FIBRE SPLITTER
NORDEN
PLC (Planar Lightwave Circuit) splitters are utilized to distribute or combine optical signals. Based on planar lightwave circuit technology, they offer a low-cost solution with a small form factor and high reliability. PLC Splitters are installed in optical networks between the PON Optical Line Terminal (OLT) and the Optical Network Terminals (ONTs) that the OLT serves. Networks implementing BPON, GPON, EPON, 10G EPON, and 10G GPON technologies all use these optical splitters. In place of an optical splitter, a WDM PON network will use an Arrayed Waveguide (AWG). Passive Optical Network (PON) splitters play a crucial role in Fibre to the Home (FTTH) networks by enabling a single PON network interface to be shared among multiple subscribers.
[Image Description: A NORDEN branded optical fibre splitter. It features a small, rectangular, grey cassette-like unit with fiber optic connectors on one side, and a longer, thin, steel-tube-like component with a fiber optic cable extending from it on the other. A ROHS compliance logo is also visible.]
Features
- Low Insertion Loss & Low PDL (Polarization Dependent Loss).
- Good Channel-to-Channel uniformity.
- Wide Operating Wavelength (1260 nm to 1650 nm).
- Excellent Environmental Stability.
Design & Materials
Splitter Type | Steel Tube PLC Splitter, Cassette PLC Splitter, FBT Type Splitter |
Configuration Type | 1x2, 1x4, 1x8, 1x16, 1x32, 1x64 2x2, 2x4, 2x8, 2x16, 2x32, 2x64 |
Fibre Type | Single mode (G657.A) |
Connector Type | SC, LC, FC |
Fibre Diameter | 250μm, 900μm |
Fiber Length | 1.0m |
Operating Temperature | -40°C to 85°C |
Storage Temperature | -40°C to 85°C |
1xN PLC Optical Splitter Specifications
Model | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 |
---|---|---|---|---|---|---|
Wavelength | 1260-1650 | |||||
Insertion Loss (Max dB) | 4.2 | 7.2 | 10.5 | 13.7 | 17.0 | 20.6 |
Channel Uniformity (Max dB) | 0.6 | 0.8 | 1.0 | 1.6 | 1.6 | 2.0 |
Polarization Dependent Loss (Max dB) | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss (Min dB) | 55.0 | |||||
Direction (Min dB) | 55.0 | |||||
250um Basic type PLC splitter (HxWxL mm) | 4x7x40 | 4x7x50 | 4x7x50 | 4x20x80 | 4x7x50 | 4x12x60 |
900um Steel tube type PLC splitter (HxWxL mm) | 4x7x60 | 4x12x60 | 4x20x80 | 6x40x100 | 4x12x60 | 6x40x100 |
Cassette type PLC splitter (HxWxL mm) | 10x80x100 | 18x80x120 | 18x115x140 | 18x115x140 | 18x115x140 | 18x115x140 |
2xN PLC Optical Splitter Specifications
Model | 2x2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 |
---|---|---|---|---|---|---|
Wavelength | 1260-1650 | |||||
Insertion Loss (Max dB) | 4.2 | 7.3 | 11.5 | 14.3 | 17.5 | 21.0 |
Channel Uniformity (Max dB) | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 |
Polarization Dependent Loss (Max dB) | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss (Min dB) | 55.0 | |||||
Direction (Min dB) | 55.0 | |||||
250um Basic type PLC splitter (HxWxL mm) | 4x7x50 | 4x7x60 | 4x7x60 | 4x12x60 | 4x7x60 | 4x12x60 |
900um Steel tube type PLC splitter (HxWxL mm) | 4x7x60 | 4x12x70 | 6x20x80 | 6x40x100 | 6x20x80 | 6x40x100 |
Cassette type PLC splitter (HxWxL mm) | 10x80x100 | 18x80x120 | 18x115x140 | 18x115x140 | 18x115x140 | 18x115x140 |
