Installation Guide for BITMAIN models including: DR5 Server, DR5, Server

DR5 Server Installation Guide 5.15

huizhen.hu


File Info : application/pdf, 15 Pages, 993.88KB

PDF preview unavailable. Download the PDF instead.

DR5 Server Manual
DR5 Server
Installation Guide
Document Version 0.1
Jan. 2019
© Copyright Bitmain Technologies Holding Company 2007 ­ 2022. All rights reserved. Bitmain Cayman (hereinafter referred to as `Bitmain') reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain's terms and conditions of sale supplied at the time of order acknowledgment. Bitmain warrants performance of its products to the specifications applicable at the time of sale in accordance with Bitmain's standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.

DR5 Server Installation Guide
Bitmain assumes no liability for third-party applications assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used. Information published by Bitmain regarding third-party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain. Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements. All company and brand products and service names are trademarks or registered trademarks of their respective holders. All text and figures included in this publication are the exclusive property of Bitmain, and may not be copied, reproduced, or used in any way without the express written permission of Bitmain. Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain. Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be free of errors or omissions. Bitmain reserves the right to make corrections, updates, revisions or changes to the information in this document. Bitmain Tel:+86-400-890-8855 www.bitmain.com
-2 -

DR5 Server Installation Guide
Table of Contents 1. Overview..................................................................................................................................................... 4
1.1 DR5 Server Components...................................................................................................................... 5 1.2 Specifications................................................................................................................................... 7 2. Setting Up the Server...................................................................................................................................9 3. Configuring the Server............................................................................................................................... 11 4. Monitoring Your Server............................................................................................................................. 12 5. Administering Your Server........................................................................................................................ 13 5.1 Checking Your Firmware Version...................................................................................................... 13 5.2 Upgrading Your System....................................................................................................................13 5.3 Modifying Your Password................................................................................................................ 14 5.4 Restoring Initial Settings...................................................................................................................14 Regulations................................................................................................................................................. 15
-3 -

DR5 Server Installation Guide 1. Overview
1. Overview
The DR5 server is Bitmain's newest version in the DR5 server series. Power supply APW8 is part of DR5 server. All DR5 servers are tested and configured prior to shipping to ensure easy set up.
-4 -

DR5 Server Installation Guide 1. Overview
1.1 DR5 Server Components
The main components and controller front panel of DR5 server are shown in the following figure:
-5 -

APW8 Power Supply:

DR5 Server Installation Guide 1. Overview

-6 -

DR5 Server Installation Guide 1. Overview

1.2 Specifications
Model No.: 240-A Version: DR5
Product Glance
Crypto Algorithm Hashrate, TH/s
Reference power on wall, Watt
Reference power efficiency on wall @25°C, J/TH
Detailed Characteristics
Hashrate & Power Hashrate, TH/s
Power efficiency on wall @25°C, J/TH
Power efficiency on wall @40°C, J/TH
Power on wall, Watt (1-2) Power supply AC input voltage, Volt (1-3) Power supply AC input current, Amp(1-4)
Power supply Input AC Frequency Range, Hz
Hardware Configuration Quantity of hash chips Quantity of hash boards Networking connection mode

Normal
35.00 1610 46.00

Value
Low Power Blake256R14
25.00~26.00 1000~1040
40.00

Value

Min

Typ

Max

Normal Low Power Normal Low Power Normal Low Power Normal Low Power
Normal Low Power

46.00 40.00 47.53 41.42 1610 1000 200
47

35.00 25.00~26.00
220 7.32 4.55
50

35.95 +3%
(1-1)
49.22 42.80 50.86 44.32 1828 1187 240 9.14 5.94
63

216 3
RJ45 Ethernet 10/100M

-7 -

DR5 Server Installation Guide 1. Overview

Server Size (Length*Width*Height, w/o package),mm(2-1) Net weight, kg (2-2) Noise, dBA @25°C (2-3) Environmental Requirements Operation temperature,°C Storage temperature,°C
Operation humidity, RH(no condensation)

238*178*297 7.75

0

25

-4

25

0

5%

76
40 85 95%

Notes: (1-1) In Low Power Mode, Max Hashrate is about Typ hashrate *103% (1-2) Min condition: 25°C, min J/TH, typical hashrate
Max condition: 40°C, max J/TH, max hashrate (1-3) Caution: Wrong input voltage may probably cause server damaged (1-4) Typ condition: min reference power, typical AC input voltage
Max condition: max reference power, min AC input voltage (2-1) Including PSU size (2-2) Including PSU weight (2-3) Max condition: Fan is under max RPM(rotation per minute)

