PeakTech 5065 Digital Lux Meter - Operation Manual

Brand: PeakTech

Model: 5065

Safety Precautions

This product complies with the requirements of the following directives of the European Union for CE conformity: 2014/30/EU (electromagnetic compatibility), 2011/65/EU (RoHS).

The following safety precautions must be observed before operation. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever:

Cleaning the Cabinet

Clean only with a damp, soft cloth and a commercially available mild household cleanser. Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment.

Features

Technical Specifications

Specifications of the PeakTech 5065 Digital Lux Meter
Display5 ½ Counts; max. Displayed Value: 100000
Overrange"OL" is displayed
Low battery indication? is displayed when the battery voltage drops below the operating level
Measurement rate2 times per second, nominal
Measuring Range0 ... 100000 Lux (lm/m²)
0 ... 9290 ftc (lm/ft²)
Accuracy+/- 4% to reference, + 50 digits
Auto Power Offabout 20 min.
Storage temperature-20°C ~ 60°C (Humidity < 80% RH)
Operation temperature0°C ~ 50°C (Humidity < 80% RH)
Power Supplies3 x 1.5V (AAA) Batteries
Dimensions (WxHxD)30 x 121 x 60 mm
Weightabout 180g

Panel Description

The device features several controls and indicators:

Operating Instruction

  1. Activate the unit by pressing the ON/OFF-key.
  2. Remove the protection cover from the photo-diode (pull off upwards).
  3. Press the Unit-key to switch between the two measurement units (LUX or ftc).
  4. To switch on the LCD backlight, press and hold the Unit-button for 2 seconds. To turn off the backlight, press and hold the Unit-button for 2 seconds again.
  5. If applicable, press the Func.-key to activate the Data-Hold function.
  6. If applicable, press the Func.-key again to activate the "MAX" or "MIN" measurement modes.
  7. Move the photo-detector to the light source in a horizontal position.
  8. Read the illuminance value from the LC-Display. If the value exceeds the range, "OL" is displayed.
  9. After the measurement, power off the unit and apply the protection cap to the photo-diode.

Spectral Sensitivity Characteristic

The spectral sensitivity characteristic of the detector, using a photo diode with filters, closely matches the C.I.E. (International Commission on Illumination) photopia curve V(λ). This is illustrated in the following chart:

A graph titled 'Spectral Sensitivity' shows relative sensitivity on the Y-axis (from 0% to 100%) against Wavelength (nm) on the X-axis (from 400 to 700 nm). The curve peaks around 550 nm, representing the human eye's peak sensitivity, and drops off towards the blue and red ends of the visible spectrum, aligning with C.I.E. photopic curve V(λ).

Recommended LUX-values for various environments

Recommended Lux values for different environments and workplaces
Environment / WorkplaceLux Value
Office
Conference, Reception room200 – 750
Clerical work700 – 1500
Typing drafting1000 – 2000
Factory
Packing work, Entrance passage150 – 300
Visual work at production line300 – 750
Inspection work750 – 1500
Electronic parts assembly line1500 – 3000
Hotel
Public room, Cloakroom100 – 200
Reception, Cashier200 – 1000
Store
Indoor stairs, Corridors150 – 200
Show window, Packing table750 – 1500
Forefront of show window1500 – 3000
Hospital
Sickroom, Warehouse100 – 200
Medical examination room300 – 750
Operating room, Emergency treatment750 – 1500
School
Auditorium, Indoor Gymnasium100 – 300
Class room200 – 750
Laboratory Library, Drafting room500 – 1500

Maintenance

Battery replacement should only be done if power is off.

Battery Replacement

If the sign "BAT" ? appears on the LCD display, it indicates that the battery should be replaced. Remove screws on the back cover and open the case. Replace the exhausted battery with a new battery.

Used-up batteries are hazardous and must be disposed of properly in designated collection containers.

Statutory Notification about the Battery Regulations

The delivery of many devices includes batteries, which for example serve to operate the remote control. There could also be batteries or accumulators built into the device itself. In connection with the sale of these batteries or accumulators, we are obliged under the Battery Regulations to notify our customers of the following:

Please dispose of old batteries at a council collection point or return them to a local shop at no cost. Disposal in domestic refuse is strictly forbidden according to the Battery Regulations. You can return used batteries obtained from us at no charge at the address on the last side in this manual or by posting with sufficient stamps.

