Growatt MIN 2500~6000TL-X Series Solar Inverters

Key Features

  • Maximum efficiency 98.4%
  • Dual MPP trackers
  • Type II SPD on DC side
  • Supports export control
  • Touch key and OLED display

Datasheet

ParameterGrowatt MIN Series
MIN 2500TL-XMIN 3000TL-XMIN 3600TL-XMIN 4200TL-XMIN 4600TL-XMIN 5000TL-XMIN 6000TL-X
Input Data
Max. recommended PV power (for module STC)3500W4200W5040W5880W6440W7000W8100W
Max. DC voltage500V500V550V550V550V550V550V
Start voltage100V100V100V100V100V100V100V
MPP work voltage range/nominal voltage80V-500V/360V80V-500V/360V80V-550V/360V80V-550V/360V80V-550V/360V80V-550V/360V80V-550V/360V
Max. input current12.5A/12.5A12.5A/12.5A12.5A/12.5A12.5A/12.5A12.5A/12.5A12.5A/12.5A12.5A/12.5A
Max. short-circuit current16A/16A16A/16A16A/16A16A/16A16A/16A16A/16A16A/16A
Number of independent MPP trackers / strings per MPP tracker2/12/12/12/12/12/12/1
Output (AC)
Rated AC output power2500W3000W3600W4200W4600W5000W6000W
Max. AC apparent power2500VA3000VA3600VA4200VA4600VA5000VA6000VA
Max. output current11.3A13.6A16A19A20.9A22.7A27.2A
AC nominal voltage230V(160V-300V)230V(160V-300V)230V(160V-300V)230V(160V-300V)230V(160V-300V)230V(160V-300V)230V(160V-300V)
AC grid frequency50Hz/60Hz, ±5Hz50Hz/60Hz, ±5Hz50Hz/60Hz, ±5Hz50Hz/60Hz, ±5Hz50Hz/60Hz, ±5Hz50Hz/60Hz, ±5Hz50Hz/60Hz, ±5Hz
Adjustable power factor0.8leading...0.8lagging0.8leading...0.8lagging0.8leading...0.8lagging0.8leading...0.8lagging0.8leading...0.8lagging0.8leading...0.8lagging0.8leading...0.8lagging
THDi<3%<3%<3%<3%<3%<3%<3%
AC connectionSingle phaseSingle phaseSingle phaseSingle phaseSingle phaseSingle phaseSingle phase
Efficiency
Max.efficiency98.2%98.2%98.2%98.4%98.4%98.4%98.4%
Euro weighted efficiency97.1%97.1%97.2%97.5%97.5%97.5%97.5%
MPPT efficiency99.9%99.9%99.9%99.9%99.9%99.9%99.9%
Protection Devices
DC reverse polarity protectionyesyesyesyesyesyesyes
DC switchyesyesyesyesyesyesyes
DC surge protectionType IIType IIType IIType IIType IIType IIType II
Output over current protectionyesyesyesyesyesyesyes
Output over voltage protection-varistoryesyesyesyesyesyesyes
Ground fault monitoringyesyesyesyesyesyesyes
Grid monitoringyesyesyesyesyesyesyes
Integrated all-pole sensitive leakage current monitoring unityesyesyesyesyesyesyes
General Data
Dimensions (W/H/D) in mm375/350/160375/350/160375/350/160375/350/160375/350/160375/350/160375/350/160
Weight10.8KG10.8KG10.8KG10.8KG10.8KG10.8KG10.8KG
Operating temperature range-25°C ... +60°C-25°C ... +60°C-25°C ... +60°C-25°C ... +60°C-25°C ... +60°C-25°C ... +60°C-25°C ... +60°C
Noise emission (typical)≤25 dB(A)≤25 dB(A)≤25 dB(A)≤25 dB(A)≤25 dB(A)≤25 dB(A)≤25 dB(A)
Altitude4000m4000m4000m4000m4000m4000m4000m
Self-Consumption night< 0.5W< 0.5W< 0.5W< 0.5W< 0.5W< 0.5W< 0.5W
TopologyTransformerlessTransformerlessTransformerlessTransformerlessTransformerlessTransformerlessTransformerless
Cooling conceptNaturalNaturalNaturalNaturalNaturalNaturalNatural
Environmental Protection RatingIP65IP65IP65IP65IP65IP65IP65
Relative humidity100%100%100%100%100%100%100%
Features
DC connectionH4/MC4(opt)H4/MC4(opt)H4/MC4(opt)H4/MC4(opt)H4/MC4(opt)H4/MC4(opt)H4/MC4(opt)
AC connectionConnectorConnectorConnectorConnectorConnectorConnectorConnector
DisplayOLED+LEDOLED+LEDOLED+LEDOLED+LEDOLED+LEDOLED+LEDOLED+LED
Interfaces: RS485 / USB / Wi-Fi/ 4G / RFyes / yes / opt/opt/optyes / yes / opt/opt/optyes / yes / opt/opt/optyes / yes / opt/opt/optyes / yes / opt/opt/optyes / yes / opt/opt/optyes / yes / opt/opt/opt
Warranty: 5 years / 10 yearsyes / optyes / optyes / optyes / optyes / optyes / optyes / opt

