Owner's Manual for MEAN WELL models including: GSM40A05-P1J, GSM40A07-P1J, GSM40A09-P1J, GSM40A12-P1J, GSM40A15-P1J, GSM40A18-P1J, GSM40A24-P1J, GSM40A48-P1J, GSM40A05-P1J 40W AC-DC Reliable Green Medical Adaptor, GSM40A05-P1J, 40W AC-DC Reliable Green Medical Adaptor, Reliable Green Medical Adaptor, Green Medical Adaptor, Medical Adaptor
File Info : application/pdf, 5 Pages, 970.59KB
DocumentDocument40W AC-DC Reliable Green Medical Adaptor GSM40A series User's Manual Video ( for 5~9V) ++ Features https://www.meanwell.com/serviceGTIN.aspx https://www.meanwell.com/upload/pdf/DC_plug.pdf Description I , - . * ), . , , . . . . { File Name:GSM40A-SPEC 2025-01-20 40W AC-DC Reliable Green Medical Adaptor GSM40A series SPECIFICATION ORDER NO. GSM40A05-P1J GSM40A07-P1J GSM40A09-P1J GSM40A12-P1J GSM40A15-P1J GSM40A18-P1J GSM40A24-P1J GSM40A48-P1J SAFETY MODEL NO. GSM40A05 GSM40A07 GSM40A09 GSM40A12 GSM40A15 GSM40A18 GSM40A24 GSM40A48 DC VOLTAGE Note.2 5V 7.5V 9V 12V 15V 18V 24V 48V RATED CURRENT 5A 5.34A 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A CURRENT RANGE 0.1 ~ 5A 0.1 ~ 5.34A 0.1 ~ 4.45A 0.1 ~ 3.34A 0.1 ~ 2.67A 0.1 ~ 2.22A 0.1 ~ 1.67A 0.1 ~ 0.84A RATED POWER (max.) 25W 40W 40W 40W 40W 40W 40W 40W OUTPUT RIPPLE & NOISE (max.) Note.3 80mVp-p 80mVp-p 100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5% SETUP, RISE TIME Note.6 1000ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) 50ms / 230VAC VOLTAGE RANGE Note.7 80 ~ 264VAC 24ms / 115VAC at full load FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 81% 85.5% 86% 88% 88.5% 89.5% 90% 91% AC CURRENT (Typ.) 1A / 115VAC 0.5A / 230VAC INRUSH CURRENT (Typ.) Cold start 30A/115VAC 60A / 230VAC LEAKAGE CURRENT(max.) Earth leakage current < 90A/264VAC , Touch current < 90A/264VAC OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.2 ~ 7.0V 7.8 ~ 10.2V 9.4 ~ 12.2V 12.6 ~ 16.2V 15.7 ~ 20.3V 18.9 ~ 24.3V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 25.2 ~ 32.4V 50.4 ~ 64.8V WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 20% ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing ±0.03% / (0~50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.8 3000 meters SAFETY STANDARDS IEC 60601-1:2005+A1+A2, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2,CAN/CSA C22.2 No. 60601-1:2014+A2, EAC TP TC 004 approved ISOLATION LEVEL Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT ISOLATION RESISTANCE I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH Parameter Standard Test Level / Note Conducted emission BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) Class B EMC EMISSION Radiated emission BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) Class B Harmonic current BS EN/EN61000-3-2 Class A SAFETY & EMC (Note 9) EMC IMMUNITY Voltage flicker BS EN/EN61000-3-3 BS EN/EN60601-1-2, BS EN/EN61204-3 Parameter Standard ESD BS EN/EN61000-4-2 RF field susceptibility BS EN/EN61000-4-3 EFT bursts Surge susceptibility Conducted susceptibility Magnetic field immunity BS EN/EN61000-4-4 BS EN/EN61000-4-5 BS EN/EN61000-4-6 BS EN/EN61000-4-8 ----- Test Level / Note Level 4, 15KV air ; Level 4, 8KV contact Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) Level 3, 2KV Level 3, 1KV/Line-Line , 2KV/Line-FG Level 3, 10V Level 4, 30A/m Voltage dip, interruption BS EN/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods OTHERS CONNECTOR NOTE MTBF 3613.2K hrs min. Telcordia SR-332 (Bellcore) ; 740.7K hrs min. MIL-HDBK-217F (25) DIMENSION 125*50*31.5mm (L*W*H) PACKING 0.25Kg; 40pcs/ 12Kg/1.04CUFT PLUG See page 4~5 ; Other type available by customer requested CABLE See page 4~5 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1F & 47F capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltages. Pleas check the derating curve for more details. 