LabCon Map Printer

abc

LabCon Map Printer Operator Manual

Temperature control system | Temperature Recorders India - PPI controller


File Info : application/pdf, 2 Pages, 437.69KB

PDF preview unavailable. Download the PDF instead.

Product-065-OM-4
LabCon (MAP + Printer)
Recording + 4 Channel Mapping + Printer Interface

Operation Manual
This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net

OPERATOR PAGE PARAMETERS

Parameters

Settings (Default Value)

Select Print Option>>

None Print (New) Re-Print (Old) Print Info Page
(Default : None)

Time Start Command >> Time Abort Command >> Time Interval (H:M) >>

Yes No (Default : No)
0.00 to 500.00 (HH:MM)
(Default : 0.10)

Ctrl Set Value >>

Setpoint LO limit to Setpoint HI limit
(Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple)
(Default : 25.0)

Ctrl Lo Deviation >>

For RTD & DC Linear : 0.2 to 99.9 For Thermocouple : 2 to 99 (Default : 2.0)

Ctrl Hi Deviation >> Change Password >>

For RTD & DC Linear : 0.2 to 99.9 For Thermocouple : 2 to 99 (Default : 2.0)
1 to 100 (Default : 0)

SUPERVISORY > SENSOR INPUT

Parameters

Settings (Default Value)

Ctrl Zero Offset >>

-50 to 50 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple)
(Default : 0.0)

Map-1 Zero Offset >> Map-2 Zero Offset >> Map-3 Zero Offset >> Map-4 Zero Offset >>

-50 to 50 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple)
(Default : 0.0)

SUPERVISORY > RECORDING

Parameters

Settings (Default Value)

Rec. Interval (min) >> Alarm Toggle Record >>

0 to 250 Min (Default : 5 Min)
Enable
Disable (Default : Enable)

Del Print Records >>
Del Display Record >> RTC Time >>

Yes No (Default : No)
Yes No (Default : No)
0 to 23 for Hour 0 to 59 for Min
(Default : NA)

RTC Date >>

1 to 31 (Default : NA)

RTC Month >>

1 to 12 (Default : NA)

RTC Year >>

2000 to 2099 (Default : NA)

SUPERVISORY > CONTROL

Parameters

Settings (Default Value)

Tune >> Setpoint LO Limit >> Setpoint HI Limit >>
Compressor Setpoint >> Compressor Hyst >>

Yes No (Default : No)
Min Range for the Selected Input Type to Setpoint HI Limit
(Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple)
(Default : 0.0)
Setpoint LO Limit to Max Range for the Selected
Input Type (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple)
(Default : 600.0)
0 to 100 (Resolution 0.1°C for RTD / DC Linear & 1°C for Thermocouple)
(Default : 45.0)
0.1 to 99.9 (Default : 2.0)

Heat Ctrl Action >>

ON-OFF PID
(Default : PID)

Heat Hyst >>

0.1 to 99.9 (Default : 0.2)

Heat Only Control

Heat + Cool Control Zone : Single

Heat + Cool Control Zone : Dual

Proportional Band >> Proportional Band >>

0.1 to 999.9

0.1 to 999.9

(Default : 50.0)

(Default : 50.0)

PrCozpoPrrtioopnaBl aBnadnd>>for Cool Pre-dominant zone
0.1 to 999.9 (Default : 50.0)

Integral Time >> 0 to 3600 sec
(Default : 100 sec)

Integral Time >> 0 to 3600 sec
(Default : 100 sec)

CzInItnetgergarlaTlimTiemfeor>> Cool Pre-dominant zone
0 to 3600 sec (Default : 100 sec)

Derivative Time >>
0 to 600 sec (Default : 16 sec)

Derivative Time >>
0 to 600 sec (Default : 16 sec)

Cz Derivative Time >> Derivative Time for
Cool Pre-dominant zone
0 to 600 sec (Default : 16 sec)

Cycle Time >>
0.5 to 100.0 sec (Default : 10.0 sec)

Cycle Time >>
0.5 to 100.0 sec (Default : 10.0 sec)

PrHozpoPrrtoiopnaBl aBnadnd>>for Heat Pre-dominant zone
0.1 to 999.9 (Default : 50.0)

