User Manual for PPI models including: LabCon Recording 4 Channel Mapping Printer Interface, LabCon, Recording 4 Channel Mapping Printer Interface, 4 Channel Mapping Printer Interface, Mapping Printer Interface, Printer Interface, Interface
Temperature control system | Temperature Recorders India - PPI controller
File Info : application/pdf, 2 Pages, 437.69KB
DocumentDocumentLabCon (MAP + Printer) Recording + 4 Channel Mapping + Printer Interface Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net OPERATOR PAGE PARAMETERS Parameters Settings (Default Value) Select Print Option>> None Print (New) Re-Print (Old) Print Info Page (Default : None) Time Start Command >> Time Abort Command >> Time Interval (H:M) >> Yes No (Default : No) 0.00 to 500.00 (HH:MM) (Default : 0.10) Ctrl Set Value >> Setpoint LO limit to Setpoint HI limit (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 25.0) Ctrl Lo Deviation >> For RTD & DC Linear : 0.2 to 99.9 For Thermocouple : 2 to 99 (Default : 2.0) Ctrl Hi Deviation >> Change Password >> For RTD & DC Linear : 0.2 to 99.9 For Thermocouple : 2 to 99 (Default : 2.0) 1 to 100 (Default : 0) SUPERVISORY > SENSOR INPUT Parameters Settings (Default Value) Ctrl Zero Offset >> -50 to 50 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 0.0) Map-1 Zero Offset >> Map-2 Zero Offset >> Map-3 Zero Offset >> Map-4 Zero Offset >> -50 to 50 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 0.0) SUPERVISORY > RECORDING Parameters Settings (Default Value) Rec. Interval (min) >> Alarm Toggle Record >> 0 to 250 Min (Default : 5 Min) Enable Disable (Default : Enable) Del Print Records >> Del Display Record >> RTC Time >> Yes No (Default : No) Yes No (Default : No) 0 to 23 for Hour 0 to 59 for Min (Default : NA) RTC Date >> 1 to 31 (Default : NA) RTC Month >> 1 to 12 (Default : NA) RTC Year >> 2000 to 2099 (Default : NA) SUPERVISORY > CONTROL Parameters Settings (Default Value) Tune >> Setpoint LO Limit >> Setpoint HI Limit >> Compressor Setpoint >> Compressor Hyst >> Yes No (Default : No) Min Range for the Selected Input Type to Setpoint HI Limit (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 0.0) Setpoint LO Limit to Max Range for the Selected Input Type (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 600.0) 0 to 100 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple) (Default : 45.0) 0.1 to 99.9 (Default : 2.0) Heat Ctrl Action >> ON-OFF PID (Default : PID) Heat Hyst >> 0.1 to 99.9 (Default : 0.2) Heat Only Control Heat + Cool Control Zone : Single Heat + Cool Control Zone : Dual Proportional Band >> Proportional Band >> 0.1 to 999.9 0.1 to 999.9 (Default : 50.0) (Default : 50.0) PrCozpoPrrtioopnaBl aBnadnd>>for Cool Pre-dominant zone 0.1 to 999.9 (Default : 50.0) Integral Time >> 0 to 3600 sec (Default : 100 sec) Integral Time >> 0 to 3600 sec (Default : 100 sec) CzInItnetgergarlaTlimTiemfeor>> Cool Pre-dominant zone 0 to 3600 sec (Default : 100 sec) Derivative Time >> 0 to 600 sec (Default : 16 sec) Derivative Time >> 0 to 600 sec (Default : 16 sec) Cz Derivative Time >> Derivative Time for Cool Pre-dominant zone 0 to 600 sec (Default : 16 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) PrHozpoPrrtoiopnaBl aBnadnd>>for Heat Pre-dominant zone 0.1 to 999.9 (Default : 50.0) Overshoot Inhibit >> Enable Disable Overshoot Inhibit >> Enable Disable HzInIntetgergarlaTlimTiemfeor>> Heat Pre-dominant zone (Default : Disable) (Default : Disable) 0 to 3600 sec (Default : 100 sec) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) Hz Derivative Time >> Derivative Time for Heat Pre-dominant zone 0 to 600 sec (Default : 16 sec) Cycle Time >> 0.5 to 100.0 sec (Default : 10.0 sec) Overshoot Inhibit >> Enable Disable (Default : Disable) Cutoff Factor >> 1.0 to 2.0 sec (Default : 1.2 sec) SUPERVISORY > PRINTER SETTING Parameters Settings (Default Value) Line Per Page >> 25 to 100 (Default : 65) Top Margine >> 1 to 5 (Default : 2) Bottom Margine >> Header & Footer >> Enable >> 1 to 5 (Default : 2) No On First Page Every Page (Default : No) Yes No (Default : No) SUPERVISORY > PRINT EVENT Parameters Settings (Default Value) Alarm Toggle >> RTC Modify >> Interval Modify >> Power Up >> Door Open >> Yes No (Default : Yes) Mains Fail >> Setpoint Modify >> SUPERVISORY > PASSWORD Parameters Settings (Default Value) Change Password >> 1000 to 1999 (Default : 123) SUPERVISORY > EXIT Parameters Settings (Default Value) Exit Setup Mode >> Yes No (Default : No) FACTORY > CONTROL SENSOR INPUT Parameters Settings (Default Value) Input Type >> Refer Table 1 (Default : RTD Pt100) Signal LO >> Input Type Settings Default 0 to 20mA 0.00 to Signal High 0.00 4 to 20mA 4.00 to