3/8 | 60 | 11-7/8 | 302 | 3-1/8 | 79 | 4 | 102 |
C35-36A | 13 | 330 | 22-3/8 | 568 | 9-1/4 | 235 | 4-1/4 | 108 | 12-5/8 | 321 | 2-1/2 | 64 | 3-1/2 | 89 |
C35-36B | 15-1/2 | 394 | 22-3/8 | 568 | 11-3/4 | 298 | 4-3/8 | 111 | 13 | 330 | 2-7/8 | 73 | 3-5/8 | 92 |
C35-48B | 15-1/2 | 394 | 26-1/4 | 667 | 11-3/4 | 298 | 4-3/8 | 111 | 12-1/4 | 311 | 3-1/8 | 79 | 3-3/4 | 95 |
C35-48C | 20 | 508 | 26-1/4 | 667 | 16-1/4 | 413 | 4-1/8 | 105 | 11-3/4 | 298 | 3-1/8 | 79 | 3-3/4 | 95 |
C35-50/60C | 20 | 508 | 25-7/8 | 657 | 16-1/4 | 413 | 3-3/4 | 95 | 11-3/4 | 298 | 3-1/8 | 79 | 4 | 102 |
C35-49C Coil
Front View Description: Schematic of the C35-49C coil's 'A' frame structure, indicating SUCTION LINE, LIQUID LINE, and CONDENSATE DRAINS with dimensions. Key labels include A, B, C, D, E, F, G.
Side View Description: Schematic showing the C35-49C coil from the side, indicating AIR FLOW direction and dimensions related to cabinet opening and overall coil size. Key labels include D, E, F, G.
C35-60C Coil
Front View Description: Schematic of the C35-60C coil's 'A' frame structure, indicating SUCTION LINE, LIQUID LINE, and CONDENSATE DRAINS with dimensions. Key labels include A, B, C, D, E, F, G.
Side View Description: Schematic showing the C35-60C coil from the side, indicating AIR FLOW direction and dimensions related to cabinet opening and overall coil size. Key labels include D, E, F, G.
C35-60D Coil
Front View Description: Schematic of the C35-60D coil's 'A' frame structure, indicating SUCTION LINE, LIQUID LINE, and CONDENSATE DRAINS with dimensions. Key labels include A, B, C, D, E, F, G.
Side View Description: Schematic showing the C35-60D coil from the side, indicating AIR FLOW direction and dimensions related to cabinet opening and overall coil size. Key labels include D, E, F, G.
Dimensions - Furnace/Coil Combined Dimensions (Upflow Position)
Model No | C35 | A (in.) | B (in.) | ||
---|---|---|---|---|---|
mm | mm | mm | |||
C35-18/24A | C35 Uncased | 14-1/8 | 359 | 47-1/8 | 1197 |
C35-18/24B | 14-1/8 | 359 | 47-1/8 | 1197 | |
C35-24A | 16-3/8 | 416 | 49-3/8 | 1254 | |
C35-24B | 16-3/8 | 416 | 49-3/8 | 1254 | |
C35-30A | 20-3/4 | 527 | 53-3/4 | 1365 | |
C35-30B | 20-3/4 | 527 | 53-3/4 | 1365 | |
C35-30/36A | 22-1/4 | 565 | 55-1/4 | 1403 | |
C35-30/36B | 22-1/4 | 565 | 55-1/4 | 1403 | |
C35-30/36C | 22-1/4 | 565 | 55-1/4 | 1403 | |
C35-36A | 22-3/8 | 568 | 55-3/8 | 1407 | |
C35-36B | 22-3/8 | 568 | 55-3/8 | 1407 | |
C35-48B | 26-1/4 | 667 | 59-1/4 | 1505 | |
C35-48C | 28-1/2 | 724 | 61-1/2 | 1562 | |
C35-49C | 25-7/8 | 657 | 58-7/8 | 1495 | |
C35-50/60C | 30-5/8 | 778 | 63-5/8 | 1616 | |
C35-60C | 28 | 711 | 61 | 1549 | |
C35-60D | 28 | 711 | 61 | 1549 |
Diagram shows a furnace with dimensions A and B labeled for combined unit height.