Specifications for APW8:

Input
Environment Cooling System

Voltage Range Frequency Range Power Factor Leakage Current Overheat Protection Operating Temperature Operating Humidity
Fan

200-240V AC 50/60Hz >0.99 <2mA Yes
0-40
5%RH-95%RH(non---condensing ) forced---air cooling

-8 -

DR5 Server Installation Guide 2. Setting Up the Server
2. Setting Up the Server
To set up the server: The file IPReporter.zip is supported by Microsoft Windows only.
1. Go to the following site:https://shop.bitmain.com/support/download
2. Choose `Others' and download the following file: IPReporter.zip 3. Extract the file.
The default DHCP network protocol distributes IP addresses automatically. 4. Right-click IPReporter.exe and run it as Administrator. 5. Select one of the following options:
 Shelf, Step, Position ­ suitable for farm servers to mark the location of the servers.  Default ­ suitable for home servers. 6. Click Start.
-9 -

DR5 Server Installation Guide 2.Setting Up the server
7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).
The IP address will be displayed in a window on your computer screen.
8. In your web browser, enter the IP address provided. 9. Proceed to login using root for both the username and password. 10. In the Network section, you can assign a DHCP IP address (optional). 11. Click Save & Apply.
- 10 -

3. Configuring the Server
Setting Up the Pool
To configure the server: 1. click General Settings

DR5 Server Installation Guide 3. Configuring the Server

2. Set the options according to the following table:

Option Pool URL

Description Enter the URL of your desired pool.
The DR5 server can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher priority pools are offline.

Worker Password

Your worker ID on the selected pool. The password for your selected worker.

3. Click Save & Apply to save and restart the server.

- 11 -

4. Monitoring Your server
To check the operating status of your server:
1. Click the status marked below.

DR5 Server Installation Guide 4. Monitoring Your Server

2. monitor your server according to the descriptions in the following table:

Option

Description

ASIC#

Number of chips detected in the chain.

Frequency GH/S(RT) Temp(PCB)

ASIC frequency setting. Hash rate of each hash board ( GH/s) Temperature of each hash board (°C).(Applied only to server with fixed frequency)

Temp(Chip) ASIC status

Temperature of the chips on each hash board (°C). One of the following statuses will appear:

 O - indicates OK

 X - indicates error  - - indicates dead

- 12 -

DR5 Server Installation Guide 5. Administering Your Server
5. Administering Your Server
5.1 Checking Your Firmware Version
To check your firmware version: 1. In System, click the Overview tab. 2. File System Version displays the date of the firmware your server use. In the example below, the server is
using firmware version 20181211.
5.2 Upgrading Your System
Make sure that the DR5 server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair. To upgrade the server's firmware: 1. In System, click Upgrade.
- 13 -

DR5 Server Installation Guide 5. Administering Your Server

2. For Keep Settings:

 Select the check box to keep your current settings (default).

 Clear the check box to reset the server to default settings.

3. Click the

(Browse) button and navigate to the upgrade file. Select the upgrade file, then click

Flash image.A message appears notifying you if the DR5 firmware can be upgraded and if yes, will then

proceed to flash the image.

4. When the upgrade is completed, the following message appears:

5. Click one of the following options:  Reboot - to restart the server with the new firmware.  Go Back - to continue mining with the current firmware. The server will load the new firmware next time it is restarted.
5.3 Modifying Your Password
To change your login password: 1. In System, click the Administration tab. 2. Set your new password, then click Save & Apply.

5.4 Restoring Initial Settings
To restore your initial settings 1. Turn on the server and let it run for 5 minutes. 2. On the controller front panel, press and hold the Reset button for 10 seconds.
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
- 14 -

DR5 Server Installation Guide

Regulations: FCC Notice (FOR FCC CERTIFIED MODELS):

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where your purchased the product.
 ROHS:


  

DR5 240-A 









 

(Pb)

Hg

Cd

(Cr+6)

PBB PBDE













--











--











 1. 0.1 wt % 0.01 wt % 
 2.  3.

- 15 -



References

WPS 文字