| DC busbar overvoltage protection | Bright | Blink | Bright | Bright | Bright | Bright | E5 |
| Radiating fin overheat protection | Bright | Blink | Bright | Bright | Bright | Blink | E5 |
| Current sensor fault | Bright | Blink | Bright | Bright | Blink | Bright | E5 |
| Radiator sensor fault | Bright | Blink | Bright | Blink | Bright | Bright | E5 |
| Compressor current protection | Bright | Blink | Bright | Blink | Bright | Blink | E5 |
| DC busbar under voltage protection | Bright | Blink | Bright | Blink | Blink | Bright | E5 |
| Compressor startup failure | Bright | Blink | Dark | Bright | Bright | Bright | E5 |
| PFC abnormal | Bright | Blink | Dark | Bright | Bright | Dark | E5 |
| Compressor clogged | Bright | Blink | Dark | Bright | Bright | Blink | E5 |
| Drive resetting | Bright | Blink | Dark | Bright | Dark | Bright | E5 |
| The compressor motor in loss of synchronization | Bright | Blink | Dark | Bright | Dark | Dark | E5 |
| Driver board in open phase | Bright | Blink | Dark | Bright | Dark | Blink | E5 |
| Fault from variable frequency drive to main control communication | Bright | Bright | Dark | Dark | Dark | Blink | E5 |
| IPM module protection | Bright | Blink | Blink | Bright | Bright | Bright | E5 |
| Compressor over speed | Bright | Blink | Blink | Bright | Bright | Dark | E5 |
| Sensor connection protection | Bright | Blink | Blink | Bright | Bright | Blink | E5 |
| Temperature drift protection | Bright | Blink | Blink | Bright | Dark | Bright | E5 |
| AC contactor protection | Bright | Blink | Blink | Bright | Dark | Dark | E5 |
| AC current protection (input side) | Bright | Blink | Bright | Blink | Bright | Dark | E5 |
| Driver board environment temperature sensor error | Bright | Blink | Bright | Blink | Dark | Bright | E5 |
| High-pressure protection | Bright | Blink | Dark | Dark | Dark | Blink | E1 |
| Low-pressure protection | Bright | Blink | Dark | Dark | Blink | Dark | E3 |
| Exhaust protection | Bright | Blink | Dark | Dark | Blink | Blink | E4 |
| Compressor overload protection | Bright | Blink | Dark | Blink | Dark | Dark | E5 |
| Communication error(between indoor / outdoor unit and wired controller) | Bright | Blink | Dark | Blink | Blink | Dark | E6 |
| Outdoor environment temperature sensor error | Bright | Blink | Blink | Dark | Dark | Dark | F3 |
| Indoor coil middle temperature sensor error | Bright | Blink | Blink | Dark | Blink | Dark | F2 |
| Variable-frequency exhaust temperature sensor error | Bright | Blink | Blink | Blink | Dark | Blink | F4 |
| Defrost (non-malfunction) | Bright | Blink | Dark | Blink | Blink | Blink | Defrost |
| Oil return (non-malfunction) | Bright | Blink | Blink | Blink | Bright | Blink | No display |
| Mismatch of indoor unit model | Bright | Blink | Dark | Blink | Bright | Blink | No display |