FV830
AquaSense®
ZER-SM Series Automatic Battery-Powered Flush Valve Retrofit Kit
Installation, Operation, Maintenance and Parts Manual
ZERK-SM
LIMITED WARRANTY
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are "consumer products," the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are approximate and are not guaranteed. ! WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ! ADVERTENCIA: Cáncer y Daño Reproductivo - www.P65Warnings.ca.gov ! AVERTISSEMENT: Cancer et effet nocif sur la reproduction - www.P65Warnings.ca.gov
Rev. B | Date: 05/01/23 | C.N. No. 145289 | Prod./Dwg. No. FV830 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216
ZURN.COM

Specifications
Sensor Range: 12" to 60" (adjustable) Power Type: Battery powered; 4x C size
Operating Water Pressure: 25 psi [172 kPa] (Running); 80 Psi [552 kPa] Max (Static)
Operating Temperature: 35°F to 104°F [2°C to 40°C]

Prior to Installation
· Before installing your flush valve, the items listed below should already be installed on-site: - Water closet or urinal fixture - Fixture carrier - Drain line - Water supply line

Important Safety Information

Package Contents

· Do not convert or modify this Zurn product. All warranties will be voided.
· All plumbing is to be installed in accordance with applicable codes and regulations.
· Water supply lines must be sized to provide an adequate volume of water for each fixture.
· Flush all water lines prior to making connections.
· Do not use pipe sealant or plumbing grease on any fitting other than the control stop inlet.
· Sensor units should not be located across from each other or in close proximity to highly reflective surfaces.
· Control stop should never be opened to allow flow greater than fixture is capable of evacuating. In the event of valve failure, fixture must be able to handle a continuous flow.

E-Z Flush®

E-Z Flush Retrofit Installation

Shut off water supply at stop.
1. Shut off water supply at stop.
2. Using the supplied wrench, loosen handle nut.
3. Remove handle and its valve gasket from flush valve. Note: A small amount of water may drip from the port.
4. Place the supplied valve gasket onto the unit as shown. Use one hand to raise the unit to the handle port of the flush valve and use the other hand to rotate the unit's valve nut to begin engaging the threads of the valve body.
5. Use the supplied wrench to tighten the E-Z Flush unit securely to the valve body.
6. Turn on water at the stop valve.
Note: Save handle in the event you wish to reuse for service of E-Z Flush

Valve Nut Valve Gasket

Hex Key and Valve Gasket

FV830 Rev. B 05/01/23 Page 1

E-Z Flush Wrench

E-Z Flush Activation
Using supplied hex key, remove battery compartment from the E-Z Flush unit. Load the supplied batteries into the battery tray. Note the battery orientation shown. Reinstall the battery tray into the E-Z Flush unit using the hex key. The user LED will blink when the unit becomes powered.

Notes:
Your E-Z Flush unit comes preset from the factory. If special circumstances require adjustment of the activation distance, see section of this manual "Adjusting Calibration Distance". Each E-Z Flush comes with a 24-hour flush mode that is disabled by default. To toggle this mode, see the section of this manual entitled "Toggling 24-Hour Flush Mode".
Adjusting Calibration Distance
Each E-Z Flush comes calibrated from the factory to work optimally in most restroom environments. In low light or highly reflective environments however, it may be necessary to adjust the calibration distance of an E-Z Flush unit. To do this, a Zurn Magic Magnet may be used. To re-calibrate an E-Z Flush with a Magic Magnet, follow the procedure below: comes calibrated from the factory. To re-calibrate for a specific environment, follow these steps: 1. Stand at the desired calibration distance:
- ~28" from the sensor in a water closet application. - ~22" from the sensor in a urinal application. 2. Raise the Magic Magnet to the top/bottom (depending on valve orientation - refer to image below) of the unit's lens until the user LED lights up. 3. Hold the Magic Magnet in that position until the user LED begins to blink. Remove the magnet and allow the user LED to blink 10 times while standing in the same position. A quick double-blink signals that the calibration is complete. 4. Test the new calibration distance by walking away from the unit for 5 seconds and returning to the position at which it was calibrated. Watch for the user LED to blink. If the user LED blinks, the calibration distance has been reset successfully.

Note: In water closet applications, it is a good idea to make sure that the new calibration distance does not allow the sensor to see the stall door. To check this, exit the stall and close the stall door for 10 seconds. Open the stall door. If the unit does not flush, the calibration distance is okay. If the unit flushes, you will need to recalibrate to a closer distance.

Magic Magnet position for LEFT hand install

Magic Magnet position for RIGHT hand install

Status LED

Status LED
Optional Accessary Magic Magnet P6900-AT-MAG

FV830 Rev. B 05/01/23 Page 2

Toggling 24-Hour Flush Mode
Each E-Z Flush comes with a 24-hour auto-flush feature that is disabled by default. This feature is intended for low-use applications where trap seal depletion is a concern. To toggle this feature, follow the procedure below: 1. Raise a Magic Magnet to the top/bottom (depending on valve orientation - refer to image on previous page) until the user LED
lights up. 2. Lower the magnet so that the user LED turns off. 3. Repeat this turn on / turn off procedure three more times. 4. After the fourth time, the user LED will display a series of rapid blinks. Three blinks signifies that the feature has been toggled on.
Six blinks signifies that the feature has been toggled off.
Flush Valve Trouble Shooting Guide

PROBLEM User LED continuously blinks every five seconds. Insufficient flow of water. Excessive flow of water. Continuous flow of water.
User LED does not blink when user is present.

CAUSE Low battery life.

SOLUTION Replace batteries.

Stop Valve improperly adjusted.
Stop Valve improperly adjusted.
Debris clogging flush valve's diaphragm.
Calibration distance is set too short. Confirm by placing hand 6" in front of the sensor and watching for a blink. If the user blinks, the calibration is set too short.
Batteries are dead. Confirm by placing hand 6" in front of the sensor and watching for a blink. If the user LED does not blink, the batteries are dead.

Adjust stop valve (open). Adjust stop valve (close). Replace diaphragm kit (See section entitled "Repair Parts"). Reset calibration to desired distance (See section entitled "Adjusting Calibration Distance").
Replace batteries.

FV830 Rev. B 05/01/23 Page 3

Rev. B | Date: 05/01/23 | C.N. No. 145289 | Prod./Dwg. No. FV830