Signal High 4.00 0 to 5V 0 to 10V 1 to 5V 0.000 to Signal High 0.000 0.00 to Signal High 0.00 1.000 to Signal High 1.000 Signal HI >> Range LO >> Range HI >> Input Type Settings Default 0 to 20mA Signal Low to 20.00 20.00 4 to 20mA Signal Low to 20.00 20.00 0 to 5V Signal Low to 5.000 5.000 0 to 10V Signal Low to 10.00 10.00 1 to 5V Signal Low to 5.000 5.000 -199.9 to RANGE HI (Default : 0.0) RANGE LO to 999.9 (Default : 100.0) FACTORY > MAPPING PARAMETERS Parameters Settings (Default Value) Mapping Points >> 0 to 4 (Default : 0) Input Type >> Refer Table 1 (Default : RTD Pt100) Signal LO >> Input Type Settings Default 0 to 20mA 0.00 to Signal High 0.00 4 to 20mA 4.00 to Signal High 4.00 0 to 5V 0 to 10V 1 to 5V 0.000 to Signal High 0.000 0.00 to Signal High 0.00 1.000 to Signal High 1.000 Signal HI >> Range LO >> Range HI >> Input Type Settings Default 0 to 20mA Signal Low to 20.00 20.00 4 to 20mA Signal Low to 20.00 20.00 0 to 5V Signal Low to 5.000 5.000 0 to 10V Signal Low to 10.00 10.00 1 to 5V Signal Low to 5.000 5.000 -199.9 to RANGE HI (Default : 0.0) RANGE LO to 999.9 (Default : 100.0) FACTORY > ALARM PARAMETERS Parameters Settings (Default Value) Hysteresis >> 0.1 to 99.9 (Default : 0.2) Inhibit >> Yes No (Default : Yes) FACTORY > HEAT COOL SELECT Parameters Settings (Default Value) Control Strategy >> Heat Only Cool Only Heat + Cool (Default : Heat + Cool) Control Strategy : Cool Only Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) Control Strategy : Heat + Cool Compressor Strategy >> CONT. OFF CONT. ON SP BASED PV BASED (Default : CONT. ON) CONT. ON SP BASED PV BASED Time Boundary Time Delay (sec) >> Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) Set Value >> 0 to 100 (Resolution 0.1°C for RTD / DC Linear & 0 to 1000 Sec (Default : 200 Sec) 1°C for Thermocouple) Control Zones >> Single Dual (Default : Single) Time Delay (sec) >> 0 to 1000 Sec (Default : 200 Sec) FACTORY > SOAK TIMER PARAMETERS Parameters Settings (Default Value) Enable >> No Yes (Default : No) Start Band >> 0 to 999.9 (Default : 0.5) Holdback Strategy >> None Up Down Both (Default : None) Hold Band >> 0.1 to 999.9 (Default : 0.5) Heat Off >> Cool Off >> No Yes (Default : No) No Yes (Default : No) Power Recovery >> Abort Restart Continuous (Default : Restart) FACTORY > DOOR OPEN Parameters Settings (Default Value) Enable >> Yes No (Default : No) Switch Logic >> Close : Door Open Open : Door Open (Default : Close : Door Open) Door Alrm Dly (sec) >> 0 to 1000 Sec (Default : 60 Sec) FACTORY > MAINS FAILURE Parameters Settings (Default Value) Enable >> Yes No (Default : No) Switch Logic >> Close : Mains Fail Open : Mains Fail (Default : Close : Mains Fail) 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net FACTORY > PASSWORD Parameters Settings (Default Value) Change Password >> 2000 to 2999 (Default : 321) FACTORY > FACTORY DEFAULT Parameters Settings (Default Value) Set To Default >> Yes No (Default : No) FACTORY > EXIT Parameters Settings (Default Value) Exit Setup Mode >> Yes No (Default : No) What it means TABLE 1 Range (Min. to Max.) Resolution Type J Thermocouple 0 to +960°C Type K Thermocouple -200 to +1376°C Type T Thermocouple Type R Thermocouple Type S Thermocouple -200 to +385°C 0 to +1770°C 0 to +1765°C Fixed 1°C Type B Thermocouple 0 to +1825°C Type N Thermocouple 0 to +1300°C Reserve Reserved for customer specific Thermocouple type not listed above. The type shall be specified in accordance with the ordered (optional on request) Thermocouple type. 3-wire, RTD Pt100 -199.9 to 600.0°C 0 to 20mA DC current Fixed 0.1°C 4 to 20mA DC current 0 to 5.0V DC voltage 0 to 10.0V DC voltage -199.9 to 999.9 units Fixed 0.1 unit 1 to 5.0V DC voltage Jan 2022 FRONT PANEL KEYS Symbol Key Scroll Function Press to scroll through various Process Information Screens in Normal Operation Mode. Alarm Acknowledge Press to acknowledge and mute (if active) alarm output. DOWN UP Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. SET-UP Press to enter or exit set-up mode. ENTER Press to store the set parameter value and to scroll to the next parameter. PV ERROR INDICATIONS Message OPEN OVR UNR Error Type Cause Sensor Open Sensor (RTD Pt100) Broken / Open Over-range Temperature above Max. Specified Range Under-range Temperature below Min. Specified Range ELECTRICAL CONNECTIONS LabCon 4 Map B126-V1 SOAK START ACK BATTERY DOOR COMMON 0 1 2 3 4 34 35 36 37 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 MAP-4 MAP-3 MAP-2 MAP-1 CTRL Sensor Inputs CH - X RS485 Control Outputs COMM HTR CMP ALM +DEV- +PC- + - + - + - 21 22 23 24 25 26 27 28 29 30 RTD TC V / mV Supply 18~32VDC +- 31 32 33 mA PC Printer Recording