Instruction Manual for JamesHardie models including: HardiePlank Lap Siding
File Info : application/pdf, 4 Pages, 15.60MB
DocumentDocumentHardiePlank® Lap Siding EFFECTIVE DECEMBER 2019 IMPORTANT: FAILURE TO FOLLOW JAMES HARDIE WRITTEN INSTALLATION INSTRUCTIONS AND COMPLY WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS, AFFECT BUILDING ENVELOPE PERFORMANCE AND MAY AFFECT WARRANTY COVERAGE. FAILURE TO COMPLY WITH ALL HEALTH AND SAFETY REGULATIONS WHEN CUTTING AND INSTALLING THIS PRODUCT MAY RESULT IN PERSONAL INJURY. BEFORE INSTALLATION, CONFIRM YOU ARE USING THE CORRECT HARDIEZONE® PRODUCT INSTRUCTIONS BY VISITING HARDIEZONE.COM OR CALL 1-866-942-7343 (866-9-HARDIE) STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge. Protect edges and corners from breakage. James Hardie is not responsible for damage caused by improper storage and handling of the product. CUTTING INSTRUCTIONS OUTDOORS 1. Position cutting station so that airflow blows dust away from the user and others near the cutting area. 2. Cut using one of the following methods: a. Best: Circular saw equipped with a HardieBlade® saw blade and attached vacuum dust collection system. Shears (manual, pneumatic or electric) may also be used, not recommended for products thicker than 7/16 in. b. Better: Circular saw equipped with a dust collection feature (e.g. Roan® saw) and a HardieBlade saw blade. c. Good: Circular saw equipped with a HardieBlade saw blade. INDOORS DO NOT grind or cut with a power saw indoors. Cut using shears (manual, pneumatic or electric) or the score and snap method, not recommended for products thicker than 7/16 in. - DO NOT dry sweep dust; use wet dust suppression or vacuum to collect dust. - For maximum dust reduction, James Hardie recommends using the "Best" cutting practices. Always follow the equipment manufacturer's instructions for proper operation. - For best performance when cutting with a circular saw, James Hardie recommends using HardieBlade® saw blades. - Go to jameshardiepros.com for additional cutting and dust control recommendations. IMPORTANT: The Occupational Safety and Health Administration (OSHA) regulates workplace exposure to silica dust. For construction sites, OSHA has deemed that cutting fiber cement with a circular saw having a blade diameter less than 8 inches and connected to a commercially available dust collection system per manufacturer's instructions results in exposures below the OSHA Permissible Exposure Limit (PEL) for respirable crystalline silica, without the need for additional respiratory protection. If you are unsure about how to comply with OSHA silica dust regulations, consult a qualified industrial hygienist or safety professional, or contact your James Hardie technical sales representative for assistance. James Hardie makes no representation or warranty that adopting a particular cutting practice will assure your compliance with OSHA rules or other applicable laws and safety requirements. GENERAL REQUIREMENTS: · HardiePlank® lap siding can be installed over braced wood or steel studs, 20 gauge (33 mils) minimum to 16 gauge (54 mils) maximum, spaced a maximum of 24 in o.c. or directly to minimum 7/16 in thick OSB sheathing. See General Fastening Requirements. Irregularities in framing and sheathing can mirror through the finished application. Correct irregularities before installing siding. · Information on installing James Hardie products over non-nailable substrates (ex: gypsum, foam,etc.) can be located in JH Tech Bulletin 19 at www.jamehardie.com · A water-resistive barrier is required in accordance with local building code requirements. The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap® Weather Barrier, a non-woven non-perforated housewrap¹, which complies with building code requirements. · When installing James Hardie products all clearance details in figs. 3-14 must be followed. · Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum Double Wall Figure 1 Single Wall Construction Construction of 6 in. in the first 10 ft.. · Do not use HardiePlank lap siding in Fascia or Trim applications. · Do not install James Hardie products, such that they may remain in contact with standing water. water-resistive barrier plywood or OSB sheathing let-in bracing 24 in. o.c. max. · HardiePlank lap siding may be installed on flat vertical wall applications only. · For larger projects, including commercial and multi-family projects, where the span of the wall is significant in length, the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin "Expansion Characteristics of James Hardie® Siding Products" at www.jameshardie.com. · James Hardie Building Products provides installation/wind load information for buildings with a maximum mean roof height of 85 feet. For information on installations above 60 feet, please contact JH technical support. INSTALLATION: JOINT TREATMENT One or more of the following joint treatment options are required by code (as referenced 2009 IRC R703.10.2) Figure 2 stud A. Joint Flashing (James Hardie recommended) B. Caulking* (Caulking is not recommended for ColorPlus for aesthetic reasons as the Caulking and ColorPlus will weather differently. For the same reason, joint flashing waterresistive barrier do not caulk nail heads on ColorPlus products.) C. "H" jointer cover Nail line (If nail line is not present, place fastener between 3/4 in. & 1 in. from top of plank) Nail 3/8 in. from edge of plank Install planks in moderate contact at butt joints Leave appropriate gap between planks and trim, then caulk.