Batteries containing harmful substances are marked with the symbol of a crossed-out waste bin ?️❌. Under the waste bin symbol is the chemical symbol for the harmful substance, e.g., "Cd" for cadmium, "Pb" for lead, and "Hg" for mercury.

Further information about the Battery Regulations can be obtained from the Bundesministerium für Umwelt, Naturschutz und Reaktorsicherheit (Federal Ministry of Environment, Nature Conservation and Reactor Safety).

Legal and Calibration Information

All rights, including translation, reprinting, and copying of this manual or parts thereof, are reserved. Reproductions of all kinds (photocopy, microfilm, or other) are only permitted with written permission from the publisher.

This manual is based on the latest technical knowledge. Technical alterations are reserved.

We herewith confirm that the unit is calibrated by the factory according to the specifications as per the technical specifications.

We recommend calibrating the unit again after one year.

© PeakTech® 01/2021/pt/Sch/pt/HR/Ehr

Manufacturer: PeakTech Prüf- und Messtechnik GmbH - Gerstenstieg 4 – DE-22926 Ahrensburg / Germany

Contact: +49 (0) 4102 97398-80 | +49 (0) 4102 97398-99 | info@peaktech.de | www.peaktech.de

Models: 5065 Digital Lux Meter, 5065, Digital Lux Meter, Lux Meter, Digital Meter, Meter

PDF preview unavailable. Download the PDF instead.

PeakTech 5065 01-2021 DE-EN Microsoft Word 2016 Microsoft Word 2016

Related Documents

Preview PeakTech 5175 Digital Sound Level Meter Operation Manual
Comprehensive operation manual for the PeakTech 5175 Digital Sound Level Meter, detailing safety instructions, features, technical specifications, operating procedures, and battery information.
Preview PeakTech 5307 pH/EC/TDS/Temp Meter Operation Manual
Comprehensive operation manual for the PeakTech 5307, a 4-in-1 pH, EC, TDS, and temperature meter. Includes safety precautions, operating instructions, calibration procedures, battery replacement, and specifications.
Preview PeakTech 9020A DVB-Tester Bedienungsanleitung
Umfassende Bedienungsanleitung für den PeakTech 9020A DVB-Tester. Dieses digitale Messgerät unterstützt DVB-S/S2, DVB-T/T2 und DVB-C/C2 Signale und bietet Funktionen wie Spektrumanalyse, Kanalverwaltung und PVR für Satelliteninstallation und -wartung.
Preview PeakTech 5620 Wärmebildkamera: Umfassende Bedienungsanleitung
Erfahren Sie alles über die PeakTech 5620 Wärmebildkamera mit dieser detaillierten Bedienungsanleitung. Enthält Informationen zu Funktionen, sicherer Bedienung, Messmodi, Konfigurationen und technischen Spezifikationen für professionelle Anwendungen.
Preview PeakTech 3432 Fuse Finder User Manual
User manual for the PeakTech 3432 Fuse Finder, a device for locating fuses in electrical circuits. Includes safety instructions, operating principles, and technical specifications.
Preview PeakTech 3131eff Digital AC/DC Clamp Meter - Operation Manual
Comprehensive operation manual for the PeakTech 3131eff Digital AC/DC Clamp Meter, covering safety precautions, technical specifications, front panel details, operation procedures, and maintenance.
Preview PeakTech 8005 Sound Level Meter User Manual
Comprehensive user manual for the PeakTech 8005 Sound Level Meter, covering safety precautions, operation, PC software integration, technical specifications, and battery replacement.
Preview PeakTech 3202 Analog Voltmeter Bedienungsanleitung & Technische Daten
Entdecken Sie das PeakTech 3202 Analog-Voltmeter mit dieser umfassenden Bedienungsanleitung. Enthält detaillierte Sicherheitsrichtlinien, technische Spezifikationen für Gleich- und Wechselspannungsmessungen sowie Anwendungsbereiche.