Overshoot Inhibit >>
Enable Disable

Overshoot Inhibit >>
Enable Disable

HzInIntetgergarlaTlimTiemfeor>> Heat Pre-dominant zone

(Default : Disable)

(Default : Disable)

0 to 3600 sec

(Default : 100 sec)

Cutoff Factor >>
1.0 to 2.0 sec (Default : 1.2 sec)

Cutoff Factor >>
1.0 to 2.0 sec (Default : 1.2 sec)

Hz Derivative Time >> Derivative Time for
Heat Pre-dominant zone
0 to 600 sec (Default : 16 sec)

Cycle Time >>
0.5 to 100.0 sec (Default : 10.0 sec)

Overshoot Inhibit >> Enable Disable
(Default : Disable)
Cutoff Factor >>
1.0 to 2.0 sec (Default : 1.2 sec)

SUPERVISORY > PRINTER SETTING

Parameters

Settings (Default Value)

Line Per Page >>

25 to 100 (Default : 65)

Top Margine >>

1 to 5 (Default : 2)

Bottom Margine >> Header & Footer >>
Enable >>

1 to 5 (Default : 2)
No On First Page Every Page (Default : No)
Yes No (Default : No)

SUPERVISORY > PRINT EVENT

Parameters

Settings (Default Value)

Alarm Toggle >>

RTC Modify >> Interval Modify >> Power Up >> Door Open >>

Yes No
(Default : Yes)

Mains Fail >> Setpoint Modify >>

SUPERVISORY > PASSWORD

Parameters

Settings (Default Value)

Change Password >>

1000 to 1999 (Default : 123)

SUPERVISORY > EXIT

Parameters

Settings (Default Value)

Exit Setup Mode >>

Yes No
(Default : No)

FACTORY > CONTROL SENSOR INPUT

Parameters

Settings (Default Value)

Input Type >>

Refer Table 1 (Default : RTD Pt100)

Signal LO >>

Input Type

Settings

Default

0 to 20mA 0.00 to Signal High 0.00

4 to 20mA 4.00 to Signal High 4.00

0 to 5V 0 to 10V 1 to 5V

0.000 to Signal High 0.000 0.00 to Signal High 0.00 1.000 to Signal High 1.000

Signal HI >>
Range LO >> Range HI >>

Input Type

Settings

Default

0 to 20mA Signal Low to 20.00 20.00

4 to 20mA Signal Low to 20.00 20.00

0 to 5V Signal Low to 5.000 5.000

0 to 10V Signal Low to 10.00 10.00

1 to 5V Signal Low to 5.000 5.000

-199.9 to RANGE HI (Default : 0.0)
RANGE LO to 999.9 (Default : 100.0)

FACTORY > MAPPING PARAMETERS

Parameters

Settings (Default Value)

Mapping Points >>

0 to 4 (Default : 0)

Input Type >>

Refer Table 1 (Default : RTD Pt100)

Signal LO >>

Input Type

Settings

Default

0 to 20mA 0.00 to Signal High 0.00

4 to 20mA 4.00 to Signal High 4.00

0 to 5V 0 to 10V 1 to 5V

0.000 to Signal High 0.000 0.00 to Signal High 0.00 1.000 to Signal High 1.000

Signal HI >>
Range LO >> Range HI >>

Input Type

Settings

Default

0 to 20mA Signal Low to 20.00 20.00

4 to 20mA Signal Low to 20.00 20.00

0 to 5V Signal Low to 5.000 5.000

0 to 10V Signal Low to 10.00 10.00

1 to 5V Signal Low to 5.000 5.000

-199.9 to RANGE HI (Default : 0.0)
RANGE LO to 999.9 (Default : 100.0)

FACTORY > ALARM PARAMETERS

Parameters

Settings (Default Value)

Hysteresis >>

0.1 to 99.9 (Default : 0.2)

Inhibit >>

Yes No
(Default : Yes)

FACTORY > HEAT COOL SELECT

Parameters

Settings (Default Value)

Control Strategy >>

Heat Only Cool Only Heat + Cool
(Default : Heat + Cool)

Control Strategy : Cool Only

Time Delay (sec) >>

0 to 1000 Sec (Default : 200 Sec)

