SonicWall TZ270/TZ370/TZ470 Series Safety, Regulatory, and Legal Information
This document provides safety, regulatory, and legal information for the SonicWall TZ270, TZ270W, TZ370, TZ370W, TZ470, and TZ470W network security appliances.
Installing the Appliance
WARNING: The following conditions are required for proper installation.
- Install in a location away from direct sunlight and sources of heat. A maximum ambient temperature of 104° F (40° C) is recommended.
- Route cables away from power lines, fluorescent lighting fixtures, and sources of noise such as radios, transmitters, and broadband amplifiers.
- The included power cord(s) are approved for use only in specific countries or regions. Before using a power cord, verify that it is rated and approved for use in your location.
- Ensure that no water or excessive moisture can enter the unit.
- Allow unrestricted airflow around the unit and through the vents on the side of the unit. A minimum of 1 inch (25.44mm) clearance is recommended.
- When wall mounting, use two #6 (3M) by 1 inch (25mm) long pan-head (7mm) screws.
- Consideration must be given to the connection of the equipment to the supply circuit. Appropriate consideration of equipment nameplate ratings must be used when addressing this concern. Do not overload the circuit.
- Reliable grounding of power supply must be maintained. Particular attention must be given to power supply connections other than direct connections to the branch circuits, such as power strips.
- When using a Fiber Optic Small-Form Pluggable (SFP) module, ensure it is IEC 60825 certified and a Class 1 Laser Product.
- This equipment is not intended for use at workplaces with visual display units, in accordance with §2 of the German ordinance for workplaces with visual display units. To avoid incommoding reflections at visual display workplaces this device must not be placed in the direct field of view.
Lithium Battery Warning
The Lithium Battery used in the SonicWall security appliance may not be replaced by the user. Return the SonicWall security appliance to a SonicWall-authorized service center for replacement with the same or equivalent type recommended by the manufacturer. If, for any reason, the battery or SonicWall security appliance must be disposed of, do so following the battery manufacturer's instructions.
Cable Connections
All Ethernet and RS232 (Console) cables are designed for intra-building connection to other equipment. Do not connect these ports directly to communication wiring or other wiring that exits the building where the SonicWall appliance is located.
Power Supply Information
If the power supply is missing from your SonicWall product package, please contact SonicWall Technical Support at https://www.sonicwall.com/support/contact-support for a replacement. This product should only be used with a UL listed power supply marked "I.T.E. LPS" with an output rated 12V DC, minimum 3.0 A, Tma: minimum 40 degree C.
A redundant power adapter is not provided with the product, but can be ordered separately.
NOTE: Additional regulatory notifications and information for this product can be found online at: https://www.sonicwall.com/support.
Warranty Information
All SonicWall appliances come with a 1-year Limited Hardware Warranty which provides delivery of critical replacement parts for defective parts under warranty. Visit the Warranty Information page for details on your product's warranty at https://www.sonicwall.com/support.
Declarations of Conformity
Simplified EU/CE Declaration of Conformity - TZ270W/TZ370W/TZ470W
Hereby, SonicWall Inc. declares that the radio equipment type 2.4 GHz and 5 GHz RLAN/WLAN is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following Internet address: https://www.sonicwall.com/support.
This SonicWall appliance contains radio equipment to provide 2.4 GHz and 5 GHz RLAN/WLAN. To maintain Radio Equipment Directive 2014/53/EU compliance, use only SonicOS software and accessories provided with this appliance and by SonicWall.
To maintain safe exposure levels to electromagnetic fields, place appliance a minimum of 20 cm from all persons and domestic animals.
This SonicWall wireless appliance is restricted to indoor use.
United Kingdom
SonicWall (UK) Limited, Matrix House, Basing View, Basingstoke, Berkshire, UK.
Serial Number: COEAE4123456
EU and EFTA Declarations of Conformity
A "Declaration of Conformity" in accordance with the directives and standards has been made and is on file at: SonicWall International Limited, City Gate Park, Mahon, Cork, Ireland. CE declarations can be found online at https://www.sonicwall.com/support.
Anatel (Brazil)
This product is approved by Anatel, in accordance with the procedures regulated by Resolution No. 715/2019 and meets the technical requirements applied.
For more information, consult the ANATEL website - http://www.anatel.gov.br.
This equipment operates on a secondary basis, meaning it is not entitled to protection against harmful interference, even from systems of the same type, and cannot cause interference to systems operating on a primary basis.
Taiwan RoHS
Information on the content of restricted substances can be found at the following URL: https://www.sonicwall.com/support.
Product Name: Network Security Appliance (TZ270/TZ370/TZ470), Wireless Network Security Appliance (TZ270W/TZ370W/TZ470W)
Model Numbers: TZ270/TZ370 (APL57-100), TZ270W/TZ370W (APL57-101), TZ470 (APL57-0F1), TZ470W (APL57-0F2)
Rated Voltage (DC Adapter): 12Vdc
Rated Input Current (DC Adapter): 3.0A
Year of Manufacture: Refer to the first two digits of the manufacturing date number on the product label and outer box. For example, S-15039 indicates the year of manufacture is 2015.
Manufacturing Number: Refer to the product serial number on the product label and outer box. For example, C0EAE4123456.
Country of Origin: Made in Taiwan
Operating Instructions: Refer to the Safety Information Installation and Operation Manual.
Safety Information and Regulatory Information
Radio Frequency Transmitter Bands and Power
Frequency Band (MHz) | Maximum RF Power Transmitted dBm EIRP |
---|---|
TZ270W/TZ370W/TZ470W | |
2412-2472 | 19.76 |
5180-5240 | 22.63 |
5260-5320 | 22.43 |
5500-5700 | 29.38 |