Ordering Information
Part Number | Description |
---|---|
39-4S32S30N | SC/APC Single Mode 1x32 Steel Tube Bare Fibre Splitter |
39-4S16S30N | SC/APC Single Mode 1x16 Steel Tube Bare Fibre Splitter |
39-4S08S30N | SC/APC Single Mode 1x8 Steel Tube Bare Fibre Splitter |
39-4S04S30N | SC/APC Single Mode 1x4 Steel Tube Bare Fibre Splitter |
39-4S02S30N | SC/APC Single Mode 1x2 Steel Tube Bare Fibre Splitter |
39-4S0200MN | Single Mode 1x2 Steel Tube Bare Fibre Splitter without Connector |
39-4S0400MN | Single Mode 1x4 Steel Tube Bare Fibre Splitter without Connector |
39-1S0400MN | Single Mode 2x4 Steel Tube Bare Fibre Splitter without Connector |
39-4S0800MN | Single Mode 1x8 Steel Tube Bare Fibre Splitter without Connector |
39-4S1600MN | Single Mode 1x16 Steel Tube Bare Fibre Splitter without Connector |
39-4S3200MN | Single Mode 1x32 Steel Tube Bare Fibre Splitter without Connector |
39-4A0400MN | Single Mode 1x4 G657.A1 Steel Tube Bare Fibre Splitter without Connector |
39-4A0800MN | Single Mode 1x8 G657.A1 Steel Tube Bare Fibre Splitter without Connector |
39-4A1600MN | Single Mode 1x16 G657.A1 Steel Tube Bare Fibre Splitter without Connector |
39-1S1600MN | Single Mode 2x16 Steel Tube Bare Fibre Splitter without Connector |
39-7A04S3PX | Single Mode 1x4 G657.A1 SC/APC Cassette Splitter With Connector |
39-8A08S3PX | Single Mode 2x8 G657.A1 SC/APC Cassette Splitter With Connector |
39-7A32S3PX | Single Mode 1x32 G657.A1 SC/APC Cassette Splitter With Connector |
39-4A02S20N | Single Mode 1X2 G657.A1 Steel Tube Bare Fibre Splitter with SC/UPC Connector |
39-4A04S20N | Single Mode 1X4 G657.A1 Steel Tube Bare Fibre Splitter with SC/UPC Connector |
39-4A08S20N | Single Mode 1X8 G657.A1 Steel Tube Bare Fibre Splitter with SC/UPC Connector |
39-4A08S30N | Single Mode 1X8 G657.A1 Steel Tube Bare Fibre Splitter with SC/APC Connector |
39-9A16F2PX | Single Mode 1x16 G657.A1 FC/UPC FBT Splitter With Connector |
39-9A02F2PX | Single Mode 1x2 G657.A1 FC/UPC FBT Splitter With Connector |
39-9A02S2PX | Single Mode 1x2 G657.A1 SC/UPC FBT Splitter With Connector |
39-7A04F2PX | Single Mode 1x4 G657.A1 FC/UPC Cassette Splitter With Connector |
39-7A08F2PX | Single Mode 1x8 G657.A1 FC/UPC Cassette Splitter With Connector |
39-4A16S2MN | Single Mode 1X16 G657.A1 Steel Tube Bare Fibre Splitter with SC/UPC Connector |
39-1A16S2MN | Single Mode 2X16 G657.A1 Steel Tube Bare Fibre Splitter with SC/UPC Connector |
39-1A04S3MX | Single Mode 2x4 G657.A1 Steel Tube Bare Fibre Splitter With SC/APC Connector |
39-1A08S3MX | Single Mode 2x8 G657.A1 Steel Tube Bare Fibre Splitter With SC/APC Connector |
39-1A32L3MX | Single Mode 2x32 G657.A1 Steel Tube Bare Fibre Splitter With LC/APC Connector |
39-1A16L3MX | Single Mode 2x16 G657.A1 Steel Tube Bare Fibre Splitter With LC/APC Connector |
39-4A02L3MX | Single Mode 1x2 G657.A1 Steel Tube Bare Fibre Splitter With LC/APC Connector |
39-1A04L3MX | Single Mode 2x4 G657.A1 Steel Tube Bare Fibre Splitter With LC/APC Connector |
39-1A08L3MX | Single Mode 2x8 G657.A1 Steel Tube Bare Fibre Splitter With LC/APC Connector |
Note: Above Parameters Without Connector. Each Connector will add 0.2 dB.
Website: www.nordencommunication.com