Control Strategy : Heat + Cool

Compressor Strategy >>

CONT. OFF CONT. ON SP BASED
PV BASED (Default : CONT. ON)

CONT. ON

SP BASED

PV BASED

Time

Boundary

Time Delay (sec) >>

Delay (sec) >>
0 to 1000 Sec (Default : 200 Sec)

Set Value >> 0 to 100
(Resolution 0.1°C for RTD / DC Linear &

0 to 1000 Sec (Default : 200 Sec)

1°C for Thermocouple)

Control Zones >> Single Dual
(Default : Single)

Time Delay (sec) >>

0 to 1000 Sec (Default : 200 Sec)

FACTORY > SOAK TIMER PARAMETERS

Parameters

Settings (Default Value)

Enable >>

No Yes (Default : No)

Start Band >>

0 to 999.9 (Default : 0.5)

Holdback Strategy >>

None Up
Down Both
(Default : None)

Hold Band >>

0.1 to 999.9 (Default : 0.5)

Heat Off >> Cool Off >>

No Yes (Default : No)
No Yes (Default : No)

Power Recovery >>

Abort Restart Continuous
(Default : Restart)

FACTORY > DOOR OPEN

Parameters

Settings (Default Value)

Enable >>

Yes No (Default : No)

Switch Logic >>

Close : Door Open Open : Door Open
(Default : Close : Door Open)

Door Alrm Dly (sec) >>

0 to 1000 Sec (Default : 60 Sec)

FACTORY > MAINS FAILURE

Parameters

Settings (Default Value)

Enable >>

Yes No
(Default : No)

Switch Logic >>

Close : Mains Fail Open : Mains Fail
(Default : Close : Mains Fail)

101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net

FACTORY > PASSWORD

Parameters

Settings (Default Value)

Change Password >>

2000 to 2999 (Default : 321)

FACTORY > FACTORY DEFAULT

Parameters

Settings (Default Value)

Set To Default >>

Yes No
(Default : No)

FACTORY > EXIT

Parameters

Settings (Default Value)

Exit Setup Mode >>

Yes No
(Default : No)

What it means

TABLE 1 Range (Min. to Max.)

Resolution

Type J Thermocouple

0 to +960°C

Type K Thermocouple

-200 to +1376°C

Type T Thermocouple Type R Thermocouple Type S Thermocouple

-200 to +385°C 0 to +1770°C 0 to +1765°C

Fixed 1°C

Type B Thermocouple

0 to +1825°C

Type N Thermocouple

0 to +1300°C

Reserve

Reserved for customer specific Thermocouple type not listed above. The type shall be specified in accordance with the ordered (optional on request) Thermocouple type.

3-wire, RTD Pt100

-199.9 to 600.0°C

0 to 20mA DC current

Fixed 0.1°C

4 to 20mA DC current 0 to 5.0V DC voltage 0 to 10.0V DC voltage

-199.9 to 999.9 units

Fixed 0.1 unit

1 to 5.0V DC voltage

Jan 2022

FRONT PANEL KEYS

Symbol

Key
Scroll

Function
Press to scroll through various Process Information Screens in Normal Operation Mode.

Alarm Acknowledge

Press to acknowledge and mute (if active) alarm output.

DOWN UP

Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change.
Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change.

SET-UP

Press to enter or exit set-up mode.

ENTER

Press to store the set parameter value and to scroll to the next parameter.

PV ERROR INDICATIONS

Message
OPEN OVR UNR

Error Type

Cause

Sensor Open Sensor (RTD Pt100) Broken / Open

Over-range Temperature above Max. Specified Range Under-range Temperature below Min. Specified Range

ELECTRICAL CONNECTIONS

LabCon 4 Map B126-V1

SOAK START ACK
BATTERY DOOR
COMMON

0 1 2 3 4 34 35 36 37 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

MAP-4

MAP-3

MAP-2

MAP-1

CTRL

Sensor Inputs
CH - X

RS485

Control Outputs

COMM

HTR CMP ALM

+DEV- +PC- + - + - + -

21 22 23 24 25 26 27 28 29 30

RTD TC V / mV

Supply
18~32VDC
+-
31 32 33

mA

PC

Printer

Recording



References