PXIe-5110

Letter of Volatility NI 5110/5111/5113

Manufacturer: National Instruments

Board Assembly Part Numbers (Refer to Procedure 1 for identification procedure):

Part Number and Revision Description

147871A-10L or later

PXIE-5110 OSCILLOSCOPE,100 MHZ,32MB

147871A-11L or later

PXIE-5110 OSCILLOSCOPE,100 MHZ,256MB

147871A-30L or later

PXIE-5111 OSCILLOSCOPE,350 MHZ,32MB

147871A-31L or later

PXIE-5111 OSCILLOSCOPE,350 MHZ,256MB

147871A-50L or later

PXIE-5113 OSCILLOSCOPE,350 MHZ,32MB

147871A-51L or later

PXIE-5113 OSCILLOSCOPE,350 MHZ,256MB

Volatile Memory
Target Data Waveform data

Type DRAM

Size 32MB (-x0L) 256MB (-x1L)

Battery User1

System Sanitization

Backup Accessible Accessible Procedure

No

Yes

Yes Cycle Power

Non-Volatile Memory (incl. Media Storage)

Target Data
Device information · Factory data · Self-calibration data · External cal. data2 · Misc info · FPGA bitstream

Type Flash

Size 16 MB

FPGA

Intel 10M04SAU

Battery Backup
No
No

User

System Sanitization

Accessible Accessible Procedure

No

Yes

None

No

Yes

None

No

Yes

None

Yes

Yes Procedure 2

No

Yes

None

Spread spectrum clock config
ASIC configuration

EEPROM 48 Bytes

No

EEPROM

32 kB

No

No

No

No

Yes

None None

1 Refer to Terms and Definitions section for clarification of User and System Accessible 2 Calibration constants that are stored on the device include information for the device's full operating range.

September 2018 377821A-01 Rev 001

Notice: This document is subject to change without notice. For the most recent version, visit ni.com/manuals.

Contact: 866-275-6964 support@ni.com

Letter of Volatility NI 5110/5111/5113
Procedures
Procedure 1 ­ Board Assembly Part Number Identification: To determine the Board Assembly Part Number and Revision, refer to the label applied to the surface of your product. The Assembly Part Number should be formatted as "P/N: 147871a-xxL where "a" is the letter revision of the assembly (e.g. A, B, C...) and "xx" is the variant.
Procedure 2 ­ Calibration Flash: The user-accessible areas of the Calibration Flash are exposed through a calibration Applications Programming Interface (API) in LabVIEW. All the VIs used are located in the NI-SCOPE/Calibration/PXIe-5110 Ext Cal palette. To clear the calibration user-data area, complete the following steps:
1. The calibration password cannot be changed without knowing what the calibration password is already. The default as-shipped from factory is "NI". To change the password, use /Utility/Change Ext Cal Password.vi, passing it the old password and the new password. Screenshot for the location of the VI in the sub-palette is shown below.

2. To clear the user-defined information, open an external cal session using the Open Ext Cal Session VI.
Screenshot for the VI location is shown below. In that session, call the Set Misc Info VI, passing it an
arbitrary 4 character string to use in overwriting the data. Close the session using the Close Ext Cal Session, using the commit action. The commit action in the close session is an input named "action" with "Cancel" and "Commit" as the two options. Use the "Commit".

September 2018 377821A-01 Rev 001

Notice: This document is subject to change without notice. For the most recent version, visit ni.com/manuals.

Contact: 866-275-6964 support@ni.com

Letter of Volatility NI 5110/5111/5113

September 2018 377821A-01 Rev 001

Notice: This document is subject to change without notice. For the most recent version, visit ni.com/manuals.

Contact: 866-275-6964 support@ni.com

Letter of Volatility NI 5110/5111/5113
Terms and Definitions
Cycle Power: The process of completely removing power from the device and its components and allowing for adequate discharge. This process includes a complete shutdown of the PC and/or chassis containing the device; a reboot is not sufficient for the completion of this process.
Volatile Memory: Requires power to maintain the stored information. When power is removed from this memory, its contents are lost. This type of memory typically contains application specific data such as capture waveforms.
Non-Volatile Memory: Power is not required to maintain the stored information. Device retains its contents when power is removed. This type of memory typically contains information necessary to boot, configure, or calibrate the product or may include device power up states.
User Accessible: The component is read and/or write addressable such that a user can store arbitrary information to the component from the host using a publicly distributed NI tool, such as a Driver API, the System Configuration API, or MAX.
System Accessible: The component is read and/or write addressable from the host without the need to physically alter the product.
Clearing: Per NIST Special Publication 800-88 Revision 1, "clearing" is a logical technique to sanitize data in all User Accessible storage locations for protection against simple non-invasive data recovery techniques using the same interface available to the user; typically applied through the standard read and write commands to the storage device.
Sanitization: Per NIST Special Publication 800-88 Revision 1, "sanitization" is a process to render access to "Target Data" on the media infeasible for a given level of effort. In this document, clearing is the degree of sanitization described.

September 2018 377821A-01 Rev 001

Notice: This document is subject to change without notice. For the most recent version, visit ni.com/manuals.

Contact: 866-275-6964 support@ni.com

