Toshiba Heat-Air® Series Total Heat Exchange Units
Introducing the new large airflow type (1,500m³/h・2,000m³/h) for the Toshiba Heat-Air® Series!
Release Date: August 2025
Key Features
1. Achieves High External Static Pressure for Large Airflow Ventilation
High external static pressure capability ensures sufficient airflow even over long duct runs, enhancing design flexibility and installation ease. This also helps meet the increased ventilation requirements that have become common since the COVID-19 pandemic.
2. Equipped with High-Efficiency DC Motor
Constant airflow control simplifies ventilation calculations. The unit automatically adjusts ventilation to maintain a constant airflow, adjustable in 1% increments between 30% and 120% of the rated airflow. Constant power control allows for stepless adjustment of static pressure-airflow characteristics, enabling fine-tuning and energy savings. Settings can be adjusted in 1% increments within the 5% to 100% range of maximum power.
3. Supports CO₂/PM2.5 Sensors for Air Environment Monitoring
CO₂ and PM2.5 sensors (optional accessories) display air quality status on the remote control. Ventilation volume can be automatically controlled based on detected concentrations, even when using the constant airflow control mode.
4. Insect-Proof Filter (Optional Accessory) for Easy Maintenance
Insects adhere to the filter surface, preventing them from falling off. A single maintenance cover allows easy removal of both the pre-filter and the insect-proof filter, simplifying cleaning. The filter is washable. Note: The insect-proof filter and the high-performance filter cannot be used together.
5. Centrally Manageable Microcomputer Type
Enables integrated control with Toshiba's VRF air conditioning system "Super Multi u" series and central control systems.
Product Information
Product Name | Model | Rated Voltage | Rated Airflow (m³/h) | Duct Connection (Outdoor/Indoor) | Optional Accessories | Suggested Retail Price (Excluding Tax) |
---|---|---|---|---|---|---|
Commercial Total Heat Exchange Unit, Heat-Air® Ceiling Concealed Type, Basic Type, Microcomputer Type, Made to Order | VN-UM1500RT | Single Phase 200V | 1,500 | Outdoor: 300×700mm, Indoor: φ250mm | Insect-proof filter (for 150/250m³/h models): NF-25RM | ¥1,534,000 |
VN-UM2000RT | 2,000 | Insect-proof filter (for 350m³/h models): NF-35RM | ¥1,730,000 | |||
Insect-proof filter (for 500/650m³/h models): NF-65RM | ¥14,000 | |||||
Insect-proof filter (for 800/1,000m³/h and 1,500/2,000m³/h models): NF-100RM (Requires 2 units for 1,500/2,000m³/h models) | ¥15,200 | |||||
Energy-saving neo remote control: RBC-AMSU52 | ¥16,400 | |||||
CO₂/PM2.5 sensor unit: NRB-1CPS | ¥18,400 | |||||
¥47,000 | ||||||
¥124,000 |
Technical Specifications
Model | Fan Speed Setting | Frequency | Current (A) | Power Consumption (W) | Airflow (m³/h) | External Static Pressure (Pa) | Temperature Exchange Efficiency (%) | Enthalpy Exchange Efficiency (%) | Noise (dB) | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|
VN-UM1500RT | Max (特強) | 50/60Hz | 6.10 | 320 | 1,500 | 245 | 73.5 | 73.5 / 65.5 | 48.0 | 138 |
High (強) | 5.93 | 346 | 1,100 | 127 | 77.5 | 76.5 / 68.5 | 38.5 | 127 | ||
Low (弱) | 2.49 | 134 | 730 | 48 | 83.0 | 83.0 / 77.0 | 29.0 | 48 | ||
VN-UM2000RT | Max (特強) | 7.77 | 205 | 2,000 | 205 | 70.5 | 72.0 / 62.0 | 46.0 | 138 | |
High (強) | 7.30 | 165 | 2,000 | 165 | 70.5 | 72.0 / 62.0 | 45.0 | 165 | ||
Low (弱) | 3.20 | 86 | 1,460 | 86 | 72.5 | 72.5 / 63.5 | 39.0 | 40.0 |
Note: Power consumption, current, and exchange efficiency values are for the rated airflow. Temperature and enthalpy exchange efficiency values are based on the display standards specified in JIS B 8628:2017. Noise levels are measured 1.5m below the center of the unit. Temperature exchange efficiency indicates the average value during cooling and heating.
Static Pressure - Airflow Characteristics (Constant Power Control)
VN-UM1500RT Characteristics:
VN-UM2000RT Characteristics:
Outline Drawings
Other Features
- Energy saving achieved through DC motor adoption.
- Airflow selectable in 3 stages (High, Low, Very Low) with a "Max" notch.
- Constant airflow control is possible (High, Low, Very Low notches).
- Integration with TCC-LINK.u™ enables the construction of central control systems with compatible air conditioning units.
- Optional 65% collection efficiency high-performance filter (JIS B 8628:2017 compliant) can be installed.
- Optional insect-proof filter can be installed.
- Ventilation modes include Total Heat Exchange, Normal Ventilation, and Auto.
- Unbalanced supply/exhaust airflow operation can be selected.
- Built-in wind-driven shutter (EA side) and electric shutter (OA side).
- Duct sizes: Outdoor side 300×700mm, Indoor side φ250mm.
- Can be installed upside down.
- Non-polarized 2-wire wiring is used.
- Supports cold climate operation.
- Input/output terminals are standard (requires optional connector cable).
- Pre-cooling/pre-heating operation (delayed operation) is possible when linked with an air conditioner.
- Remote control operation is supported.
- Automatic night purge function is included.
- Pre-operation and rapid ventilation operations are available.
- 24-hour ventilation settings are compatible.
- PM2.5 compatible filter (optional accessory) can be installed.
- Optional remote controls display temperature and humidity.
- Optional remote controls display CO₂ concentration and PM2.5 concentration when the optional sensor is attached.
- Airflow can be set steplessly in 1% increments of maximum power.
- Features a filter with 82% collection efficiency (mass method).
- Multi-unit group control: Up to 16 units can be connected via TCC-LINK.u™; up to 8 units via TCC-LINK. (Note: One unit of VN-UM1500RT and VN-UM2000RT is composed of two units, so count each unit as 2 for group connection.)
Manufacturer Information
Nippon Carrier Corporation
7F Gate City Osaki West Tower, 1-11-1 Osaki, Shinagawa-ku, Tokyo 141-0032, Japan
For product information search, visit "Carrier Navi": https://www.toshiba-carrier.co.jp/product_search/