Fieldpiece SRS1 Refrigerant Scale with Weight Alarm
OPERATOR'S MANUAL
Model SRS1
Quick Start
- Install the 9V battery into the controller.
- Place the platform on solid, level ground for best accuracy.
- Press ON/OFF for 1 second to turn on the scale.
- Press UNITS for 1 second to switch between LB, LB OZ, OZ and KG.
- Press ZERO for 1 second to tare the scale.
- Read weight directly on the display.
Certifications
CE
WEEE
RoHS Compliant
Description
The Fieldpiece SRS1 refrigerant scale is designed for charging and recovery. It features a thick aluminum construction for accuracy and durability. The controller can be hung on a condenser for easy viewing, and its magnetized back keeps it in place. The scale has a backlight for low-light conditions and rubber feet for stability. It allows for quick setting of charge/recover alarms and features a keypad for easy input. The scale is designed for ease of use in HVACR applications.
Specifications
Specifications are good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity.
- Over range: "OL" is displayed and beep sounds.
- Maximum load: 110 lbs (50kg).
- Auto power off: 30 minutes of inactivity (APO disabled in charge/recover mode).
- Backlight: Blue, turns off in 60 seconds if no buttons are pressed.
- Accuracy: ±(0.05%rdg + 10g).
- Resolution and Units: LB OZ (1 LB, 0.25 OZ), LB (0.02 LB), OZ (0.25 OZ), KG (0.01 KG).
- Temperature coefficient: 0.1 x (specified accuracy) per °F.
- Battery: 9V, NEDA 1604, JIS 006P, IEC 6F22.
- Battery life: 80 hours typical alkaline (without backlight).
- Low battery indication: ? is displayed when the battery voltage drops below the operating level.
- Operating environment: 32°F to 122°F (0°C to 50°C) at <75% RH.
- Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed).
- Weight: 6.6 lbs (3.00 kg).
Maintenance
Clean the exterior with a dry cloth. Do not use liquid.
Replace the battery when the battery life indicator is empty. Remove the rear battery cover and replace with a 9V battery.
Limited Warranty
This meter is warranted against defects in material or workmanship for one year from date of purchase from an authorized Fieldpiece dealer. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss. State laws vary. The above limitations or exclusions may not apply to you.
Obtaining Service
Email Fieldpiece warranty department at fpwarranty@fieldpiece.com for current fixed price repair service. Send check or money order made out to Fieldpiece Instruments for the amount quoted. If your meter is under warranty there will be no cost for the repair/replacement. Send your scale, freight prepaid, to Fieldpiece Instruments. Send proof of date and location of purchase for in-warranty service. The meter will be repaired or replaced, at the option of Fieldpiece, and returned via least cost transportation.
For international customers, warranty for products purchased outside of the U.S. should be handled through local distributors. Visit the Fieldpiece website to find your local distributor: www.fieldpiece.com
©Fieldpiece Instruments, Inc 2015; v08
Functions
Weight Measurement
The SRS1 scale is designed to measure refrigerant tanks weighing up to 110 lbs. Note: Placing items over 110 lbs on the scale may damage the scale.
- Remove the scale from the padded case and place the platform on solid, level ground.
- Press ON/OFF for 1 second to turn on the scale.
- Press UNITS for 1 second to switch between LB, LB OZ, OZ and KG.
- Press ZERO for 1 second to zero (tare) the scale.
- Set your tank on the platform and zero again to view only the change in refrigerant.
- View the change in weight in real-time when charging or recovering refrigerant.
Backlight
Press LIGHT to turn on the blue backlight on the LCD. This is useful when the sun is going down on late day jobs or any dark situation. The backlight uses extra battery power than standard use.
Weight Alarm
You can set the alarm to sound when approaching a set weight. This is useful when you know how much you want to add or remove from the system and you want to work on other things nearby. It is best to do a practice run before using on a job so you know how it works.
- Set the tank on the platform.
- Select desired units.
- Press CHARGE or RECOVER.
- Use the number keys to enter how much refrigerant you want to add (charge) or remove (recover). If in LB OZ mode, press ENTER to move to OZ.
- Press ENTER.
- The display will now show 0.0 and you can begin charging or recovering.
- The alarm will sound when the weight gets close to the weight you entered, so you know when to close the valve.
- Press ENTER/EXIT to exit CHARGE/RECOVER mode.
- Press REPEAT to automatically set the alarm to the last entered weight.
Tech Tips
Respect the Environment
Always use hoses with ball valves or low-loss fittings to minimize harmful refrigerant gases entering the atmosphere.
Account for Your Hose Weight
Connect the hoses to the system and tank before zeroing the scale. After charge/recovery is finished and the system is stable, note the weight before removing hoses.
Other Great Tools
Fieldpiece offers a range of other tools for HVACR professionals:
- Digital Manifolds
- Leak Detectors
- Clamp Meters
Related Documents
![]() |
Fieldpiece SRS1 Lightweight Refrigerant Scale for HVACR Professionals Discover the Fieldpiece SRS1, a lightweight and durable refrigerant scale designed for residential and light commercial HVACR applications. Features include heavy-duty construction, charging/recovery alarms, and a user-friendly numeric keypad. |
![]() |
Fieldpiece SR47 Wireless Refrigerant Scale Operator's Manual & Quick Start Guide Comprehensive operator's manual and quick start guide for the Fieldpiece SR47 Wireless Refrigerant Scale, detailing features, specifications, functions, maintenance, and troubleshooting. |
![]() |
Fieldpiece SMAN® Refrigerant Manifold Operator's Manual Operator's manual for the Fieldpiece SMAN® Refrigerant Manifold with Built-in Vacuum Gauge (Models SM382V and SM482V), detailing features, operation, specifications, and maintenance for HVACR professionals. |
![]() |
Fieldpiece DR82 Infrared Refrigerant Leak Detector Operator's Manual Operator's manual for the Fieldpiece DR82 Infrared Refrigerant Leak Detector. This document provides detailed information on the product's description, features, specifications, operation, maintenance, and functionality testing. It also includes warnings and warranty information. |
![]() |
Fieldpiece DR82 Infrared Refrigerant Leak Detector Operator's Manual Comprehensive guide to the Fieldpiece DR82 Infrared Refrigerant Leak Detector, covering its features, specifications, operation, maintenance, and warranty. Learn how to detect HFC, HCFC, CFC, HFO, and blend refrigerants with high sensitivity and multiple indicators. |
![]() |
Fieldpiece DR82 Infrared Refrigerant Leak Detector Operator's Manual Operator's manual for the Fieldpiece DR82 Infrared (IR) Refrigerant Leak Detector. Details features, specifications, operation, maintenance, safety guidelines, and warranty information for HVACR professionals. |
![]() |
Fieldpiece DR82 Infrared Refrigerant Leak Detector Operator's Manual Comprehensive operator's manual for the Fieldpiece DR82 Infrared (IR) Refrigerant Leak Detector, detailing its features, operation, maintenance, and specifications for HVACR professionals. |
![]() |
Fieldpiece MG44 Wireless Vacuum Gauge Operator's Manual Operator's manual for the Fieldpiece MG44 Wireless Vacuum Gauge, detailing its features, operation, maintenance, and specifications for HVACR professionals. |