* Note: Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus. *Refer to Caulking section in these instructions. ¹For additional information on HardieWrap® Weather Barrier, consult James Hardie at 1-866-4Hardie or www.hardiewrap.com water-resistive barrier fastener Install a 1 1/4 in. starter strip to ensure a consistent plank angle SELECT CEDARMILL© | SMOOTH | BEADED CEDARMILL© | BEADED SMOOTH | CUSTOM COLONIAL SMOOTH® | CUSTOM COLONIALTM ROUGHSAWN Visit jameshardiepros.com for the most recent version. HS11119 P1/4 12/19 HardiePlank® Lap Siding CLEARANCE AND FLASHING REQUIREMENTS Figure 3 Roof to Wall Figure 4 Horizontal Flashing Figure 5 Kickout Flashing Figure 6 Slabs, Path, Steps to Siding Z-Flashing Min. 1 in. Figure 7 Deck to Wall Figure 8 Ground to Siding Min. ¼ in. Do not caulk As required by IRC code min 4 in. x 4 in. Figure 9 Figure 10 Gutter to Siding Sheltered Areas Min. 1 in. Figure 11 Mortar/Masonry Z-Flashing Z-Flashing L-Flashing Z-Flashing Min. 1 in. 6 in. 1 in. Min. ¼ in. Min. ½ in. Min. ¼ in. Figure 12 Drip Edge Figure 13 Block Penetration (Recommended in HZ10) Z-Flashing Min. ¼ in. Do not caulk Figure 14 Valley/Shingle Extension Extend shingles at least 1 in. out from the fascia when gutters are present FASTENER REQUIREMENTS* Refer to the applicable ESR report online to determine which fastener meets your wind load design criteria. Blind Nailing is the preferred method of installation for HardiePlank® lap siding products. Face nailing should only be used where required by code for high wind areas and must not be used in conjunction with Blind nailing (Please see JH Tech bulletin 17 for exemption when doing a repair). BLIND NAILING Nails - Wood Framing · Siding nail (0.09 in. shank x 0.221 in. HD x 2 in. long) · 11ga. roofing nail (0.121 in. shank x 0.371 in. HD x 1.25 in. long) FACE NAILING Nails - Wood Framing · 6d (0.113 in. shank x 0.267 in. HD x 2 in. long) · Siding nail (0.09" shank x 0.221" HD x 2" long) Screws - Steel Framing · Ribbed Wafer-head or equivalent (No. 8 x 1 1/4 in. long x 0.375 in. HD) Screws must penetrate 3 threads into metal framing. Screws - Steel Framing · Ribbed Bugle-head or equivalent (No. 8-18 x 1-5/8 in. long x 0.323 in. HD) Screws must penetrate 3 threads into metal framing. Nails - Steel Framing · ET & F Panelfast® nails or equivalent (0.10 in. shank x 0.313 in. HD x 1-1/2 in. long) Nails must penetrate minimum 1/4 in. into metal framing. Nails - Steel Framing · ET & F pin or equivalent (0.10 in. shank x 0.25 in. HD x 1-1/2 in. long) Nails must penetrate minimum 1/4 in. into metal framing. OSB minimum 7/16 in. · Siding nail (0.09 in. shank x 0.215 in. HD x 1-1/2 in. long · Ribbed Wafer-head or equivalent (No. 8 x 1 5/8 in. long x 0.375 in. HD). OSB minimum 7/16 in. · Siding nail (0.09 in. shank x 0.221 in. HD x 1-1/2 in. long) *Also see General Fastening Requirements; and when considering alternative fastening options refer to James Hardie's Technical Bulletin USTB 5 - Fastening Tips for HardiePlank Lap Siding. HS11119 P2/4 12/19 HardiePlank® Lap Siding FASTENER REQUIREMENTS continued Stud 24" O.C. max Nail Line Blind Nail Figure 15 Figure 16 Minimum overlap for Both Face and Blind Nailing min. 1 1/4 in. overlap Stud Joint Flashing 3/4"-1" 24" O.C. max Face Nail 1 1/4" min. Overlap 1 1/4" min. Overlap Water Resistive Barrier Water Resistive Barrier Laminate sheet to be removed immediately after installation of each course for ColorPlus® products. Pin-backed corners may be done for aesthetic purposes only. Finish nails are recommended for pin-backs. Headed siding nails are allowed. Place pin-backs no closer than 1 in. from plank ends and 3/4 in. from plank edge into min. 3/8 in. wood structural panel. Pin-backs are not a substitute for blind or face nailing. GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot-dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie® products near the ocean, large bodies of water, or in very humid climates. Manufacturers of ACQ and CA preservative-treated wood recommend spacer materials or other physical barriers to prevent direct contact of ACQ or CA preservative-treated wood and aluminum products. Fasteners used to attach HardieTrim Tabs to preservative-treated wood shall be of hot dipped zinc-coated galvanized steel or stainless steel and in accordance to 2009 IRC R317.3 or 2009 IBC 2304.9.5 PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a SNUG FLUSH smooth faced hammer - Does not apply for installation to steel framing). DO NOT DO NOT DO NOT USE · Consult applicable product evaluation or listing for correct fasteners type and placement to achieve specified design wind loads. · NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. · Drive fasteners perpendicular to siding and framing. · Fastener heads should fit snug against siding (no air space). · NOTE: Whenever a structural member is present, HardiePlank should be fastened with even spacing to the structural member. The tables allowing direct to OSB or plywood should only be used when traditional framing is not available. CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. James Hardie touch-up kits are required to touch-up ColorPlus products. CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: some caulking manufacturers do not allow "tooling". UNDER DRIVE IF, THEN WOOD FRAME STEEL FRAME HAMMER FLUSH REMOVE & REPLACE OVER DRIVE SLANT IF, THEN ADDITIONAL NAIL FACE NAIL COUNTERSINK & FILL AL ALUMINUM FASTENERS CLIPPED HEAD NAILS STAPLES PAINTING DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. Factory-primed James Hardie products must be painted within 180 days of installation. 