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) https://www.meanwell.com/serviceDisclaimer.aspx File Name:GSM40A-SPEC 2025-01-20 40W AC-DC Reliable Green Medical Adaptor GSM40A series Derating Curve Static Characteristics 100 80 60 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 80 90 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz LOAD (%) 50 LOAD (%) Mechanical Specification (Unit: mm , tolerance ± 1mm) 31.5 125 Power LED Case No. GS60A UL2464 16AWG 1000±50mm for 5 ~ 7.5V UL1185 16AWG 1000±50mm for 9 ~ 12V UL1185 16AWG 1500±50mm for 15 ~ 48V 70±10mm AC Inlet IEC320-C14 DC output plug Standard plug: P1J P1J 5.5 2.1 11±0.5mm Pin Assignment C"+" Outside Inside -V connected to AC FG(standard) -V not connected to AC FG(optional) File Name:GSM40A-SPEC 2025-01-20 40W AC-DC Reliable Green Medical Adaptor GSM40A series DC plug changeable through: (1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable) (2) Quick adapter accessory (sold separately without MOQ) Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf Example quick adapter accessory: Optional DC plug: (Available in customized cable or quick adapter) Tuning Fork Style Type No. A B Barrel Style C (Straight) C (Right-angled) P1I P1L P1M P1IR P1JR P1LR P1MR Type No. C P2I P2J P2L A (Straight) P2M B C P2IR P2JR (Right-angled) P2LR P2MR Lock Style Type No. A Floating Locking C P2S(S761K) P2K(761K) B P2C(S760K) SWITCHCRAFT original or equivalent P2D(760K) Min. Pin Style Type No. A C P3A B EIAJ equivalent P3B P3C Center Pin Style Type No. A C P4A B P4B D EIAJ equivalent P4C A OD 5.5 5.5 5.5 5.5 5.5 5.5 5.5 A OD 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 A OD 5.53 5.53 5.53 5.53 A OD 2.35 4.0 4.75 A OD 5.5 6.5 7.4 B ID 2.1 2.5 2.5 2.1 2.1 2.5 2.5 B ID 2.1 2.1 2.5 2.5 2.1 2.1 2.5 2.5 B ID 2.03 2.54 2.03 2.54 B ID 0.7 1.7 1.7 BC ID L 3.4 11.0 4.4 11.0 5.1 11.0 C L 9.5 9.5 11.0 9.5 11.0 9.5 11.0 C L 9.5 11.0 9.5 11.0 9.5 11.0 9.5 11.0 C L 12.06 12.06 9.52 9.52 C L 11.0 11.0 Quick Adapter Accessory Available (Current rating: 7.5A max.) None None Available (Current rating: 5A max.) 11.0 D Center Pin 1.0 1.4 Available (Current rating: 7.5A max.) 0.6 File Name:GSM40A-SPEC 2025-01-20 40W AC-DC Reliable Green Medical Adaptor GSM40A series Min. DIN 3 Pin with Lock (male) 1 3 2 KYCON KPPX-3P equivalent Min. DIN 4 Pin with Lock (male) 23 14 KYCON KPPX-4P equivalent Min. DIN 4 Pin with Lock (female) 23 14 KYCON KPJX-CM-4S equivalent DIN 5 Pin (male) 13 425 Stripped and tinned leads Type No. R6B Type No. R7B Type No. R7BF Type No. R1B Type No. Pin Assignment PIN No. Output 1 +Vo 2 -Vo 3 +Vo Pin Assignment PIN No. Output 1 +Vo 2 -Vo 3 -Vo 4 +Vo Pin Assignment PIN No. Output 1 +Vo 2 -Vo 3 -Vo 4 +Vo Pin Assignment PIN No. Output 1 -Vo 2 -Vo 3 +Vo 4 -Vo 5 +Vo Pin Assignment PIN No. Output L (red) 1 2 1 +Vo L1 (black) by customer Length of Land L1 by request (MW's standard length, L: 25 mm, L1: 5 mm) ( NOTE: The wire color is for reference only, please refer to the actual product) 2 -Vo Quick Adapter Accessory Available (Current rating: 7.5A max.) Available (Current rating: 7.5A max.) None Available (Current rating: 7.5A max.) None Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:GSM40A-SPEC 2025-01-20