*1 For VDE-AR-N4105 Max. output power is 4600W

*2 For AS4777, Iac max.: 20.9A

Diagrams and Performance

Efficiency Graph: The graph titled "Growatt MIN 6000 TL-X efficiency" illustrates the inverter's efficiency percentage on the vertical axis against DC voltage in Volts on the horizontal axis. It displays multiple performance curves, indicating that the efficiency remains high across a wide range of DC input voltages, typically peaking around 350-400V.

Topology Diagram: The "Growatt MIN 2.5-6kTL-X topology" diagram outlines the internal electrical structure. It shows DC power input from PV1 and PV2 feeding into DC/DC converters, which are connected to MPPT circuits and a DC switch. This DC power is then converted to AC by a DC/AC converter. The output stage includes an Output Relay, EMI Filters, and an LC Filter. Protection devices such as DC SPD and AC SPD are integrated to safeguard the system.

Certifications

  • CE
  • IEC62109
  • G83
  • VDE0126-1-1
  • VFR2014
  • G59
  • AS4777
  • AS/NZS 3100
  • CEI0-21
  • VDE-AR-N4105
  • EN50438
  • CQC
  • IEC61683
  • IEC60068
  • IEC61727
  • IEC62116

Company Information

GROWATT NEW ENERGY TECHNOLOGY Co., LTD

A: No.28 Guangmming Road, Longteng Community, Shiyan, Baoan District, Shenzhen, P.R.China.

T: +86 755 2747 1900

F: +86 755 2749 1460

E: info@ginverter.com

PDF preview unavailable. Download the PDF instead.

Growatt-MIN-3000-6000-TL-X-Datasheet EN Corel PDF Engine Version 18.1.0.661 CorelDRAW X8

Related Documents

Preview Growatt MIN TL-X Series Solar Inverter User Manual
Comprehensive user manual for the Growatt MIN TL-X series solar inverters, covering installation, operation, safety, specifications, and troubleshooting.
Preview Growatt MIN TL-XE Series Installation and Operation Manual
Comprehensive installation and operation manual for Growatt MIN TL-XE series solar inverters (2500W to 6000W). Covers safety, setup, electrical connections, commissioning, maintenance, troubleshooting, and technical specifications.
Preview Growatt MIN TL-XH Series Inverter: Installation & Operation Manual
Comprehensive guide for the installation, operation, safety, and maintenance of Growatt MIN TL-XH series single-phase hybrid inverters, including models MIN 2500TL-XH through MIN 6000TL-XH. Learn about setup, connections, and troubleshooting.
Preview Growatt CE Declaration of Conformity for Solar Inverters
Official CE Declaration of Conformity from Growatt for a wide range of solar inverter models, confirming compliance with European directives including EMC, Low Voltage, and RoHS, and adherence to harmonized standards.
Preview Growatt MIC TL-X Series PV Grid Inverter Installation and Operation Manual
Comprehensive guide for installing, operating, and maintaining the Growatt MIC TL-X series PV grid inverters. Includes safety instructions, technical specifications, troubleshooting, and compliance information.
Preview Growatt MAX 320-350K-X Solar Inverter Datasheet
Datasheet for the Growatt MAX 320-350K-X series solar inverter, detailing technical specifications, features, and protection devices.
Preview Growatt Introduction and Warranty Procedures for the UK and Ireland Market
This document provides an overview of Growatt's warranty procedures, product warranty periods, scope, and claim process for the UK and Ireland market. It details customer and installer responsibilities, contact information, and online claim submission guidelines.
Preview Growatt APX 5.0~30.0P-S0 Quick Installation Manual
Concise guide for installing the Growatt APX 5.0~30.0P-S0 battery storage system, covering environmental conditions, components, floor and wall-mounted installation procedures, system configuration, connections, and operation.