100% acrylic topcoats are recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back-rolling is recommended if the siding is sprayed. HS11119 P3/4 12/19 HardiePlank® Lap Siding COLORPLUS® TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE · Care should be taken when handling and cutting James Hardie® ColorPlus® products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. · Touch up nicks, scrapes and nail heads using the ColorPlus® Technology touch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardiePlank® lap siding with ColorPlus® Technology. · Laminate sheet must be removed immediately after installation of each course. · Terminate non-factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus® product dealer. · Treat all other non-factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINTING JAMES HARDIE® SIDING AND TRIM PRODUCTS WITH COLORPLUS® TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: · Ensure the surface is clean, dry, and free of any dust, dirt, or mildew · Repriming is normally not necessary · 100% acrylic topcoats are recommended · DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. · Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature · DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section COVERAGE CHART/ESTIMATING GUIDE Number of 12 ft. planks, does not include waste COVERAGE AREA LESS OSPQENINGS (1 SQ = 100 sq.ft.) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 HARDIEPLANK® LAP SIDING WIDTH 5 1/4 6 1/4 7 1/4 7 1/2 8 8 1/4 9 1/4 9 1/2 12 4 5 6 6 1/4 6 3/4 7 8 8 1/4 10 3/4 25 20 17 16 15 14 13 13 9 50 40 33 32 30 29 25 25 19 75 60 50 48 44 43 38 38 28 100 80 67 64 59 57 50 50 37 125 100 83 80 74 71 63 63 47 150 120 100 96 89 86 75 75 56 175 140 117 112 104 100 88 88 65 200 160 133 128 119 114 100 100 74 225 180 150 144 133 129 113 113 84 250 200 167 160 148 143 125 125 93 275 220 183 176 163 157 138 138 102 300 240 200 192 178 171 150 150 112 325 260 217 208 193 186 163 163 121 350 280 233 224 207 200 175 175 130 375 300 250 240 222 214 188 188 140 400 320 267 256 237 229 200 200 149 425 340 283 272 252 243 213 213 158 450 360 300 288 267 257 225 225 167 475 380 317 304 281 271 238 238 177 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide. Actual usage is subject to variables such as building design. James Hardie does not assume responsibility for over or under ordering of product. HS11119 P4/4 12/19 DANGER: May cause cancer if dust from product is inhaled. Causes damage to lungs and respiratory system through prolonged or repeated inhalation of dust from product. Refer to the current product Safety Data Sheet before use. The hazard associated with fiber cement arises from crystalline silica present in the dust generated by activities such as cutting, machining, drilling, routing, sawing, crushing, or otherwise abrading fiber cement, and when cleaning up, disposing of or moving the dust. When doing any of these activities in a manner that generates dust you must (1) comply with the OSHA standard for silica dust and/or other applicable law, (2) follow James Hardie cutting instructions to reduce or limit the release of dust; (3) warn others in the area to avoid breathing the dust; (4) when using mechanical saw or high speed cutting tools, work outdoors and use dust collection equipment; and (5) if no other dust controls are available, wear a dust mask or respirator that meets NIOSH requirements (e.g. N-95 dust mask). During clean-up, use a well maintained vacuum and filter appropriate for capturing fine (respirable) dust or use wet clean-up methods - never dry sweep. SILICA WARNING WARNING: This product can expose you to chemicals including respirable crystalline silica, which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov. RECOGNITION: I In accordance with ICC-ES Evaluation Report ESR-2290, HardiePlank® lap siding is recognized as a suitable alternate to that specified in the 2006, 2009, 2012 & 2015 International Residential Code for One and Two-Family Dwellings, and the 2006, 2009, 2012 & 2015 International Building Code. HardiePlank lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida Product Approval FL#13192, Miami-Dade County Florida NOA No. 17-0406.06, U.S. Dept. of HUD Materials Release 1263f, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications. © 2018 James Hardie Building Products, Inc. All rights reserved TM, SM and ® denote trademarks or registered trademarks of James Hardie Technology Limited. Product warranties, safety information and additional installation information are available at jameshardiepros.com